NetBootLoader
VMP2
Page 5 - 26
© 2002 PEP Modular Computers GmbH
ID 24855, Rev. 02
DESCRIPTION:
To set or display the operational parameters for the available serial in-
terfaces the command “pf” is used.
At startup the settings for the “TERM” and “SER0” interfaces are al-
ways set to the default values (9600/8/n/1). This is to avoid a possible
system lockout. If other settings are required during operation of the
NetBootLoader they may be made. If changes are made, it must be
ensured that corresponding parameters are used for the operator con-
sle.
Issuing this command without parameters being specified will display
the current serial port settings.
Syntax-wise, no spaces are permitted between the parameters and
they must be separated with a slash. Not all parameters must be
specified, but the “/” characters must be present to distinguish the
different parameters from each other. The sequence can be aborted
after every option.
USAGE:
Set “TERM” to 300 Baud, 7 Bits/char, odd parity, and 2 stop bits
COMMAND / RESPONSE (none):
pf term 300/7/o/2
Set the bits per character parameter of “SER0” to 7
COMMAND / RESPONSE (none):
pf ser0 //7
Set the stop bits parameter of “SER0” to 2
COMMAND / RESPONSE (none):
pf ser0 ///2
P F
StockCheck.com