background image

CP341

Preface

Two Years Warranty

PEP Modular Computers

 grants the original purchaser of 

PEP

 products a

 

TWO

 

YEARS

 

LIMITED

HARDWARE

 

WARRANTY

 

as described in the following. However, no other warranties that may be

granted or implied by anyone on behalf of 

PEP

 are valid unless the consumer has the express

written consent of 

PEP Modular Computers

.

PEP Modular Computers

 warrants their own products, excluding software, to be free from

manufacturing and material defects for a period of 24 consecutive months from the date of
purchase. This warranty is not transferable nor extendible to cover any other users or long-
term storage of the product. It does not cover products which have been modified, altered or
repaired by any other party than 

PEP Modular Computers

 or their authorized agents. Further-

more, any product which has been, or is suspected of being damaged as a result of negli-
gence, improper use, incorrect handling, servicing or maintenance, or which has been
damaged as a result of excessive current/voltage or temperature, or which  has had its serial
number(s), any other markings or parts thereof altered, defaced or removed will also be
excluded from this warranty.

If the customer’s eligibility for warranty has not been voided, in the event of any claim, he may
return the product at the earliest possible convenience to the original place of purchase,
together with a copy of the original document of purchase, a full description of the application
the product is used on and a description of the defect. Pack the product in such a way as to
ensure safe transportation (see our safety instructions).

PEP

 provides for repair or replacement of any part, assembly or sub-assembly at their own

discretion, or to refund the original cost of purchase, if appropriate. In the event of repair,
refunding or replacement of any part, the ownership of the removed or replaced parts reverts
to 

PEP Modular Computers

, and the remaining part of the original guarantee, or any new

guarantee to cover the repaired or replaced items, will be transferred to cover the new or
repaired items. Any extensions to the original guarantee are considered gestures of goodwill,
and will be defined in the “Repair Report” issued by 

PEP

 with the repaired or replaced item.

PEP Modular Computers

 will not accept liability for any further claims resulting directly or indi-

rectly from any warranty claim, other than the above specified repair, replacement or refund-
ing. In particular, all claims for damage to any system or process in which the product was
employed, or any loss incurred as a result of the product not functioning at any given time, are
excluded. The extent of 

PEP Modular Computers

 liability to the customer shall not exceed the

original purchase price of the item for which the claim exists.

PEP Modular Computers

 issues no warranty or representation, either explicit or implicit, with

respect to its products’ reliability, fitness, quality, marketability or ability to fulfil any particular
application or purpose. As a result, the products are sold “as is,” and the responsibility to
ensure their suitability for any given task remains that of the purchaser. In no event will 

PEP

be liable for direct, indirect or consequential damages resulting from the use of our hardware
or software products, or documentation, even if PEP were advised of the possibility of such
claims prior to the purchase of the product or during any period since the date of its purchase.

Please remember that no 

PEP Modular Computers

 employee, dealer or agent is authorized to

make any modification or addition to the above specified  terms, either verbally or in any other
form, written or electronically transmitted, without the company’s consent.

ID 18845, Rev. 0102

Page 0 - 8

® 

PEP Modular Computers GmbH

Содержание CP341

Страница 1: ...CP341 Dual Port Ethernet Fast Ethernet Board for CompactPCI Applications Manual ID 18845 Rev Index 0102 20 Nov 98 The product described in this manual is in compliance with all applied CE stan dards ...

Страница 2: ... PEP Modular Computers GmbH This page was intentionally left blank ...

Страница 3: ...planation of Symbols 0 5 For Your Safety 0 6 High Voltage Safety Instructions 0 6 Special Handling and Unpacking Instructions 0 6 General Instructions on Usage 0 7 Two Years Warranty 0 8 Table of Contents 0 9 ID 18845 Rev 0102 Page 0 3 PEP Modular Computers GmbH ...

Страница 4: ...own in this document PEP Modular Computers reserve the right to change modify or improve this document or the product described herein as seen fit by PEP Modular Computers without further notice Trademarks PEP Modular Computers the PEP logo and CXM are trade marks owned by PEP Modular Computers GmbH Kaufbeuren Germany In addition this document may include names company logos and trademarks which a...

Страница 5: ...that electronic boards and their components are sensitive to static electricity There fore care must be taken during all handling operations and inspections of this product in order to ensure product integ rity at all times Please read also the section Special Handling and Unpack ing Instructions of this manual Attention This symbol and title emphasize aspects which if not read through carefully b...

Страница 6: ...y done by touching a metal part of your system housing It is particularly important to observe standard anti static precautions when changing piggybacks ROM devices jumper settings etc If the product contains batteries for RTC or memory back up ensure that the board is not placed on conductive surfaces includ ing anti static plastics or sponges They can cause short circuits and damage the batter i...

Страница 7: ...e operational temperature range of the specific board version which must not be exceeded If batter ies are present their temperature restrictions must be taken into account In performing all necessary installation and application operations please follow only the instructions supplied by the present manual Keep all the original packaging material for future storage or warranty shipments If it is n...

Страница 8: ...ent of repair refunding or replacement of any part the ownership of the removed or replaced parts reverts to PEP Modular Computers and the remaining part of the original guarantee or any new guarantee to cover the repaired or replaced items will be transferred to cover the new or repaired items Any extensions to the original guarantee are considered gestures of goodwill and will be defined in the ...

Страница 9: ...m Overview 1 3 1 2 System Components 1 4 1 3 Board Introduction 1 7 1 4 Board Overview 1 7 1 5 Main Features 1 8 1 6 Main Features 1 10 1 7 Applied Standards 1 11 1 8 Related Publications 1 11 Chapter 2 2 Configuration 2 3 Chapter 3 3 Installation 3 3 3 1 Hardware Installation 3 3 3 2 Driver Installation 3 5 3 3 Troubleshooting 3 7 ...

Страница 10: ... PEP Modular Computers GmbH This page was intentionally left blank ...

Страница 11: ...tems 1 3 1 2 System Components 1 4 1 3 Board Introduction 1 7 1 4 Board Overview 1 7 1 5 Main Features 1 8 1 5 1 LAN Controller 1 8 1 5 2 Memory 1 8 1 5 3 Board Interfaces 1 8 1 5 4 Front Panel 1 9 1 6 Specifications 1 10 1 7 Applied Standards 1 11 1 7 1 CE Compliance 1 11 1 7 2 Mechanical Compliance 1 11 1 7 3 Environmental Tests 1 11 1 8 Related Publications 1 11 Chapter 1 ...

Страница 12: ... PEP Modular Computers GmbH This page was intentionally left blank ...

Страница 13: ... has been optimized for industrial and or embedded applications that require a more robust mechanical form factor as compared to Desktop PCI CompactPCI systems use industry standard mechanical components and high performance connector technologies to provide systems that are well suited for rugged applications CompactPCI stands for systems that are electrically compatible with the PCI Specificatio...

Страница 14: ...bing are supported by dedicated boards Communication Communication boards are provided for the currently relevant industrial communication systems such as for instance Fast Ethernet Fieldbus Control Fieldbus control boards provide data exchange with field control and automation sub systems like for example PEP Modular Computers SMART2 or VMEbus systems using up to date transmission standards e g C...

Страница 15: ... wall mounting PCI tower PCI desktop housing Mass Storage Devices Hard disk drive Floppy disk drive CD ROM drive Power Supply Units 19 inch M 180 W 120 230 V AC 3 3V 14A 5 1V 20A 12V 2A 12V 1A ATX 235 W 120 230 VAC 3 3V 14A 5V 22A 12V 8A 12V 1A 5V 0 5A 5VSB 0 1A Please note that the following units of measurement are used to express the dimensions of PEP cards and housings Height 1 U 44 45 mm Widt...

Страница 16: ...pactPCI System Image Control WD Timer HDD FDD CD ROM COM LPT Keyboard SMART2 SMART I O PEP9300 Host Computer CompactPCI Workstation W W W CPU Server Computer Fast Ethernet VGA LVDS Graphics F Ethernet Communic RGB SYNC Industrial I O Digital I O Analog I O CPCI Backplane Fieldbus PROFIBUS CAN Host Computer Multi Processor ...

Страница 17: ...d includes all necessary features for auto negotiation Thus both 10 Mbit s and 100 Mbit s transfer rates are supported by the board In fact provided that your net work has the speed capability the CP341 switches automatically from 10 Mbit s to 100 M bit s Additionally if the addressed network station is compatible it switches automat ically to full duplex mode The 3 3V 5V signalling board is desig...

Страница 18: ...ernet networks It is characterized by advanced control features for high performance and outstanding reliability 1 5 2 Memory The board conception includes hardware support for an optional FLASH memory up to two times 64 kByte 1 5 3 Board Interfaces Figure 1 3 RJ45 Ethernet Fast Ethernet Connector The CP341 is provided principally with two RJ45 network communication connectors for Ethernet or Fast...

Страница 19: ...o magnetic interference between cable wires 1 5 4 Front Panel Figure 1 4 CP341 Front Panel View The CP341 front panel is provided with two Ethernet Fast Ethernet RJ45 LAN connectors while three control LEDs are associated with each of them in order to allow monitoring the board activity The LEDs have the following functions LINK ON LAN link is integer ACT ON board is active SPEED ON transfer speed...

Страница 20: ...lose to 132 MByte s 1 4TE slot Signalling Voltage 3 3V 5 V Plug Play Design No jumpers to be configurated Remote Boot 2 x EEPROM FLASH socket 64 kByte max each Speed Configuration Auto speed sensing switching Wake up on LAN Remote Wake up Package detection logics reacting on incoming packages Front Panel Connector 2 x RJ 45 with 2 pair 5 UTP STP cable pinout each Mechanical Compliance IEEE 1101 10...

Страница 21: ...ements of the following CE relevant standards Emission EN50081 1 Immission EN50082 2 Electrical Safety EN60950 1 7 2 Mechanical Compliance Mechanical Dimensions IEEE 1101 10 1 7 3 Environmental Tests Vibrations Broad Band IEC68 2 6 Random Vibration IEC68 2 64 3U boards Permanent Shocks IEC68 2 29 Single Shock IEC68 2 27 1 8 Related Publications CompactPCI Specification V 2 0 Rev 2 1 ...

Страница 22: ... PEP Modular Computers GmbH This page was intentionally left blank ...

Страница 23: ...CP341 ID 18845 Rev 0102 Configuration Page 2 1 PEP Modular Computers GmbH Configuration Chapter 2 ...

Страница 24: ... PEP Modular Computers GmbH This page was intentionally left blank ...

Страница 25: ...tion A complete set of drivers is located on the PEP Modular Computers Drivers disk supplied with the CP341 Simply insert the cable terminal into the CP341 Ethernet Fast Ethernet RJ 45 socket run the automatic configuration software install the network drivers and it s ready Important Useful hints on driver installation and configuration of the CP341 board via software as well as the relevant trou...

Страница 26: ... PEP Modular Computers GmbH This page was intentionally left blank ...

Страница 27: ...ons 3 3 3 1 2 Board Placement 3 3 3 1 3 Board Installation 3 4 3 1 4 Board Connection 3 4 3 1 5 AC Power Connection 3 5 3 2 Software Installation 3 5 3 2 1 Automatic Configuration 3 5 3 2 2 Installation of Network Drivers 3 5 3 2 3 Configuration Utility PROSET 3 6 3 2 4 Adapter Fault Tolerance Mode 3 7 3 3 Troubleshooting 3 7 Chapter 3 ...

Страница 28: ... PEP Modular Computers GmbH This page was intentionally left blank ...

Страница 29: ...cation for the unit which will house your CP341 the following factors must be considered length of each cable connection between devices environmental factors Distance between Devices If your network connections consist of twisted pair connections the maximum distance between devices is 100 meters 328 feet Using this cable type the maximum length of cabling between any two end nodes including any ...

Страница 30: ...d as hot swap capable please switch off the CompactPCI system before installing the board in a free CompactPCI slot Failure to do so could endanger your life health and may damage your board or system Note Certain CompactPCI boards require bus master and or rear I O capability If you are in doubt whether such features are required for the board you intend to install please check your specific boar...

Страница 31: ...t by BIOS each time you start your system Thus for configuring your computer after having mounted the CP341 board just boot it Configuration is complete when Windows NT starts or the DOS prompt appears 3 2 2 Installation of Network Drivers After having inserted your CP341 board into the CompactPCI backplane and started Windows NT you need to install the Intel board drivers and test your CP341 boar...

Страница 32: ...tics are available only while the drivers are not loaded i e before restarting your computer Driver diagnostics are available when the drivers are loaded 3 2 3 Configuration Utility PROSET PROSet is an enhanced utility you can use to easily configure and test your CP341 board in Windows NT PROSet also displays the computer s resources that were assigned to each CP341 interface board installed Figu...

Страница 33: ... AFT enables you to maintain uninterrupted network performance AFT is implemented with two Ethernet adapters a primary adapter and a backup or secondary adapter During normal operation the backup will have transmit disabled If the link to the primary adapter fails the link to the backup adapter automatically takes over 3 3 Troubleshooting Further information on troubleshooting is available on the ...

Страница 34: ... PEP Modular Computers GmbH This page was intentionally left blank ...

Отзывы: