background image

80 

 

 

8.1.6 Arc-Arc intersection  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
Two intersection points of two arcs drawn by each center point and radius are calculated.  
You can store two possible intersection points.  
 
Input:  Arc 1: Center point and Radius  

Arc 2: Center point and Rradius  

Output: Two possible intersection points  
 
 
 
From the PowerTopoLite screen, press [F2]     
[CALC] to view the CALCULATION screen.  
 
 
 
 
 
Select 1.COGO and press [ENT] to view the COGO 
screen.  
  
 
 
 
 
 
Select the 6. ARC-ARC INTERSECTION and press 
[ENT] to view ARC-ARC INTERSECTION screen.  
 
 
 
 

Center 2 

Point 

Radius 2 

Radius 1 

Point 2 

Arc 2 

Arc 1 

Center 1 

Содержание R-422VN

Страница 1: ...ite for R 400V Series R 422VN R 423VN R 425VN R 435VN TI Asahi Co Ltd International Sales Department 3F AUM Bldg 3 37 14 Hazawa Nerima Ku Tokyo Japan 176 0003 Tel 81 3 5912 7072 Fax 81 3 5912 7074 E m...

Страница 2: ...Selection of a Job name 15 3 3 1 Selection of a Job 15 3 3 2 Selection by Job name input 15 3 4 Deletion of a Job name 16 3 4 1 Deletion from a Job list 16 3 4 2 Deletion from a Job name search 17 3...

Страница 3: ...ints 48 7 STAKE OUT 51 7 1 Stake Out 51 7 2 Point to Line 56 7 3 Point to Arc 58 7 3 1 Three points 62 7 3 2 Circle radius 64 8 CALCULATIONS 66 8 1 Cogo 66 8 1 1 Inverse 67 8 1 2 Point Coordinates 70...

Страница 4: ...tion with USB 119 12 3 Communication with COM 120 12 3 1 Input from the PC 120 12 3 2 Output to the PC 121 12 3 3 Communication setup 122 12 3 3 1 Receiving data setting 122 12 3 3 2 Sending data sett...

Страница 5: ...operation incurred by the use of this product or malfunction of it 3 TIA shall not be liable for damage caused by usage not explained in the instruction manual 4 TIA shall not be liable for damage to...

Страница 6: ...le on and off ENT Accepts the selected highlighted choice or the displayed screen value LASER Displays the laser plummet and the LD point screen when you push the Laser key Alphanumeric At the numeric...

Страница 7: ...the screen RETICLE F3 Changes the reticle illumination when pressing illumination key LCD F4 Changes the LCD contrast when pressing illumination key ILLU F5 Changes the LCD illumination when pressing...

Страница 8: ...de B is switched by pressing F5 MODE ALPHANUMERIC INPUT The point name etc is input by the alphanumeric keys as following Key Letter under key Letter figure order to input 0 0 1 PQRS P Q R S p q r s 1...

Страница 9: ...loped based on PowerTopo which is known as a versatile on board software for PENTAX ATS Series Total Stations The optimum combination of PowerTopoLite and R 400V hardware makes PowerTopoLite an easy a...

Страница 10: ...s between the Memory and each Function Function Read from the stored data Write to the stored data Measure SP BSP SP BSP FP SD Stake Out SP BSP SOP SP BSP SOP OP Point to Line SP BSP KP1 KP2 SP BSP KP...

Страница 11: ...r IH and you can input your desired attributes for the point If you have PointCodeList in the job named PointCodeList you can easily select one of the PointCode from the list or edit one of them after...

Страница 12: ...werTopoLite perform the following procedures Press the POWER ON OFF key to view the R 400V start up screen Then change to MODE A screen Press the F5 MODE to view MODE B screen Press F1 S FUNC to view...

Страница 13: ...Functions are viewed by pressing F5 PAGE KEY Function Description F1 TRAV Traverse F3 I O Input and Output F4 PREF Preference INVERSE POINT COORDINATES LINE LINE INTERSECTION functions CALCULATION sc...

Страница 14: ...ng the offset values STATION Returns to the STATION POINT SETUP screen H ANGLE Returns to the STATION POINT H ANGLE SETUP screen LIST Views the POINT SELECTION FROM THE LIST screen OTHER Views the JOB...

Страница 15: ...availability and a JOB Name PENTAX are viewed on the screen The Job name PENTAX and COGOPoint are a default setting NOTE Data being used in COGO will be updated in COGOPoint file from time to time Fo...

Страница 16: ...ct 1 JOB LIST SEARCH and press ENT to view its screen JOB LIST is a list of all stored Jobs Select your desired Job Name and press ENT to select 3 3 2 Selection by a Job Name input Select 2 JOB NAME S...

Страница 17: ...s 3 4 Deletion of a Job Name Select 4 DELETE by pressing the down arrow key Press ENT to view the JOB DELETION screen 3 4 1 Deletion from a Job List Select 1 JOB LIST SEARCH and Press ENT to view its...

Страница 18: ...ENT to view its screen Warning When CLEAR is pushed all Job Files are deleted NOTE Creating several new JOB Files and writing in or rewriting data on the same JOB Files repeatedly may cause the time...

Страница 19: ...int Measurement is possible and the Remote Measurement by aiming at any point is possible as well when you select the Rectangular Coordinates An operator can perform the MEASURE function only when the...

Страница 20: ...is used to scroll up down 6 PC is viewed by scrolling down 4 1 1 Point Name input Select 1 PN to display the PN input screen ENT is used for both accepting the selected choice and opening the input s...

Страница 21: ...ew the Y coordinate input screen Input your desired Y coordinate value by pressing keys Z coordinate Press ENT to view the Z coordinate input screen Input your desired Z coordinate value by pressing k...

Страница 22: ...lection it is necessary to press ACCEPT to proceed to next panel 4 1 3 Point selection from the list Inputting coordinate information can be done manually and also by calling known points Press F2 LIS...

Страница 23: ...ord enables you to list point data with PN including a string after For instance if you need to search a point including P1 in PN input P1 in the key word then press ENT Select the point from the list...

Страница 24: ...s obtained Press ENT to finalize input Press ENT or F5 ACCEPT to view the AIM AT THE REFERENCE POINT screen Press F5 ENT to finalize BSP Press F1 ESC to redo input If you want to make measure to check...

Страница 25: ...ocedure as mentioned in 4 2 Station Orientation will proceed Press F3 MEAS to go to BSP CONFIRM Pressing F5 ENT takes you to DESIGN DISPLAY Designed Data the present angle according to the first orien...

Страница 26: ...ode Input your desired Point Name Prism Height and Point Code Press F5 ACCEPT if the current PN PH and PC are acceptable If Point Code exists you can easily select them from the list or edit one of th...

Страница 27: ...is key again to measure your desired point Coordinates by moving the telescope The displayed Coordinates automatically change according to your aiming point The Remote is a function of so to speak Rea...

Страница 28: ...sing keys VO DO and TO values are input in the same manner After input TO value press ENT to view the MEASURE screen Or press ESC then press ACCEPT The offset values are added to X Y and Z values The...

Страница 29: ...ong the third axis DO Distance Offset Along the line of measurement thus along the slope TO Tangential offset TO On the horizontal plane perpendicular to the horizontal line between Station and Point...

Страница 30: ...ection that R 400V is facing Deviation represents deviation of Calculated Data If you accidentally move the instrument during the measurement the amount of error can be checked on this screen If the i...

Страница 31: ...Input the PC Press ENT to view and input the PC Point Code screen If Point Code exists you can easily select it from the list or edit one of them after pressing ENT For using Point Code List please re...

Страница 32: ...the rotation setting of Coordinate axis definition INVERS key If you want to calculate direction angle Press F5 INVERS to jump to INVERSE function Input SP as Station Point EP as Back Sight Point Resu...

Страница 33: ...sm Height and PC Point Code Press ENT to view each input window by pressing up or down arrow key and input your desired point name or prism height or point code Press F5 ACCEPT if the current PN PH an...

Страница 34: ...OFFSET to view the OFFSET screen Offset enables you to work with Offset The following Offsets are available Press ENT to view the offset input window Input the RO offset value by pressing each keys DO...

Страница 35: ...n be stored at the same time in this function Press F2 MEAS of the PowerTopoLite to view the MEASURE METHOD SELECTION screen Select 3 RECT _POLAR COORD and press ENT to view the STATION POINT SETUP sc...

Страница 36: ...first can be set within PREFERENCE of 11 MEAS DISPLAY In default ANG DIST screen is displayed For more details refer to 13 11 Meas Display Coordinates display and Angle Distance display Aim at the Ref...

Страница 37: ...input the PC Point code screen If Point Code exists you can easily select them from the list or edit one of them after pressing ENT For using PointCodeList please refer to 5 4 1 Point Code Pressing F...

Страница 38: ...essing F1 EDM For example change 1 PRIM MEAS KEY MEAS to TRACK SHOT or TRACK CONT if you want to use tracking measurement with PRIM MEAS KEY MEAS The target type can be selected by pressing F2 TARGET...

Страница 39: ...F2 MEAS of the PowerTopoLite to view the MEASURE METHOD SELECTION screen Select 4 IH MEASURE and press ENT to view the STATION POINT SETUP screen Press ENT to open the PN X Y and Z input window and i...

Страница 40: ...ntCodeList For more details of PointCodeList refer to 5 4 1 Point Code 5 1 Graphical View From the PowerTopoLite screen press F3 VIEW to view its screen Press ENT to view the GRAPHICAL VIEW screen Poi...

Страница 41: ...points The first line of the screen shows now displayed point and the total number of points Press F1 DELETE to delete your desired point Press F2 FIND PN to find your desired point by the PN input N...

Страница 42: ...key press ENT to view the POLAR DATA EDIT screen to edit You can edit data and save it 5 4 Point Code List Select 5 POINT CODE LIST and press ENT to view the POINT CODE LIST screen 5 4 1 Point Code T...

Страница 43: ...is contained in the R 400V Supplement Disk for the format Please note that the newly entered PointCode on the instrument is not added to the PointCodeList that is stored in the memory In this case ed...

Страница 44: ...heck the communication setting select 4 COMMUNICATION SETUP in the TRANSFER screen and press ENT to view COMM SETTING SELECTION screen Then select 1 RECEIVE RECT DATA and set 1 BAUD RATE to 1200 6 XON...

Страница 45: ...44 5 4 3 PointCode Edit Select 2 PointCode Edit and press ENT to view the PointCodeList screen Select the PointCode you wish to edit and Press ENT to display PC screen then edit the PointCode...

Страница 46: ...ssage of Not enough data to Calculate 2 angles and 1 distance 3 angles are required appears First input the height of the instrument IH 6 1 Stationing by more than 3 known points 4 known points statio...

Страница 47: ...ENT or F5 ACCEPT to view the MEASURE screen Press ENT to view the ADD CALC SELECTION MENU screen Measuring is not needed Just press ENT Press the F1 ADD to view the KNOWN POINT COORD SETUP screen Aim...

Страница 48: ...ALC SELECTION MENU Press the F5 CALC to view the RESULT COORD OF STATIONING screen The Station Coordinates are displayed Result coordinates of free stationing can be saved for Station setup after pres...

Страница 49: ...e Point 1 Press ENT to open the PN X Y Z PH and PC input window and input each value Then press ENT to view the MEASURE screen Press ENT to view the ADD CALC SELECTION MENU screen Press F1 ADD to view...

Страница 50: ...e RESULT COORD OF STATIONING The Station Coordinates are displayed Result coordinates of free stationing can be saved for Station setup after pressing F5 ACCEPT Horizontal angle of the result coordina...

Страница 51: ...is extremely large See P4 and P6 on above Fig 1 3 The distance from a new point to a known point is extremely short or extremely long 4 A new point station point and three or more known points are ar...

Страница 52: ...take Out Press F1 STAK to view the STAKEOUT METHOD SELECTION screen Select 1 STAKE OUT and press ENT to view the STATION POINT SETUP screen Open the PN X Y Z IH and PC input window and input each Save...

Страница 53: ...tation For more details refer to 4 3 Multiple Orientation Press ENT to enter STAKEOUT COORD SETUP screen Open the PN X Y Z PH and PC input window and input each Save the data by pressing F1 SAVE Press...

Страница 54: ...ormation at once To display information with larger select ALL IN ONE INFO character select LARGE CHARACTER Press F3 DISP to view another screen Press F3 SCROLL to view another screen Press F1 NEXT to...

Страница 55: ...54 Press F5 PAGE to view another screen Press F5 PAGE to view another screen Press F2 DEV key dx dy dz change to deviation in meter Press F2 DEV key again return to dx dy dz...

Страница 56: ...from point P to Point O F Forward B Back Forward Backwards L Left R Right Left Right U UP D Down Up Down For more details on the operating procedure refer to 5 VIEW AND EDIT Press ENT or ESC to retur...

Страница 57: ...tion Press the F5 PAGE to view the other MEASURE menu 7 2 Point to Line You have to select the point A and B The distance between the two points A and B has to be at least 1m The two points A and B de...

Страница 58: ...ksight Coordinates by pressing F5 BSP Press ENT to enter Multiple Orientation For more details refer to 4 3 Multiple Orientation Following Multiple Orientation it takes you to POINT A COORD SETUP scre...

Страница 59: ...or negative If A Int P and A B is are in the same direction Int P A is positive In case of the below drawing since A B and A Int P are in the same direction Int P A is positive Int P B Distance betwe...

Страница 60: ...ut the divided distance The divided point s coordinate can be calculated and displayed Press the ACCEPT key the data will be saved and return to the measure screen Coordinates will be calculated from...

Страница 61: ...d point s coordinate can be calculated and displayed Press the ACCEPT key the data will be saved and return to the measure screen Coordinates are calculated to be divided by the number you put from A...

Страница 62: ...radius is 0 the figures of the distance between SOP and ARC is shown as a positive figure When point P is outside the circle the figures of the distance between SOP and ARC is shown as a positive fig...

Страница 63: ...P screen Open the PN X Y Z IH and PC input window and input each Save the data by pressing F1 SAVE Press ENT to view STATION POINT H ANGLE SETUP screen Input the H angle by pressing F2 INPUT F3 0SET a...

Страница 64: ...procedure of inputting the points is the same as that of STATION POINT SETUP After you are finished with the input press F1 SAVE or F5 ACCEPT to display the measurement screen Sight the target Press F...

Страница 65: ...le C Press ACCEPT to return to SOP ARC screen 7 3 2 Circle radius Input center coordinate of the circle and radius to make a circle then obtain the distance from the Stake Out Point to the circumferen...

Страница 66: ...le Orientation After you finish sighting the reference point press ENT to go to next screen Input coordinates of the center point and radius to make a circle After you are finished with input press EN...

Страница 67: ...Coordinates P1 Point 1 P2 Point 2 P3 Point 3 CP Center Point S1 Start point 1 E1 End point 1 S2 Start point 2 E2 End point 2 C1 Center point 1 C2 Center point 2 OP Observation Point The values record...

Страница 68: ...n the points and Direction of the line defined by the two points From the PowerTopoLite screen press F2 CALC to view CALCULATION screen Select 1 COGO and press ENT to view the COGO screen Select the 1...

Страница 69: ...SP input screen Input your desired Point Name by pressing keys and press ENT to open the X coordinate input screen Input your desired value by pressing each keys and press ENT to go Y coordinate Press...

Страница 70: ...er PC input EP screen is viewed Input the PN X Y Z Coordinates and PC name of the End point Press ENT to view the RESULT OF INVERSE screen C Another End point Coordinates input Input the PN X Y Z Coor...

Страница 71: ...orizontal angle of the Second point Output Coordinates of the Second point From the PowerTopoLite screen press F2 CALC to view the CALCULATION screen Select 1 COGO and press ENT to view the COGO scree...

Страница 72: ...nate input screen Input your desired value by pressing keys and press ENT to go Y coordinate Press ENT to open the Y coordinate input screen In the same manner input your desired value by pressing key...

Страница 73: ...he Second point Coordinates are displayed by plus or minus from the known Coordinates Press ENT to view the following screen The PN X Y Z and PC are viewed and can be edited If all items are OK press...

Страница 74: ...llowing screen The PN X Y Z and PC are viewed and can be edited If all items are OK press F5 ACCEPT to save them 8 1 2 3 H angle input In the same manner only the value of H angle is input as follows...

Страница 75: ...dius The Center point and radius of the circle drawn by three points are calculated by this function You can store calculated Center point Input 3 points Output Center point of the arc Radius of the a...

Страница 76: ...press F5 ACCEPT Then you go to P2 input screen Input P2 data like input of P1 If you finish the input of P2 press F5 ACCEPT Then you go to P3 input screen If you finish the input of P3 press F5 ACCEPT...

Страница 77: ...store two possible intersection points Input Line Start point and End Point Arc Center point and Radius Output Two possible intersection points From the PowerTopoLite screen press F2 CALC to view the...

Страница 78: ...put of EP press F5 ACCEPT Then you go to CP input screen If you finish the input of CP value press F5 ACCEPT Then you go to RADIUS input screen If you finish the input of RADIUS press ENT Then you go...

Страница 79: ...d End Point Second line Start point and End Point Output Intersection point between the two lines From the PowerTopoLite screen press the F2 CALC to view the CALCULATION screen Press 1 COGO to view th...

Страница 80: ...you finish an input of E1 press F5 ACCEPT Then you go to S2 input screen If you finish the input of S2 value press F5 ACCEPT Then you go to E2 input screen If you finish the input of E2 press ENT The...

Страница 81: ...c 1 Center point and Radius Arc 2 Center point and Rradius Output Two possible intersection points From the PowerTopoLite screen press F2 CALC to view the CALCULATION screen Select 1 COGO and press EN...

Страница 82: ...f R1 press F5 ACCEPT Then you go to C2 input screen C2 Center 2 point is Center point of Arc 2 Input PN Point Name X Y Z and PC Point Code of C2 point or import from the memory of rectangular coordina...

Страница 83: ...Also New Point on the line is calculated by point of start end and offset You can store the New Point Input line Start Point SP and End Point EP Offset Point OP Output New Point Offset of New Point f...

Страница 84: ...ectangular coordinate as SP by F2 LIST If you finish the input of SP value press F5 ACCEPT Then you go to EP input screen Input EP data like input of SP If you finish the input of EP press F5 ACCEPT T...

Страница 85: ...distance from Start point and Offset from line Input line Start point and End Point Distance from Start point DI Offset from the line OD moving in the direction from start point to End Point right is...

Страница 86: ...ess F5 ACCEPT Then you go to EP input screen Input EP data like input of SP If you finish the input of EP press F5 ACCEPT Then you go to DISTANCE input screen Input DI Distance from SP to point on the...

Страница 87: ...ius R Distance along arc from Start point DI Offset from the arc OD moving in the direction from Start point to End Point right is positive left is negative NOTE From Start point to End Point must be...

Страница 88: ...Z and PC Point Code of SP point or import from the memory of rectangular coordinate as SP by F2 LIST If you finish the input of SP value press F5 ACCEPT Then you go to EP input screen Input EP data li...

Страница 89: ...Offset distance from the arc to offset point If you finish the input of OFFSET press ENT Then you go to RESULT OF ARC DISTANCE OFFSET screen You can see the coordinates of offset point from the arc Pr...

Страница 90: ...points is important If you select points by ALL or FROM TO the polygon is defined according to the order of the memory address If you select points one by one by ENT the polygon is defined according t...

Страница 91: ...cancel the selection of the point press ENT again You can cancel the selected points one by one after pressing ALL F2 ALL key Press F2 ALL to select all stored points of current JOB The order of point...

Страница 92: ...91...

Страница 93: ...ection of a polygon press F1 ACCEPT to calculate The result of calculation is displayed as follows Press ENT or ESC to return to POINT SELECTION FROM THE LIST screen You change a selection and you can...

Страница 94: ...ill always be convex A polygon is generated so that an area may become the biggest It is like a rope which is laid around the points and then tightens You have to give the reference height which is us...

Страница 95: ...ut reference height is between a solid In 3D Volume the case that input reference height is higher than a solid Reference Height Total Volume Positive Volume Cut Negative Volume Fill Negative Volume F...

Страница 96: ...hich compose the polygon in order at this screen If you finish point selection of a polygon press F1 ACCEPT to go to RH screen RH stands for the Reference Height Input Reference Height If you finish i...

Страница 97: ...e target object can be measured This makes it easy to determine the heights of electric power lines bridge suspension cables and other large items used in construction From the PowerTopoLite screen pr...

Страница 98: ...re the Point Coordinates of this virtual plane by aiming at your desired points Press the F3 VPM of the PowerTopoLite screen to view the STATION POINT SETUP screen of the VPM function LIST key All sto...

Страница 99: ...sing F2 INPUT Input any horizontal angle Pressing F5 BSP The information for Back Sight Point is obtained Press ENT to finalize the input Aim at the reference point then press ENT to enter Multiple Or...

Страница 100: ...ress F1 MEAS Measured Coordinates are displayed Press ENT to view the COORD ON THE VIRTUAL PLANE screen Aim at your desired point and press ENT The Coordinates which you aim at are displayed Pressing...

Страница 101: ...ured Any Target point can be changed to the new Reference point Press the F4 RDM of the PowerTopoLite screen to view the REF POINT screen of the RDM function 10 1 PH input Press F3 EDIT to input the P...

Страница 102: ...NT screen 10 3 Target Target distance Aim at the Target 2 and press F1 MEAS to measure a distance The distance between Reference point and Target point 2 is displayed Press F5 DISP to display the Targ...

Страница 103: ...ted each corner point s coordinates are calculated One point of the traverse data uses the memory size of two or three coordinates data Therefore please check the remaining memory The calculation type...

Страница 104: ...he traverse calculation before you store other data Don t turn the power supply off until the measurement at one start point or at one corner point is completed Don t leave the MEASURE screen You can...

Страница 105: ...t be measured at the same time Please start the new traverse route after another traverse route is finished Press ENT to view the STATION POINT SETUP screen The mark is used to scroll up down Point n...

Страница 106: ...point s direction angle from the start point NOTE The direction angle set at this screen is used in the traverse calculation which will be executed later And the rotation of the H angle depends on the...

Страница 107: ...e Press ENT to view each input window by pressing the up or down arrow key and input your desired Point Name or Prism Height or Point Code Press F5 ACCEPT if the current PN PH and PC are acceptable Pr...

Страница 108: ...ss the F4 EDIT to edit the PN Point Name PH Prism Height and PC Point Code Press ENT to view each input window by pressing the up or down arrow key and input your desired Point Name or Prism Height or...

Страница 109: ...ED CALC or 4 CLOSED CALC or 5 OPEN CALC to calculate the traverse route Press ENT to view the START POINT COORD SETUP screen Start point coordinates setup Input the PN Coordinates and PC of the Start...

Страница 110: ...displayed Points being displayed Contents of e S Traverse point of Station Point The point where the instrument is set Length between last station P current P Length between start P current P Travers...

Страница 111: ...Total length is the horizontal distance error at point 1 between measured value and theoretical value Total length is the distance measured in the order of 1 2 3 4 1 For point 3 Length between last st...

Страница 112: ...ent as data of m unit Then it is converted according to the distance unit which is set in the instrument and displayed on the screen Data format 1 DC 1 In case of Text File read write Record No Site n...

Страница 113: ...ented by a 6 digit integer part and a 3 digit fraction part P Code The P Code is handled as text data if it is input L F code use CR LF 3 ExtCSV 31 Fixed NOTE This format is used when sending PointCod...

Страница 114: ...lar Data select 1 and in case of Polar Data select 2 then press ENT Press F5 SELECT to select format and data save place then press ENT FORMAT SELECTION Rectangular Data DC1 Extension DC1 CSV Extensio...

Страница 115: ...played Try again after increasing free memory space 12 1 2 Reading from Text File This command allows you to transfer the text file containing measurement point data in the internal memory of the inst...

Страница 116: ...mber of Job Files stored in the internal memory is exceeded The maximum number of Job Files stored in the file is 50 If you try to read a new file while 50 job files already exist an error message lim...

Страница 117: ...entax Total Stations please contact us to confirm it works properly It has also been confirmed that the models mentioned in the following table can be used with the R 400V series Total Station Other b...

Страница 118: ...te axis definition They are used for matching coordinate system between definition in the instrument and definition in the external device when they are different However it is necessary to match the...

Страница 119: ...IGHT is selected when data is transferred between the TS and PC cf 13 2 Coordinate axis definition They are used for matching coordinate system between definition in the instrument and definition in t...

Страница 120: ...ection 3 After the USB cable is removed close the SD USB slot cover completely CAUTION Be sure to open close the SD USB slot cover and insert remove the USB cable indoors Press F3 USB of the TRANSFER...

Страница 121: ...ve Hardware icon shown in the bottom right of the Desktop If you don t click this icon it may cause a loss of data In case the file that should be downloaded is not included try this procedure again B...

Страница 122: ...NFIRMATION screen Same procedure is performed for CSV format NOTE When Rect data DC1 is selected and data is transmitted to PC the DC1 format PointCode data cannot be transferred If CSV or ExtCSV is s...

Страница 123: ...ECT DATA Select the 1 RECEIVE RECT DATA and press ENT to view the following screen Press ENT to open the selection window Select each setting and press ENT Press ACCEPT when all selections are made DI...

Страница 124: ...XIS BASIS DIRECT 10 DISP 2 AXIS RIGHT ANGLE 11 DISP 3 AXIS HEIGHT 12 ROTATION CW 12 3 3 2 Sending data setting Select the 4 COMMUNICATION SETUP and press ENT to view the COMM SETTING SELECTION 2 SEND...

Страница 125: ...9600 2 DATA LENGTH 8 3 PARITY BITS NIL 4 STOP BITS 1 5 SIGNAL CONTROL ON 6 XON XOFF ON 7 PROTOCOL ON 8 RECORD DELIMETER CR 9 DISP 1 AXIS BASIS DIRECT 10 DISP 2 AXIS RIGHT ANGLE 11 DISP 3 AXIS HEIGHT...

Страница 126: ...ansfer with DL 01 b 1 Type of data which can be transferred With PTL POLAR DATA can be transferred by DC1 or AUX format In addition it is possible for DL 01 to receive convert POLAR DATA with DC1 DC 1...

Страница 127: ...BAUD RATE 1200 9600 2 DATA LENGTH 8 3 PARITY BITS NIL 4 STOP BITS 1 5 SIGNAL CONTROL OFF 6 XON XOFF OFF 7 ROTATION As you like PC DL 01 R 400V to RECEIVE RECT DATA 1 BAUD RATE 1200 2 DATA LENGTH 8 3...

Страница 128: ...its 8 Parity None Stop bits 1 PC DL 01 R 400V Bits per second 1200 Databits 8 Parity None Stop bits 1 c Note for the Memory capacity Data transfer failure from DL 01 to R 400V may cause reduction of m...

Страница 129: ...d on DL 01 then CSV files from PCS R 100 is selected for the type of file CSV Import Option will be appear In case the CSV data doesn t have CODE field please select PN XY or PN XYZ from following fou...

Страница 130: ...E Compare method can be selected ALL IN ONE VIEW Aiming on off can be selected OFF EDM electronic distance meter settings can be selected PRIM MEAS KEY SEC MEAS KEY EDM MIN DISP QUICK SHOT COUNT SHOT...

Страница 131: ...ect and press F5 ACCEPT to enter 13 2 Coordinate axis definition Select 2 COORD AXIS by pressing the down arrow key and press ENT to view the coordinate system definition window Press ENT to select an...

Страница 132: ...ection of the 1st Axis 1 BASIS DIRECTION 2 RIGHT ANGLE 3 HEIGHT 1 BASIS DIRECTIO N 2 RIGHT ANGLE 1 BASIS DIRECTIO N 1 BASIS DIRECTION 5 DISP 2 AXIS Define the direction of the 2nd Axis 1 RIGHT ANGLE 2...

Страница 133: ...of the coordinates Please note that the up arrow on the screen of the graphical view always shows BASIS DIRECTION In addition position of points doesn t change on the GRAPHICAL VIEW but value of coord...

Страница 134: ...ECT each time 3 Divided template 4 MATRIX How to input A by Matrix First press F1 R1 to view next screen Press F1 1Aa to view next screen Press F2 A to select A 13 4 Action method selection Select 4 A...

Страница 135: ...method takes over the functionality of our past product When this option is selected the menu screen will be shown after inputting necessary items 13 5 Remote method selection Select 5 REMOTE METHOD a...

Страница 136: ...mote measurement is performed on the Rotated plane which is always perpendicular to the present line of sight and induces the reference point as shown left 13 6 Compare method selection Select 6 COMPA...

Страница 137: ...UEST AIMING and press ENT to view the REQUEST AIMING selection window Press ENT to select and press F5 ACCEPT After pressing ENT on STATION POINT H ANGLE SETUP screen you can choose whether or not the...

Страница 138: ...ion factor Elevation Factor as used here refers to Average Elevation Correction and Scale Factor carried out as part of the measurement process among the special functions It is effective only with ME...

Страница 139: ...ge Elevation Average H Averaged on site elevation Input range 9999 9998 9999 9998m 2 Scale Factor Scaling On site scaling coefficient Input range 0 00000001 1 99999998 13 10 Duplicate point check When...

Страница 140: ...ATION POINT H ANGLE SETUP screen appears next to ANG DIST screen When RECT DATA is selected MEASURE screen is displayed 13 12 Both faces meas When ON is selected and sighting the BSP Back Sight Point...

Страница 141: ...ave Mode If you switch to SAVE MODE you can change the display when Polar data is displayed When HA HD VD are selected at VIEW EDIT of POLAR DATA of EDIT the display will be changed as shown in the ri...

Страница 142: ...ll rights reserved The duplication reuse or sale of any information provided on this manual including but not limited to images is strictly prohibited without expressed permission from the copyright o...