24
8. [ADJ] AF Joint stroke
[Required equipment]
Vernier calipers
①
Set the AF lever (0-A115) to the AF.C position.
②
AF coupler(0-S300) must be projected from
the mount surface by 1.2mm or more.
③
When the mount lock pin comes to the mount surface
with depressing the mount lock lever, the AF coupler
must not be projected out of the mount surface.
④
Adjust 0-A121 by turning an eccentric screw,
and apply the screw lock.
9. L2 and 0-L3
[Caution]
Confirm there is neither dust nor scratch on L2 and 0-L3.
①
M3
②
0-L3
③
Tighten M16 (Adjustment screw) temporary
while pushing 0-L3 front side.
④
Down the focusing screen frame (0-M4) by releasing the hook portion.
⑤
Push the arrow part in figure and install M22.
In the case of temporary adjustment, Using with the M22-00E(0.35).
⑥
Put the focusing screen (L2) on the frame and then push it back until it locks in place.
10. M301
①
Eyepiece (M301,L7 and other)
②
TY-CNL-D1.7x4.0
(
x2
)
④
⑤
⑥
①
②
SL
①
②
③
④
①
②
③