77420 - 67/107 -
5-2. AF FI adjustment
[Required equipments]
□
AF chart for 2m (No.1 and 2)
□
AF master lens for 2m
*Set the AF chart for 2m as following condition.
1) Distance between AF chart and camera mount surface: 1,954.5mm(=1.9545m).
2) Chart should be set at perpendicularly against light axis of the lens.
3) Lighting the chart approx LV11~12 on surface of chart.
If brightness is not enough, adjustment will not be passed (NG)
◆
Example for lighting
→
AF Chart No.2
①
Double click [K-5_FI Ver100.exe] in [K-5_FI Ver100] folder to start up software.
(Following adjusting screen is displayed)
②
Input temperature(
℃
) and press [Enter] key. ((a):Select Celsius or Fahrenheit by cursor)
*In case of NG, there is possibility that the temperature is difference more than 2
℃
between room
temperature and temperature for inside of camera.
*Adjust the camera after the camera fit in the room temperature.
③
When temperature adjustment is completed,
right screen is displayed.
→
④
Set the camera to AF chartNo.1 (vertical line).
⑤
Press [OK] button then start to align the cart position.
⑥
If the chart and center of camera are out of alignment, below screen will be displayed.
Align the center by moving camera position. (Match a yellow line with red line.)
@
②