77420 - 46/107 -
19. A301 (Top cover)
* Confirm that the top cover parts are completely installed and ready for installation.
①
If main switch land is soldered, unsoldered, unsolder main switch land.
②
Apply G151 on main switch contact.
③
Confirm that there is no dust or no damage on contact. The contact must be the same height.
④
Solder 6 lead wires from A301.
⑤
Connect flex (Flip lock) the fix DT (5x5)
⑥
Pop-up the flash by releasing the lever as shown in figure.
(
following page
)
③
⑥
①
Main SW
land
G151
②
④
Black
Blue
Green, Brown
Yellow, White
⑤