XLHP™ High Performance Heat Pump Installation and User’s Guide
16
XLHP™ High Performance Heat Pump Installation and User’s Guide
Service Menu Tree Guide
(Press UP and DOWN Arrows Simultaneously)
SERVICE
MENU TREE
LANGUAGE - IDIOMA - LANGUE
ENGLISH / ESPANOL / FRANCAIS
SOFTWARE VERSION
REV. ____
PUMP START TIME
TIME = 1 - 4 HRS
TEMPERATURE SCALE
FAHRENHEIT / CELSIUS
PRESS TANK1/TANK2
TO EXIT SETUP
WP HP LP T1 T2
1 1 1 0 0
FAN COMP PMP REV
1 1 1 0
DEFROST
ENABLE / DISABLE
WATER TEMP OFFSET
OFFSET = -2 TO +2
PUMP START DELAY
TIME = 0 - 5 MINS
EXTEND
ENABLE / DISABLE
AUTOSET
ENABLE / DISABLE
†
††
RUN TIMES/COUNTS
OR TO VIEW
TEMP. RECORD
HOUR # ___ ___°F
Navigating the Service Menu Screens
Press the UP and DOWN arrows simultaneously. If no
activity is detected after 15 seconds, the display will
return to the main screen.
1. Language Selection
Displays the language selected. Select either English,
Spanish or French using the UP and DOWN arrows.
2. Software Revision
Displays the software revision level loaded on the
control board.
3. Pump Start Time
Displays the period at which the heat pump will
close the AutoSet contactor to start the filter pump.
Adjustable from 1 to 4 hours using the UP and
DOWN arrows.
4. Pump Start Delay
Displays the time period between heat pump start
cycles. Adjustable from 0 to 5 minutes using the UP
and DOWN arrows
5. Temperature Scale
Determines if the water temperature actual reading
and set point is displayed in degrees Fahrenheit or
Celsius. Adjusted between Fahrenheit and Celsius
using the UP and DOWN arrows.
6. Temp Offset
Adjusts the measured water temperature up or
down to allow the operator to match the heat pump
displayed temperature to a remote temperature
monitoring device. The offset can be varied from -2
to +2 using the UP and DOWN arrows.
7. Defrost Screen
Allows the user to Enable/Disable defrost cycle.
8. AutoSet Screen
Allows the user to Enable/Disable AutoSet feature.
9. Extend Screen
Allows the user to Enable/Disable Extend feature.
10. Input Screen and Output Screen
The Input and Output screens are diagnostic displays
which show the status of the input sensors and output
devices. The number one (1) is displayed when the
associated input/output is on and zero (0) is displayed
when the associated input/output is off.
11. Temperature Log / Run Time Counters
These screens display a list of compressor, fan and
valve run times, and a history of measured water
temperatures. This information is provided so the
user can easily track performance and troubleshoot.
12. Exit Set Up
Pressing the TANK1/TANK2 button while this screen
is displayed returns the display to the Tank 1 or Tank
2 Run Screen as appropriate.
††
†
INPUT STATUS
WP = WATER PUMP SWITCH
HP = HIGH REFRIGERANT PRESSURE SWITCH
LP - LOW REFRIGERANT PRESSURE SWITCH
T1- TANK1 REMOTE
T2 - TANK2 REMOTE
†
OUTPUT STATUS
FAN - FAN
COMP - COMPRESSOR
PMP - FILTER PUMP
REV - REVERSING VALVE
††
The number one (1) is
displayed when the
associated input/output is
ON and zero (0) is displayed
when input/output is OFF.