background image

9

SYSTEM INSPECTION

General:

Wash the outside of the filter with a mild detergent and water. Rinse off with
a hose.

NOTICE: DO NOT use solvents to clean the filter; solvents may damage
plastic components in the system.

NOTICE: Open the air bleed valve and bleed all air from the filter each time
the pump is stopped and restarted.

Weekly Inspection:

1. Remove debris from the pool skimmer basket.

2. Stop the pump; open the air release valve to release all pressure.

3. Remove the trap cover and basket; remove debris.

4. Check the pump for leaks. If found, see the pump owner's manual.

5. Replace the trap basket and the cover. Tighten the cover securely hand

tight. DO NOT use a lid wrench to tighten it.

6. Start the pump. When the filter air release valve runs a solid stream of

water, close the valve.

7. When the system has returned to normal operation, check the filter

pressure. If the filter pressure is 10 PSI (69kPa) or more higher than the
initial startup pressure, the filter needs cleaning. See “Module Cleaning
Procedure”, Pages 7 and 8.

WINTERIZING

Explosion hazard. Purging the system with compressed air can

cause components to explode, with risk of severe injury or death to anyone
nearby. Use only a low pressure (below 5 PSI), high volume blower when air
purging the pump, filter, or piping.

NOTICE: Protect the filter from freezing. Allowing the filter to freeze will
damage it and will void the warranty.

1. Clean the filter according to instructions (Pages 7 and 8) before

winterizing.

2. Stop the pump.

3. Open the air release valve; open all the system valves.

4. Remove the drain plugs from the trap, pump, and filter.

5. Drain the system piping.

A. Gravity drain system as far as possible.

B. Protect areas which retain water with non-toxic propylene glycol

antifreeze (“RV antifreeze”).

6. Loosen the union nuts (if used) to drain all water from the filter interior.

Leave these nuts loose until the system is restarted.

7. Disassemble the filter (follow instructions under “Filter Disassembly”,

Pages 6 and 7). Remove the filter module and store it in a warm, dry
area.

8. If the filter is equipped with an optional internal spring check valve (in the

tank outlet), manually open the check valve to allow any water trapped in
the tank to drain.

9. Cover the filter with plastic or tarpaulin to prevent water entrance and

freezing.

NOTICE

The filter outlet piping will not empty
through the filter drain. Make sure that
the outlet piping has a separate drain for
winterizing.

Содержание STA-RITE PLM100

Страница 1: ...27330 919 566 8000 10951 West Los Angeles Ave Moorpark CA 93021 805 553 5000 Trademarks and Disclaimers System 2 Posi Lok Sta Rite and Pentair Water Pool and Spa are trademarks and or registered trademarks of Pentair Water Pool and Spa Inc and or its affiliated companies in the United States and or other counties Unless noted names and brands of others that may be used in this document are not use...

Страница 2: ...xternal source of pressurized water 2 Use equipment only in a pool or spa installation 3 Trapped air in system can cause explosion BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids lock rings and system accessories before testing Release all air in system before testing Tighten Sta Rite pump t...

Страница 3: ... gauge immediately Cleaning interval is based on pressure rise not on length of time filter is operated Different water conditions will have different normal cleaning intervals Check local codes for restrictions on waste water disposal requirements NOTICE Some pool disinfectants may clog filter module To maximize module life and filter cycle time closely follow disinfectant manufacturer s instruct...

Страница 4: ...14 175 16 3 200 18 6 300 27 9 Max Rated Flow GPM LPM Commercial 37 140 47 178 56 212 66 249 75 284 113 428 Max Operating Pressure PSI kPa 50 345 50 345 50 345 50 345 50 345 50 345 Max Continuous Water Temperature F C 104 40 104 40 104 40 104 40 104 40 104 40 Dimension A Height mm 27 3 4 705 27 3 4 705 27 3 4 705 27 3 4 705 27 3 4 705 37 5 8 956 Dimension B Minimum Service Height mm 38 1 2 978 38 1...

Страница 5: ... the other two 2 NPT ports which are not marked These two ports inlet and drain are interchangeable to allow for the most convenient piping run After you have piped the inlet and drain apply the inlet decal to the port to which you have run the inlet piping For ease of maintenance use Sta Rite union couplings to connect the piping to the filter inlet and outlet ports Keep piping tight and free of ...

Страница 6: ... until it locks behind the safety latch see Figure 3 E If the ring was already locked remove it and the upper tank shell Inspect and clean the O ring and all sealing surfaces Relubricate the O ring NOTICE Lubricate O ring only with the silicone grease provided or equivalent as other lubricants may cause the ring to swell DO NOT lubricate Posi Lok ring or threads on lower tank shell as this may col...

Страница 7: ...n the bottom of the filter cartridge over the tank outlet port Push down firmly to seal 3 Ensure that the air bleed assembly on top of the module is clean and properly mounted NOTICE Lubricate O ring only with the silicone grease provided or equivalent as other lubricants may cause the ring to swell DO NOT lubricate Posi Lok ring or threads on lower tank shell as this may collect grit and make rem...

Страница 8: ...p of module 5 Follow all steps in the Assembly and Initial Startup sections of this manual Special Cleaning Instructions Use this procedure to clean scale or oils which are not removed by hosing down module Be sure to dispose of spent chemicals according to all applicable codes and waste disposal ordinances Use a soft stream nozzle to minimize flying water and spray Risk of fire or explosion Isola...

Страница 9: ...to explode with risk of severe injury or death to anyone nearby Use only a low pressure below 5 PSI high volume blower when air purging the pump filter or piping NOTICE Protect the filter from freezing Allowing the filter to freeze will damage it and will void the warranty 1 Clean the filter according to instructions Pages 7 and 8 before winterizing 2 Stop the pump 3 Open the air release valve ope...

Страница 10: ...d 8 B Water is chemically out of balance consult pool professional C Excessive air in filter Vent air from tank and check for pump suction pipe leaks Clean air bleed filter in module assembly with a hose and soft flow nozzle D Filter is too small Install an additional filter E Pool water contains iron See Special Cleaning Instructions Page 8 F Heavy or improper application of powdered chlorine tab...

Страница 11: ...d assembly 1 24800 0121 12 Filter module PLM100 1 27002 0100S 12 Filter module PLM125 1 27002 0125S 12 Filter module PLM150 1 27002 0150S 12 Filter module PLM175 1 27002 0175S 12 Filter module PLM200 1 27002 0200S 12 Filter module PLM300 1 27002 0300S 13 Spring check valve 1 27001 0130S Accessory package 1 27001 0140 Decal logo 1 27001 0041 Decal warning 1 27001 0042 Decal operating instr 1 27002 ...

Страница 12: ...Blank Page ...

Отзывы: