background image

The EnviroMAX 800

 should only be serviced by certified Pentair service agents. 

For best results and to ensure warranty is not void, insist on use of only genuine Pentair 

service parts.

To avoid dangerous or fatal electrical shock hazard, turn OFF power to pump and remove

plug from power outlet before working on pump.

The power supply cord has a type 'Y' attachment and if service is required to the power

cord, it must be replaced with the specialised power cord assembly by Pentair Water

service agent or similarly qualified personnel in order to avoid a hazard. Warranty is void 

if unauthorised modifications are made to any component.

Troubleshooting guide

SYMPTOM

CAUSE

REMEDY

Low water pressure, low 

flow from pump.

Suction leaks / lost prime.

 

Pump must be primed; make 
sure that the pump casing and 
strainer are full of water. Refer 
priming instructions. 

 

Make sure there are no leaks 
in suction piping and ensure all 
o-rings are present and clean. 

 

Make sure suctions pipe inlet 
is well below the water level to 
prevent pump from sucking air. 

 

Suction lift of 3 to 6 metres will 
reduce performance. Suction 
lift of more than 6 metres will 
prevent pumping and cause pump 
to lose prime. In either instance, 
move the pump closer (vertically) 
to water source. Ensure that the 
suction pipe diameter is large 
enough.

Low speed setting.

 

Check speed setting. Refer 
to speed selection section of 
this manual. Reset to default if 
necessary.

Clogged pipe / strainer /

impeller / filter system.

 

Ensure trap is not clogged with 
debris; clean basket and/or filter. 

 

Make sure that the impeller is not 
clogged. This should be checked 
by qualified personnel only. 

 

Pump may be trying to push 
too high a column of water. If 
so, a higher pressure pump is 
required.

Troubleshooting

12

Содержание Sta-Rite EcoSelect Enviromax 800

Страница 1: ...Variable Speed Pool Pump...

Страница 2: ...available When you see the Eco Select brand on one of our products you ll know it is our greenest and most efficient product in that equipment category These products do the best job of saving energy...

Страница 3: ...nstallation Pump positioning 6 Piping 6 Pool Outlets 6 Electrical 7 Equipotential Bonding 7 Operation Priming the Pump 8 Speed Selection 9 Variable Speed Adjustment 9 Priming 10 Service Maintenance 11...

Страница 4: ...hutting down the motor in the event of a locked rotor under voltage over voltage or over current condition and will automatically reduce the speed during an over temperature condition Precision fit in...

Страница 5: ...850RPM 975W P2 800W 6 7A IP Rating IP25 Inlet Suction ABS Barrel Union to suit 50mm PVC pressure pipe to AS NZS 1477 Outlet Discharge ABS Barrel Union to suit 50mm PVC pressure pipe to AS NZS 1477 Max...

Страница 6: ...0 14 0 12 0 10 0 8 0 6 0 4 0 2 0 0 0 0 0 100 0 200 0 300 0 400 0 500 0 Head m Flow L min 2850RPM 2600RPM 2400RPM 2200RPM 2000RPM 1800RPM 1600RPM 1450RPM EnviroMAX 800 Performance Chart Technical Infor...

Страница 7: ...lation 200sq cm min inlet outlet and air circulation Allow 200mm to keep rear of motor clear b Have adequate floor drainage to prevent flooding and be protected from excess moisture c Be solid level r...

Страница 8: ...electrical problem If RCD trips and will not reset have a qualified electrician inspect and repair electrical system c Incorrect voltage can cause fire or seriously damage pump and voids warranty d Vo...

Страница 9: ...bricate the oring The original equipment O ring contains a permanent internal lubricant a Before removing trap lid SWITCH OFF POWER SUPPLY to pump b CLOSE SHUT OFF VALVES on suction and discharge pipe...

Страница 10: ...er ON OFF state Press and hold button corresponding to speed you wish to change Hold for 3 seconds and a light should begin to flash To decrease speed by 50rpm increments with 1000rpm as the minimum l...

Страница 11: ...and ready to adjust time Limit time to 240min maximum and minimum for 1Min Pressing the button low will lower the time by 1 min step Holding for 2 seconds to decrease time continuously Pressing the b...

Страница 12: ...re there are no leaves or debris which could become a fire hazard or choke the motor fan Check that there are no leaks from under the pump If there are this could be a sign of a leaking mechanical sea...

Страница 13: ...ure that the pump casing and strainer are full of water Refer priming instructions Make sure there are no leaks in suction piping and ensure all o rings are present and clean Make sure suctions pipe i...

Страница 14: ...essary Pump running too slow Low speed setting Check speed setting Refer to speed selection section of this manual Reset to default if necessary Motor high temperature limit exceeded Ensure motor fins...

Страница 15: ...ir service agent Motor Flash Codes No of flashes Microcontroller failure Mains under voltage Over Temperature Over Current Mains over voltage Output shaft seized Self check failed Motor fault Microcon...

Страница 16: ...Spare Parts 14 16 13 8 3 6 2 5 4 10 1 15 9 7 12 11 a 9a 9c 9b 9d 15...

Страница 17: ...NERS KIT 801280 9 PUMP CASING ASSEMBLY C176 71P 9a LID 17307 0111 9b O RING LID 35505 1440 9c BASKET C8 58P 9d DRAIN PLUG O RING U178 920P 10 O RING PUMP CASE U9 373 11 SCREW 8 32 x 22mm SS PHILLIPS H...

Страница 18: ...NOTES Notes 17...

Страница 19: ...NOTES Notes 18...

Страница 20: ...664 266 Email au sales pentair com Web www pentairpool com au Information contained here in remains the property of Pentair Australia Pty Ltd Any reproduction display publication modification or distr...

Отзывы: