Typical Pressure Booster System 

7

INSTALLATION

Hazardous pressure. Install a relief valve as 

shown capable of passing entire pump flow at 75 PSI. 

Pump body may explode if internal pressure exceeds 75 

PSI.

Never run pump against closed discharge. 

To do so can boil water inside pump, causing hazard-

ous pressure in unit, risk of explosion and possibly 

scalding persons handling pump.
NOTICE:
 The incoming flow rate must equal or exceed 

the minimum pump flow requirement of 6 Gallons per 

Minute or the pump will fail. As a rule, the pump will 

not increase the flow rate in the system.
A low pressure safety cutoff switch is recommended to 

shut off power to the pump in case of low discharge 

pressure caused by plugged nozzle, interruption to the 

incoming water supply, etc.

For pressure switch adjustment instructions, refer to the 

label inside the cover of the pressure switch.

The system can be located indoors or outdoors. Make 

sure that the site is level, solid, well drained, and pro-

tected from the weather and from freezing.
1.  Turn off city water to house.
2.  Install pipe as shown (Figures 6 & 7). Be sure to 

include unions and stop valves so pressure booster 

unit can be removed for service without interrupting 

household water supply. A spring loaded check valve 

ahead of the booster system and a low pressure cutoff 

switch after it are recommended (You may wish to 

replace the standard pressure switch with a pressure 

switch that includes a low pressure cutoff).

3.  Use PTFE pipe thread sealant tape on all piping joints 

to prevent leaks. 

Please go to Pages 8 and 9 for electrical hookup.

Gate Valve

and Union

for Service

Access

Union and

Gate Valve

for Service

Access

City Water

Flow In

Water Out

to Household 

Check

Valves

Relief

Valve

Pressure

Switch

Tee

Pressure

Gauge

Low Pressure

Cutoff Switch

2882 0198

Gate Valve

and Union

for Service

Access

Gate Valve

and Union

for Service

Access

Water Out to

Household

Check

Valves

Relief

Valve

Pressure

Gauge

Tee

Low

Pressure

Cutoff

Switch

2887 0198

Pressure

Switch

City Water

Flow In

  If Minimum 

Use 

Set

 Incoming System   Pressure Switch 

Tank

 

Pressure Is:  

Rated At: 

Precharge at:

 

Below 20 PSI

 

20/40; set cut-in 

18 PSI

 

 

 

to 20 PSI

 

20-30 PSI

 

30/50; set cut-in 

28 PSI

 

 

 

to 30 PSI

 

30-40 PSI

 

40/60; set cut-in 

38 PSI

 

 

 

to 40 PSI

Table I: Pressure Switch Setting for Booster System

Low Pressure Cutoff 
Switch (1)
Check Valves (2)
Gate Valves (2)
Relief Valve (1)

Pressure Gauge (1)
Unions (3)
Elbow (1)
Tees (2)
Piping

User Supplied Components:

Figure 6: 
Model SNCP42

Figure 7: Model SNCP15

Содержание SN Series

Страница 1: ...tion Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien composer le 888 782 7483 Français Pages 15 27 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba llame al 888 782 7483 Español Paginas 28 40 2400 0496 NF SN Series Série SN Serie SN HN Series Série HN Serie HN 2012 Pentair In...

Страница 2: ... capacitor terminals If in doubt consult a qualified electrician General Safety Do not touch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling Do not allow pump or any system component to freeze To do so will void warranty Pump water only with this pump Periodically inspec...

Страница 3: ...ee phase motors must be protected by three leg ambient compensated extra quick trip overload relays of the recommended size or the warranty is void Your only remedy and STA RITE s only duty is that STA RITE repair or replace defective products at STA RITE s choice You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing deal...

Страница 4: ...he suction port on the pump include a check valve if your pump is not equipped with one see Figure 1 Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so that it slopes slightly upward from the well to the pump high spots can cause air pockets which can air lock the pump Seal the suction pipe joints with PTFE pipe thread sealant tape Joints must ...

Страница 5: ...ction pipe The suction pipe should be at least as large as the suction port on the pump 2 Assemble a foot valve and suction pipe Figure 3 Make sure that the foot valve works freely Use PTFE pipe thread sealant tape on threaded pipe joints Protect the foot valve assembly from fish trash etc by installing a screen around it see Figure 3 3 Lower the pipe into the water until the strainer is five feet...

Страница 6: ...must be at least as large as the discharge port 3 Remove the 1 8 NPT pipe plug from the pump Air Volume Control AVC port see Figure 5 Run tubing from the pump s AVC port see Figure 5 to the port on the AVC mounted on the tank See instructions provided with tank and AVC for details AVC port location will vary depending on your pump model see exploded view Page 11 Congratulations You have just compl...

Страница 7: ...ster unit can be removed for service without interrupting household water supply A spring loaded check valve ahead of the booster system and a low pressure cutoff switch after it are recommended You may wish to replace the standard pressure switch with a pressure switch that includes a low pressure cutoff 3 Use PTFE pipe thread sealant tape on all piping joints to prevent leaks Please go to Pages ...

Страница 8: ...nder the motor end cover should look like the one below Dial Type Voltage Selector To change to 115 volts 1 Make sure power is off 2 Turn the dial counter clockwise until 115 shows in the dial window 3 Attach the power lead wires to the power lead terminals Make sure the wires are secure 4 Attach the ground wire to the green ground screw 5 Reinstall the Motor end cover Go to Wiring Connections bel...

Страница 9: ...ounding protection If the pressure switch is not connected to the motor connect the green ground screw in the switch to the green ground screw under the motor end cover Use a solid copper wire at least as large as the power supply wires 3 Connect the ground wire to a grounded lead in a service panel to a metal underground water pipe to a metal well casing at least ten feet 3M long or to a ground e...

Страница 10: ...everal times in order to get all the trapped air out of the piping A pump lifting water 25 may take as long as 15 minutes to prime 4 After the pump has built up pressure in the system and shut off check the pressure switch operation by opening a faucet or two and running enough water out to bleed off pressure until the pump starts The pump should start when pressure drops to 30 PSI and stop when p...

Страница 11: ...40P J105 40P J105 40P 7 Diffuser 1 L1 25P L1 25P L1 25P 8 Diffuser Gasket 1 N20 34 N20 34 N20 34 9 Quick Connect 1 4 NPT 1 U11 217P U11 217P 10 Pump Body Assembly 1 N176 43 N176 43A N176 43 11A Nozzle 1 N34P 17 43 N34P 17 43 N34P 17 43 11B Venturi 1 N32P 66 N32P 67 N32P 66 12 Pipe Plug 1 4 NPT Hex Hd 4 U78 941ZPV 3 U78 941ZPV 3 U78 941ZPV 13 Base 1 J4 9 J4 9 J4 9 14 Hex Capscrew 3 8 16 x 1 1 4 Lg ...

Страница 12: ...1 N20 34 Diffuser Screw 3 U30 489SS U30 489SS Diffuser Star Washer 3 U43 21SS U43 21SS 9 Quick Connect 1 4 NPT 1 U11 217P U11 217P U11 217P 10 Pump Body Assembly 1 N176 43B N176 44 N176 44A 11A Nozzle 1 N34P 21 47 J34P 44 54 J34P 44 54 11B Venturi 1 N32P 75 N32P 64 N32P 65 12 Pipe Plug 1 4 NPT Hex Hd 4 U78 941ZPV 3 U78 941ZPV U78 941ZPV 13 Base 1 J4 9 J4 9C J4 9C 14 Hex Capscrew 3 8 16 x 1 1 4 Lg ...

Страница 13: ... N176 43B N176 43B N176 44 N176 44 N176 44A N176 44A 11A Venturi 1 N32P 75 N32P 75 N32P 64 N32P 64 N32P 65 N32P 65 11B Nozzle 1 N34P 21 47 N34P 21 47 J34P 44 54 J34P 44 54 J34P 44 54 J34P 44 54 12 Pipe Plug 1 4 NPT Hex Hd U78 941ZPV 3 U78 941ZPV 3 U78 941ZPV 4 U78 941ZPV 4 U78 941ZPV 4 U78 941ZPV 4 13 Capscrew 3 8 16x1 1 2 Lg Hex Hd 2 U30 76ZP U30 76ZP U30 76ZP U30 76ZP 14 Base 1 J4 9 J4 9 J4 9C J...

Страница 14: ...and or strainer are Raise foot valve and or strainer above bottom of water source buried in sand or mud Clean foot valve and strainer Water level is too low for shallow well A deep well jet package may be needed over 25 ft to water setup to deliver water to deliver water Pump does not Water level in well is lower than A deep well jet will be needed if your well is more than 25 7 6M deliver water t...

Отзывы: