Troubleshooting 

14

   

SYMPTOM 

POSSIBLE CAUSE(S) 

CORRECTIvE ACTION

  Motor will not run 

Disconnect switch is off 

Be sure switch is on.

    

Fuse is blown or circuit breaker tripped 

Replace fuse or reset circuit breaker.

    

Starting switch is defective 

DISCONNECT POWER; Replace starting switch.

    

Wires at motor are loose,  

Refer to instructions on wiring (Page 8). DISCONNECT POWER; check and 

  

disconnected, or wired incorrectly  

tighten all wiring.  

    

 

  

 

Capacitor voltage may be hazardous. To discharge  

    

  

capacitor, hold insulated handle screwdriver BY THE HANDLE and  

    

  

short capacitor terminals together. Do not touch metal screwdriver  

    

  

blade or capacitor terminals. If in doubt, consult a qualified electrician.

   

Pressure switch contacts are dirty 

DISCONNECT POWER and file contacts with emery board or nail file.

  Motor runs hot and  

Motor is wired incorrectly 

Refer to instructions on wiring.

  overload kicks off 

Voltage is too low 

Check with power company. Install heavier wiring if wire size is too small   

    

  

(See Electrical / Wiring Chart).

   

Pump cycles too frequently 

See section below on too frequent cycling.

  Motor runs but no  

Pump in new installation did  

In new installation: 

  water is delivered* 

not pick up prime through:  

    

  1. Improper priming  

  1. Re-prime according to instructions. 

    

  2. Air leaks 

  2. Check all connections on suction line, AVC, and ejector with

   

 

      soapy water or shaving cream.

    

  3. Leaking foot valve or check valve 

  3. Replace foot valve or check valve.

    

Pump has lost prime through: 

In installation already in use: 

     

  1. Air leaks 

  1. Check all connections on suction line and shaft seal. 

    

  2. Water level below suction pipe inlet 

  2. Lower suction line into water and re-prime. If receding water level  

    

  

      in well exceeds 25’ (7.6M), a deep well pump is needed.

   

Foot valve or strainer is plugged 

Clean foot valve or strainer.

   

Ejector or impeller is plugged 

Clean ejector or impeller.

   

Check valve or foot valve is stuck shut  

Replace check valve or foot valve.

    

Pipes are frozen 

Thaw pipes. Bury pipes below frost line. Heat pit or pump house.

    

Foot valve and/or strainer are  

Raise foot valve and/or strainer above bottom of water source. 

    

buried in sand or mud 

Clean foot valve and strainer.

   

Water level is too low for shallow well   

A deep well jet package may be needed (over 25 ft. to water)  

   

setup to deliver water 

to deliver water.

  Pump does not  

Water level in well is lower than  

A deep well jet will be needed if your well is more than 25’ (7.6M) 

  deliver water to full  

estimated 

depth to water.

  capacity 

Steel piping (if used) is corroded or  

Replace with plastic pipe where possible, otherwise with new steel pipe. 

   

limed, causing excess friction

    

Piping is too small in size 

Use larger piping.

    

Packed well point 

Backflush well point or sink new point.

  Pump delivers water but 

Pressure switch is out of adjustment or 

DISCONNECT POWER; adjust or replace pressure switch. 

  does not shut off or 

contacts are welded together

  pump cycles too 

Faucets have been left open 

Close faucets.

  frequently 

Venturi, nozzle or impeller is clogged 

Clean venturi, nozzle or impeller.

   

Standard pressure tank is waterlogged 

Drain tank to air volume control port. Check AVC for defects. Check 

   

and has no air cushion 

all connections for air leaks.

   

Pipes leak 

Check connections.

   

Foot valves leak 

Replace foot valve.

   

Air charge too low in pre-charged tank 

DISCONNECT POWER and open faucets until all pressure is relieved.

   

 

Using tire pressure gauge, check air pressure in tank at valve stem  

   

 

located on the tank. If less than pressure switch cut-in setting (30-50  

   

 

PSI), pump air into tank from outside source until air pressure is 2 PSI  

 

   

 

less than cut-in setting of switch. Check air valve for leaks (use soapy 

   

 

solution) and replace core if necessary.

  Air spurts from faucets 

Pump is picking up prime 

When pump has picked up prime, it should pump solid water with no air.

   

Leak in suction side of pump 

Suction pipe is sucking air. Check joints for leaks with soapy water.

   

Well is gaseous 

Consult factory about installing a sleeve in the well

   

Intermittent over-pumping of well. 

Lower foot valve if possible, otherwise restrict pump discharge

    

(Water drawn down below foot valve.)

 

* (Notice: Stop 

pump; then check 

prime before look-

ing for other causes. 

Unscrew priming 

plug and see if water 

is in priming hole).

Содержание SN Series

Страница 1: ...tion Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien composer le 888 782 7483 Français Pages 15 27 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba llame al 888 782 7483 Español Paginas 28 40 2400 0496 NF SN Series Série SN Serie SN HN Series Série HN Serie HN 2012 Pentair In...

Страница 2: ... capacitor terminals If in doubt consult a qualified electrician General Safety Do not touch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling Do not allow pump or any system component to freeze To do so will void warranty Pump water only with this pump Periodically inspec...

Страница 3: ...ee phase motors must be protected by three leg ambient compensated extra quick trip overload relays of the recommended size or the warranty is void Your only remedy and STA RITE s only duty is that STA RITE repair or replace defective products at STA RITE s choice You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing deal...

Страница 4: ...he suction port on the pump include a check valve if your pump is not equipped with one see Figure 1 Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so that it slopes slightly upward from the well to the pump high spots can cause air pockets which can air lock the pump Seal the suction pipe joints with PTFE pipe thread sealant tape Joints must ...

Страница 5: ...ction pipe The suction pipe should be at least as large as the suction port on the pump 2 Assemble a foot valve and suction pipe Figure 3 Make sure that the foot valve works freely Use PTFE pipe thread sealant tape on threaded pipe joints Protect the foot valve assembly from fish trash etc by installing a screen around it see Figure 3 3 Lower the pipe into the water until the strainer is five feet...

Страница 6: ...must be at least as large as the discharge port 3 Remove the 1 8 NPT pipe plug from the pump Air Volume Control AVC port see Figure 5 Run tubing from the pump s AVC port see Figure 5 to the port on the AVC mounted on the tank See instructions provided with tank and AVC for details AVC port location will vary depending on your pump model see exploded view Page 11 Congratulations You have just compl...

Страница 7: ...ster unit can be removed for service without interrupting household water supply A spring loaded check valve ahead of the booster system and a low pressure cutoff switch after it are recommended You may wish to replace the standard pressure switch with a pressure switch that includes a low pressure cutoff 3 Use PTFE pipe thread sealant tape on all piping joints to prevent leaks Please go to Pages ...

Страница 8: ...nder the motor end cover should look like the one below Dial Type Voltage Selector To change to 115 volts 1 Make sure power is off 2 Turn the dial counter clockwise until 115 shows in the dial window 3 Attach the power lead wires to the power lead terminals Make sure the wires are secure 4 Attach the ground wire to the green ground screw 5 Reinstall the Motor end cover Go to Wiring Connections bel...

Страница 9: ...ounding protection If the pressure switch is not connected to the motor connect the green ground screw in the switch to the green ground screw under the motor end cover Use a solid copper wire at least as large as the power supply wires 3 Connect the ground wire to a grounded lead in a service panel to a metal underground water pipe to a metal well casing at least ten feet 3M long or to a ground e...

Страница 10: ...everal times in order to get all the trapped air out of the piping A pump lifting water 25 may take as long as 15 minutes to prime 4 After the pump has built up pressure in the system and shut off check the pressure switch operation by opening a faucet or two and running enough water out to bleed off pressure until the pump starts The pump should start when pressure drops to 30 PSI and stop when p...

Страница 11: ...40P J105 40P J105 40P 7 Diffuser 1 L1 25P L1 25P L1 25P 8 Diffuser Gasket 1 N20 34 N20 34 N20 34 9 Quick Connect 1 4 NPT 1 U11 217P U11 217P 10 Pump Body Assembly 1 N176 43 N176 43A N176 43 11A Nozzle 1 N34P 17 43 N34P 17 43 N34P 17 43 11B Venturi 1 N32P 66 N32P 67 N32P 66 12 Pipe Plug 1 4 NPT Hex Hd 4 U78 941ZPV 3 U78 941ZPV 3 U78 941ZPV 13 Base 1 J4 9 J4 9 J4 9 14 Hex Capscrew 3 8 16 x 1 1 4 Lg ...

Страница 12: ...1 N20 34 Diffuser Screw 3 U30 489SS U30 489SS Diffuser Star Washer 3 U43 21SS U43 21SS 9 Quick Connect 1 4 NPT 1 U11 217P U11 217P U11 217P 10 Pump Body Assembly 1 N176 43B N176 44 N176 44A 11A Nozzle 1 N34P 21 47 J34P 44 54 J34P 44 54 11B Venturi 1 N32P 75 N32P 64 N32P 65 12 Pipe Plug 1 4 NPT Hex Hd 4 U78 941ZPV 3 U78 941ZPV U78 941ZPV 13 Base 1 J4 9 J4 9C J4 9C 14 Hex Capscrew 3 8 16 x 1 1 4 Lg ...

Страница 13: ... N176 43B N176 43B N176 44 N176 44 N176 44A N176 44A 11A Venturi 1 N32P 75 N32P 75 N32P 64 N32P 64 N32P 65 N32P 65 11B Nozzle 1 N34P 21 47 N34P 21 47 J34P 44 54 J34P 44 54 J34P 44 54 J34P 44 54 12 Pipe Plug 1 4 NPT Hex Hd U78 941ZPV 3 U78 941ZPV 3 U78 941ZPV 4 U78 941ZPV 4 U78 941ZPV 4 U78 941ZPV 4 13 Capscrew 3 8 16x1 1 2 Lg Hex Hd 2 U30 76ZP U30 76ZP U30 76ZP U30 76ZP 14 Base 1 J4 9 J4 9 J4 9C J...

Страница 14: ...and or strainer are Raise foot valve and or strainer above bottom of water source buried in sand or mud Clean foot valve and strainer Water level is too low for shallow well A deep well jet package may be needed over 25 ft to water setup to deliver water to deliver water Pump does not Water level in well is lower than A deep well jet will be needed if your well is more than 25 7 6M deliver water t...

Отзывы: