background image

7

Pump suctions are hazardous and can trap and drown or disembowel bathers.
Do not use or operate pump, pool or spa if a suction outlet cover is missing,
broken, or loose. Follow the guidelines below for a pump installation which
minimises risk to users or pools and spas.

Entrapment Protection

The pump suction system must provide protection against hazard of suction
entrapment or hair entrapment/entanglement.

Testing and Certif ication

Suction outlet covers must have been tested by a nationally recognised
testing laboratory and found to comply with the latest AS1926.3 standard or
ASME/ANSI specification for Suction Fittings For Use in Swimming Pools,
Spas, Hot Tubs, and Whirlpool Bathtub Applications.

Outlets Per Pump

Provide at least two hydraulically balanced main drains, with covers, for each
swimming pool pump suction line. The centres of the main drains (suction
fittings) must be at least 800mm apart.
The system must be built so that it cannot operate with the pump drawing
water from only one main drain (that is, there must be at least two main drains
connected to the pump whenever it is running). However, if two main drains
run into a single suction line, the single suction line may be equipped with a
valve which will shut off both main drains from the pump.
More than one pump can be connected to a single suction line as long as the
requirements above are met.

Water Velocity

The maximum water velocity through any suction outlet must comply with
the latest AS1926.3 Standard or ASME/ANSI Specification for Suction
Fittings For Use in Swimming Pools, Spas, Hot Tubs, and Whirlpool Bathtub
Applications.

L300216_SilentFlo_OM_2012

Monday, 17 December 2012 1:32:22 PM

Содержание silentflo

Страница 1: ...should contact the distributor manufacturer for the correct advice before proceeding For the Installation Operation and Service of SilentFlo Pool Pump The pump must be supplied from a circuit with the...

Страница 2: ...g 4 Pump Mount 5 Tefon Taping Instructions 6 Fittings 6 Pool Outlets 6 Entrapment Protection 7 Testing and Certifcation 7 Outlets per Pump 7 Water Velocity 7 Electrical 8 Operation 9 Priming Pump 10 S...

Страница 3: ...n to suit 50mm I D PVC pipe to AS NZS 1477 Outlet Discharge ABS Barrel Union to suit 50mm I D PVC pipe to AS NZS 1477 Max Working Pressure 260 kPa Water Temperature Range 5 C 38 C IP Rating IPX5 Elect...

Страница 4: ...n cause explosion Ensure all air is out of the system before operating or testing equipment Silentflo is electrically connected Ensure that it is isolated from electrical supply during installation an...

Страница 5: ...re it is ready for operation Remove trap lid and retighten hand tight only Fire and burn hazard Modern motors run at high temperatures To reduce risk of re do not allow leaves debris or foreign matter...

Страница 6: ...asteners 3 Allow pump suction inlet height to be as far below water level as possible 4 Allow use of short direct suction pipe to reduce friction losses 5 Allow for shut off valves in suction and disc...

Страница 7: ...p as possible To avoid a strain left by a gap at the last connection start all piping at the pump and run pipe away from the pump Never use a suction pipe smaller than pump suction connections 2 50mm...

Страница 8: ...Outlets Per Pump Provide at least two hydraulically balanced main drains with covers for each swimming pool pump suction line The centres of the main drains suction ttings must be at least 800mm apart...

Страница 9: ...al system Do not use extension leads as they are unsafe in and around the Pool Zone Incorrect voltage can cause re or seriously damage pump and voids warranty Voltage at pump must not be more than 6 a...

Страница 10: ...AYS have close adult supervision Pump suction is hazardous and can trap and drown or disembowel bathers Do not use or operate pump pool spas if a suction outlet cover is missing broken or loose Follow...

Страница 11: ...equipment O ring contains a permanent internal lubricant If the o ring needs replacement insist on genuine Onga service parts Clean and inspect o ring reinstall on trap Replace trap lid turn clockwis...

Страница 12: ...t and clean Ensure all holes in basket are clear ush basket with water and replace in trap with large opening at pipe connection port between ribs provided If basket is replaced backwards the cover wi...

Страница 13: ...from sucking air Suction lift of 3 to 6 metres will reduce performance Suction lift of more than 6 metres will prevent pumping and cause pump to lose prime In either instance move the pump closer vert...

Страница 14: ...appliance that is known to work to check power outlet Blown fuse Circuit breaker Check and call electrician if necessary Motor burnt out due to voltage spike or fooded by water The motor may need repl...

Страница 15: ...EMBLY 19 BARREL UNION KIT INCLUDES 19a 19b 19c x2 19a COLLAR UNION 2 SLIP 19b COLLAR UNION 2 19c ORING Collar Union 20 BASE 21 SCREW 5 16 14 x 1 22 MOTOR PAD BASE KIT INCLUDES 19 20 21 1 MOTOR SF55010...

Страница 16: ...has been made to publish the correct details in this data sheet No responsibility will be taken for errors omissions or changes in product specifications Pentair Water reserves the right to change spe...

Отзывы: