Pentair S40093 Скачать руководство пользователя страница 3

Limited Warranty

BERKELEY warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free 
from defects in material and workmanship for the Warranty Period shown below. 

Product

Warranty Period

Water Systems:

Water Systems Products — jet pumps, small centrifugal pumps, submersible pumps and 
related accessories

whichever occurs first: 
12 months from date of original installation, or 
18 months from date of manufacture

Pro-Source

®

 Composite Tanks

5 years from date of original installation

Pro-Source

®

 Steel Pressure Tanks

5 years from date of original installation

Pro-Source

®

 Epoxy-Lined Tanks

3 years from date of original installation

Sump/Sewage/Effluent Products

12 months from date of original installation, or 
18 months from date of manufacture

Agricultural/Commercial:
Centrifugals – close-coupled motor drive, frame mount, SAE mount, engine drive, VMS, 
SSCX, SSHM, solids handling, submersible solids handling

12 months from date of original installation, or 
24 months from date of manufacture

Submersible Turbines, 6” diameter and larger

12 months from date of original installation, or 
24 months from date of manufacture

Our limited warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, 
improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase 
power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, 
ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.
Your only remedy, and BERKELEY’s only duty, is that BERKELEY repair or replace defective products (at BERKELEY’s choice). You 
must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing 
dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has 
expired. This warranty is not transferable.
BERKELEY SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED 
WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR 
A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION 
PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an 
implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and 
You may also have other rights which vary from state to state.
This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011.

In the U.S.: BERKELEY, 293 Wright St., Delavan, WI  53115 

In Canada: 269 Trillium Dr., Kitchener, Ontario N2G 4W5

Warranty 3

Содержание S40093

Страница 1: ...COM PH 888 782 7483 owner s Manual Self Priming Centrifugal Pumps 2013 Pentair Ltd All Rights Reserved BE976 Rev 02 22 13 1362 1111 LT Series Installation Operation Parts For further operating instal...

Страница 2: ...s when servicing pump allow it to cool for 20 minutes after shut down before handling Do not allow pump or any system component to freeze To do so will void warranty Pump water only with this pump Per...

Страница 3: ...single phase power through a phase converter will void the warranty Note also that three phase motors must be protected by three leg ambient compensated extra quick trip overload relays of the recomme...

Страница 4: ...fficient size Pipe submerged less than 4 x D will cause vortexing Long suction run Valve Unsupported Pipe Misaligned pipe causes air leaks high spots along the suction line result in air pockets Offse...

Страница 5: ...pliances on it Wiring 1 Install ground wire and maintain this pump in ac cordance with your local electrical code and all other codes and ordinances that apply Consult your local building inspector fo...

Страница 6: ...cement of shaft seal after a reasonable period of operation see Page 8 Lubricate motor according to motor manufacturer s in structions Periodic greasing is required for most motors TABLE I Recommended...

Страница 7: ...Remove motor hold down bolts and bolts holding adapter seal plate Ref No 6 Repair Parts to pump body Ref No 20 Slide motor adapter seal plate and impeller Ref No 12 backward to clear pump body 5 Remov...

Страница 8: ...revent shaft and sleeve from freezing together when pump is in service 9 Remount adapter seal plate to motor being careful not to scratch seal face 10 Apply liquid soap to inside diameter and outside...

Страница 9: ...ter Slinger 230 460V Three Phase 1 C69 16 C69 15 C69 16 C69 15 5 Capscrew 3 8 16 x 7 8 Lg 8 6 Adapter 1 C2 66 7 Gasket Adapter 1 C20 46 8 Lockwasher 3 8 4 9 Capscrew 3 8 16 x 1 Lg 4 10 Shaft Seal 1 U9...

Страница 10: ...e Washer 1 C43 15SS 4 Machine Screw 1 4 20 x 1 2 1 5 Pipe Plug 1 4 NPT Sq Hd 1 6 Suction Flange 2 NPT 1 C3 22A Suction Flange 2 1 2 NPT 1 C3 74 Suction Flange 3 NPT 1 C3 74B Nut 1 4 20 Hex 1 35407 007...

Страница 11: ...This page intentionally left blank...

Страница 12: ......