S06 UNIT CHARACTERISTICS
UNIT
300W 115V
300W 230V
500W 115V
500W 230V
CATALOG NUMBER
Indoor Model without Communications Board (°C Controller)
S060316G031
S060326G031
S060516G031
S060526G031
Indoor Model with Communications Board (°C Controller)
S060316G041
S060326G041
S060516G041
S060526G041
Indoor Model without Communications Board (°F Controller)
S060316G050
S060326G050
S060516G050
S060526G050
Indoor Model with Communications Board (°F Controller)
S060316G060
S060326G060
S060516G060
S060526G060
COOLING PERFORMANCE
Total L35 L35, 50Hz, according to DIN EN 14511 (Watt)
370
370
550
550
Cooling performance L35 L35 (Watt) 50/60Hz
370 / 420
370 / 420
550 / 640
550 / 640
Cooling performance L35 L50 (Watt) 50/60Hz
190 / 230
190 / 230
320 / 380
320 / 380
Refrigerant
R134a
R134a
R134a
R134a
Refrigerant Charge (g)
133
128
162
162
Max. allowable operating pressure (p. max.) bar
28
28
28
28
Operating Temperature Range (Min/Max °C)
10 / 52 (50Hz)
10 / 55 (60Hz)
10 / 55
10 / 55
10 / 55
Operating Temperature Range (Min/Max °F)
50 / 126 (50Hz)
50 / 131 (60Hz)
50 / 131
50 / 131
50 / 131
Setting Temperature Range (Min. / Max. °C Controller )
20 / 55
20 / 55
20 / 55
20 / 55
Setting Temperature Range (Min. / Max. °F Controller)
72 / 120
72 / 120
72 / 120
72 / 120
Airflow at 0 Static Pressure:
Internal loop (m³/h)
109 / 124
109 / 124
197 / 233
197 / 233
External loop (m³/h)
129 / 156
129 / 156
189 / 219
189 / 219
Duty Cycle
100%
100%
100%
100%
ELECTRICAL DATA
Rated Voltage (Volt)
100 / 115
230
115
230
Phase
1~
1~
1~
1~
Frequency (Hz)
50/60
50/60
50/60
50/60
Operating Range
+/- 10%
+/- 10%
+/- 10%
+/- 10%
Max power Consumption 50/60Hz L35 L35 (Watt)
270 / 300
300 / 320
450 / 470
450 / 480
Max power Consumption 50/60Hz L35 L50 (Watt)
280 / 320
330 / 350
490 / 540
510 / 540
Max. Nominal Current (Amps)
4.0 / 3.8
1.8 / 1.7
6.5 / 6.1
2.6 / 2.9
Starting Current (Amps)
13 / 13
6.0 / 6.0
21 / 20
9.0 / 6.0
Pre-fuse T (Amps)
15
15
15
15
Agency Approvals
UL listed, cUL listed, GOST, CE
Power Input Description
Terminal Block
PERFORMANCE FACTOR (EER), 50Hz, DIN EN 14511
Cooling Performance L35 / L35
1.37 / 1.40
1.23 / 1.31
1.22 / 1.36
1.24 / 1.35
Cooling Performance L35 / L50
0.68 / 0.70
0.58 / 0.65
0.64 / 0.70
0.62 / 0.70
ENCLOSURE PROTECTION
IP Code (External loop / Internal loop)
IP34 / IP54
IP34 / IP54
IP34 / IP54
IP34 / IP54
CONTROLLER
Description
Smart controller with display
Controller Location
Ambient side
Factory Default Setpoint (°C Controller)
35
35
35
35
Factory Default Setpoint (°F Controller)
80
80
80
80
SOUND LEVEL
At 1 M (dBA)
66
66
70
70
UNIT CONSTRUCTION
Material
Steel
Steel
Finish
RAL 7035
RAL 7035
UNIT DIMENSIONS
Height (mm)
550
550
550
550
Width (mm)
280
280
280
280
Depth (mm)
140
140
206
206
Weight (kg)
13
13
15
15
Содержание S06
Страница 9: ... 2015 Pentair Equipment Protection 89116616 9 Figure 3 Figure 4 Figure 5 Figure 6 ...
Страница 17: ... 2015 Pentair Equipment Protection 89116616 17 S06 WIRE DIAGRAM 300 500W ...
Страница 23: ... 2015 Pentair Equipment Protection 89116616 23 S10 MODELS 1000 1500W S10 SCHEMATICS 1000W 115V 230V 1000W 460V ...
Страница 24: ... 2015 Pentair Equipment Protection 89116616 24 1500W 115V 1500W 230V ...
Страница 25: ... 2015 Pentair Equipment Protection 89116616 25 1500W 460V 89107589 REV G ...
Страница 26: ... 2015 Pentair Equipment Protection 89116616 26 S10 WIRE DIAGRAMS 1000W 115V 230V ...
Страница 27: ... 2015 Pentair Equipment Protection 89116616 27 1000W 460V ...
Страница 28: ... 2015 Pentair Equipment Protection 89116616 28 1500W 115V ...
Страница 29: ... 2015 Pentair Equipment Protection 89116616 29 1500W 230V ...
Страница 30: ... 2015 Pentair Equipment Protection 89116616 30 1500W 460V 89107588 REV H ...
Страница 37: ... 2015 Pentair Equipment Protection 89116616 37 S16 MODELS 2000 2500W S16 SCHEMATICS 2000W 115V 2000W 230V ...
Страница 38: ... 2015 Pentair Equipment Protection 89116616 38 2000W 460V 89107589 REV G 2500W 115V ...
Страница 39: ... 2015 Pentair Equipment Protection 89116616 39 2500W 230V 2500W 460V 89107593 REV G ...
Страница 40: ... 2015 Pentair Equipment Protection 89116616 40 4000W 460V ...
Страница 41: ... 2015 Pentair Equipment Protection 89116616 41 S16 WIRE DIAGRAMS 2000W 115V ...
Страница 42: ... 2015 Pentair Equipment Protection 89116616 42 2000W 230V ...
Страница 43: ... 2015 Pentair Equipment Protection 89116616 43 2000W 460V 89107588 REV H ...
Страница 44: ... 2015 Pentair Equipment Protection 89116616 44 2500W 115V ...
Страница 45: ... 2015 Pentair Equipment Protection 89116616 45 2500W 230V ...
Страница 46: ... 2015 Pentair Equipment Protection 89116616 46 2500W 460V 89107592 REV H ...
Страница 47: ... 2015 Pentair Equipment Protection 89116616 47 4000W 460V ...
Страница 49: ... 2015 Pentair Equipment Protection 89116616 49 4000W W DKE dKZ ϰϲϬs KE zͿ Ͳ W d WKZd ...
Страница 58: ... 2015 Pentair Equipment Protection 89116616 58 NOTES ...
Страница 63: ... 2015 Pentair Equipment Protection 89116616 63 NOTES ...