User Guide Riva Viridion
Ref. MKT-UG-044 / A - 02.06.2020
3.3.
Softener’s available options
3.3.1. Mixing device
The valve can be equipped with a mixing device whose function is to regulate the hardness of the water at the outlet.
3.3.2. Probe
The SFE-EV-VIRIDION controller can grant significatively water savings, with a probe, during slow rinse and fast rinse phases
by comparing the instantaneous conductivity of the water (Ci) flowing through valve drain with the one previously recorded.
4 .
Installation
4.1.
Installation environment
4.1.1. General
• Use only brine salts designed for water softening. Do not use ice melt salt, block, or rock salts;
• follow State and local codes for water testing. Do not use water that is micro-biologically unsafe or of unknown quality;
• when filling media tank, first place the valve in backwash position, then do not open water valve completely. Fill tank slowly
to prevent media from exiting the tank;
• when installing the water connection (bypass or manifold) connect to the plumbing system first. Allow heated parts to cool
and cemented parts to set before installing any plastic parts. Do not get primer or solvent on o-rings, nuts, or the valve.
4.2.
Softener connection to piping
TIP
To prevent your softener from incoming sediment and iron particles, Pentair recommends the
installation of a 100 μm pre-filter upstream the unit.
MANDATORY
The unit should be installed in accordance with the manufacturer’s recommendations and meet all
applicable plumbing codes.
4.2.1. Installation layout
Hard water pipe
Soft water pipe
½" overflow line
Power supply
Drain
Softener
Max 6.0 m for 12.7 mm (½") drain line
Max 12.2 m for 19 mm (¾") drain line
Drain pipe