Pentair PRF-RO Скачать руководство пользователя страница 3

LOCATION OF SYSTEM

The reverse osmosis system is designed for installation under a sink, 

usually in the kitchen or bathroom. The RO assembly can be placed on 

the cabinet floor in any position that does not apply pressure on the 

disconnect elbows. The RO product water faucet installs on the sink 

or on the countertop next to the sink.
The RO system can also be located in a location away from the 

faucet. A nearby water source and drain point are required.

NOTE: Keep the lengths of tubing short.  Longer lengths of tubing will 

decrease system performance.  A booster pump can be used 

on the supply line.

NOTE: All plumbing should be done in accordance with state and 

local plumbing codes. 

Some codes may require installation by a licensed plumber. 

Check with the local plumbing authority prior to installation.

WARNING:

 All components and tubing should be located in an 

area which is not exposed to freezing temperatures. 

Do not expose unit or tubing to direct sunlight.

Water Supply:  To provide supply water to the RO system inlet, a feed 

supply fitting is required or install pipe fittings as needed. The feed 

water valve should be located as close to the manifold assembly 

as possible. USE A POTABLE COLD WATER SUPPLY ONLY. Softened 

water is preferred as it will extend the life of the RO membrane 

element.

THE BASIC REVERSE OSMOSIS SYSTEM cont.

Faucet

with Air Gap

Inlet-1/2" Natural

Feed Water Valve

Cold Water Line Only

Carbon Postfilter

Waste Concentrate

3/8" Black

Drain - 1/2" Red

Product - 3/8" Blue

Drain Coupling

Install above P trap

Locking Bar

Keep to Minimum

Prefilter

RO Membrane

Support Leg (sump wrench)

Manifold

Elbow

Connectors

Feed Pressure Gauge

Drain Point:  A suitable drain point is needed for reject water from 

the RO system. A floor drain, laundry tub, standpipe, sump, etc. are 

all acceptable. If discharging into the utility sink or standpipe, an air 

gap of greater than 1/2-inches above the flood rim must be provided. 

A sink p-trap drain adapter is included to install as an optional drain 

point where codes permit. 
Do not connect the system drain line to the dishwasher drain or near 

the garbage disposal. Back pressure from these units may cause the 

air gap to overflow.
Faucet:  The faucet should be placed near the sink where drinking 

water is normally obtained. Convenience of use (filling of water 

pitchers and glasses) and an open area beneath the faucet under 

the sink for attaching product and drain tubing are considerations. 

A 2-inch diameter flat surface is required above and below the 

installation site. The thickness of mounting surface should not exceed 

1-1/4-inches. Avoid any strengthening webbing on the underside of 

the sink.
RO Manifold Assembly:  The manifold can be installed on either the 

right or left side of the under-sink area or cabinet. Installation in the 

basement is also an option. One possible location is near the laundry/

utility sink where cold potable water and drain access are close. The 

location chosen should allow adequate clearance and accessibility 

for membrane element changes. 
In restricted under-sink areas, it may be easier to install the faucet 

first. Allow adequate tubing lengths for final system placement.

Figure 2  Typical Under-Sink Installation

3

Содержание PRF-RO

Страница 1: ...properly rinse out the preservative The preservative is not harmful but makes the product water taste objectionable Rinsing the membrane also acts a performance conditioner All new membranes will reac...

Страница 2: ...W TUBING INSTALL KIT PN 1255736 3 8 BLACK TUBING 4 ft 3 8 BLUE TUBING 4 ft 1 2 NATURAL TUBING 4 ft 1 2 RED TUBING 3 ft SILICONE LUBRICANT FEED DISCONNECT ELBOW WHITE PN 3035307 1 pc PERMEATE DISCONNEC...

Страница 3: ...Coupling Install above P trap Locking Bar Keep to Minimum Prefilter RO Membrane Support Leg sump wrench Manifold Elbow Connectors Feed Pressure Gauge Drain Point A suitable drain point is needed for r...

Страница 4: ...Air Gap Required Inlet 1 2 Natural Drain 3 8 Black Feed Water Valve Cold Water Line Only Carbon Postfilter Product 3 8 Blue RO Assembly Keep to Minimum THE BASIC REVERSE OSMOSIS SYSTEM cont Figure 3...

Страница 5: ...Line Only Feed Pressure Gauge RO Assembly External Prefilter Product Storage Tank To Point of Use Vented to Atmosphere Liquid level float sensor to control feed solenoid valve Feed Solenoid Valve Figu...

Страница 6: ...d that there is space underneath for tubing 2 If drilling is needed make a 1 1 2 inch diameter hole WARNING To avoid damaging a sink consult a qualified plumber or installer for the proper method of d...

Страница 7: ...cure the connection NOTE When sliding tubing into the drain adapter inlet wet the tubing Water will help the tubing slide into the rubber inlet Feed Pressure Gauge The supplied pressure gauge can be c...

Страница 8: ...ng instructions describe the method and locations for lubrication Six packets of silicone lube are supplied One packet should be completely used to lubricate the O ring contact surfaces in the 3 manif...

Страница 9: ...eats in the manifold that come in contact with the sump and element O rings Refer to Connection Lubrication on page 8 NOTE To properly lubricate the O ring contact area a film of clean silicone grease...

Страница 10: ...ening the faucet CAUTION Even with the water supply turned off the membrane and prefilter sumps will contain a considerable amount of water By positioning the RO assembly in a sink or tub most of the...

Страница 11: ...ubing back approximately 1 4 inch prior to connecting the new postfilter Make sure flow direction arrow aligns with water path Reinsert tubing and collect locks 11 Re connect the fittings to the manif...

Страница 12: ...78 C Inlet TDS 50 mg L 2 000 mg L Inlet Hardness 0 mg L 0 grain 171 mg L 10 grain Inlet Chlorine 0 mg L 1 0 mg L Inlet Iron 0 mg L 0 1 mg L Inlet Manganese 0 mg L 0 05 mg L Inlet pH 4 10 Inlet Turbidi...

Страница 13: ...f flow into the postfilter is acceptable replace postfilter Leak or kink in product line Find and repair leak or kink Concentrate water runs to drain after faucet shut off Plugged prefilter Replace pl...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...2010 Pentair Residential Filtration LLC 4000413 Rev B JE10...

Отзывы: