Pentair PRF-RO Скачать руководство пользователя страница 2

THE BASIC REVERSE OSMOSIS SYSTEM cont.

COMPLETE

MANIFOLD

PN 4000445 (1 pc)

SUPPORT

LEG

PN 3038021 

(1 pc)

SUMP

& SEAL

SUMP

PN 1239705 

(3 pcs)

O-RING

PN 1240326 

(3 pcs)

ELEMENT

(TFC-350 IND)

PN 4000569 

(2 pcs)

FITTINGS

& LOCKING BAR

INSTALL KIT

PN 4000330

LOCKING BAR

DISCONNECT

PN 3038026 (1 pc)

3/8-INCH COLLET

LOCK CLIP

PN 3038239 (5 pcs)

1/2-INCH COLLET

LOCK CLIP

PN 3038250 (2 pcs)

DRAIN

DISCONNECT

ELBOW - BLACK

PN 3035306 (1 pc)

SOME CONFIGURATIONS MAY NOT INCLUDE ALL 

COMPONENTS LISTED BELOW

TUBING

INSTALL KIT

PN 1255736

3/8" BLACK

TUBING (4 ft)

3/8" BLUE

TUBING (4 ft)

1/2" NATURAL

TUBING (4 ft)

1/2" RED

TUBING (3 ft)

SILICONE LUBRICANT

FEED

DISCONNECT

ELBOW - WHITE

PN 3035307 (1 pc)

PERMEATE

DISCONNECT

ELBOW - BLUE

PN 3035305 (1 pc)

FAUCET

CONNECTION

FITTING

PN 3038251 (1 pc)

SILICONE

LUBRICANT

SGL USE TUBE

PN 1013501 (6 pc)

DRAIN BOA

KIT

PN 1240564 

(1 pc)

AIR-GAP

FAUCET KIT

PN 3020487 

(1 pc)

CARBON 

PRE-FILTER

PN 303833 

(1 pc)

SEDIMENT 

PRE-FILTER

PN 1266690 

(1 pc)

CARBON

POST-FILTER

PN 255526-09 

(1 pc)

Note: For use 

with chlorinated 

water supplies.

Note: For use with 

non-chlorinated 

water supplies.

ADDITIONAL COMPONENTS

(see table below)

FEED PRESSURE

GAUGE

PN 3002494 (1 pc)

Figure 1   

2

Содержание PRF-RO

Страница 1: ...properly rinse out the preservative The preservative is not harmful but makes the product water taste objectionable Rinsing the membrane also acts a performance conditioner All new membranes will reac...

Страница 2: ...W TUBING INSTALL KIT PN 1255736 3 8 BLACK TUBING 4 ft 3 8 BLUE TUBING 4 ft 1 2 NATURAL TUBING 4 ft 1 2 RED TUBING 3 ft SILICONE LUBRICANT FEED DISCONNECT ELBOW WHITE PN 3035307 1 pc PERMEATE DISCONNEC...

Страница 3: ...Coupling Install above P trap Locking Bar Keep to Minimum Prefilter RO Membrane Support Leg sump wrench Manifold Elbow Connectors Feed Pressure Gauge Drain Point A suitable drain point is needed for r...

Страница 4: ...Air Gap Required Inlet 1 2 Natural Drain 3 8 Black Feed Water Valve Cold Water Line Only Carbon Postfilter Product 3 8 Blue RO Assembly Keep to Minimum THE BASIC REVERSE OSMOSIS SYSTEM cont Figure 3...

Страница 5: ...Line Only Feed Pressure Gauge RO Assembly External Prefilter Product Storage Tank To Point of Use Vented to Atmosphere Liquid level float sensor to control feed solenoid valve Feed Solenoid Valve Figu...

Страница 6: ...d that there is space underneath for tubing 2 If drilling is needed make a 1 1 2 inch diameter hole WARNING To avoid damaging a sink consult a qualified plumber or installer for the proper method of d...

Страница 7: ...cure the connection NOTE When sliding tubing into the drain adapter inlet wet the tubing Water will help the tubing slide into the rubber inlet Feed Pressure Gauge The supplied pressure gauge can be c...

Страница 8: ...ng instructions describe the method and locations for lubrication Six packets of silicone lube are supplied One packet should be completely used to lubricate the O ring contact surfaces in the 3 manif...

Страница 9: ...eats in the manifold that come in contact with the sump and element O rings Refer to Connection Lubrication on page 8 NOTE To properly lubricate the O ring contact area a film of clean silicone grease...

Страница 10: ...ening the faucet CAUTION Even with the water supply turned off the membrane and prefilter sumps will contain a considerable amount of water By positioning the RO assembly in a sink or tub most of the...

Страница 11: ...ubing back approximately 1 4 inch prior to connecting the new postfilter Make sure flow direction arrow aligns with water path Reinsert tubing and collect locks 11 Re connect the fittings to the manif...

Страница 12: ...78 C Inlet TDS 50 mg L 2 000 mg L Inlet Hardness 0 mg L 0 grain 171 mg L 10 grain Inlet Chlorine 0 mg L 1 0 mg L Inlet Iron 0 mg L 0 1 mg L Inlet Manganese 0 mg L 0 05 mg L Inlet pH 4 10 Inlet Turbidi...

Страница 13: ...f flow into the postfilter is acceptable replace postfilter Leak or kink in product line Find and repair leak or kink Concentrate water runs to drain after faucet shut off Plugged prefilter Replace pl...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...2010 Pentair Residential Filtration LLC 4000413 Rev B JE10...

Отзывы: