background image

ModEls

 

Model

Part # 

(120v/60Hz)

Part # 

(220v/50Hz)

UVS-110

163003

163004

UV-110

163005

163006

UV-120

163007

163008

UVBB-120

163009

163010

APPlicATioN

Ultraviolet Water Disinfection

sPEcificATioNs

Models: UVs-110

UV-110

UV-120 UVBB-120

Maximum Operating 

Pressure

65 psi

65 psi

65 psi

65 psi

Temperature 

Range

40-100˚F 

(4.4-37.8˚C)

40-100˚F 

(4.4-37.8˚C)

40-100˚F 

(4.4-37.8˚C)

40-100˚F 

(4.4-37.8˚C)

Flow Rate @ 60 psi 

(4.1 bar)

1 gpm 

(3.8 Lpm)

2 gpm 

(7.6 Lpm)

8 gpm 

(30 Lpm)

15 gpm 

(56 Lpm)

Voltage (Domestic) 120v/60Hz 120v/60Hz 120v/60Hz 120v/60Hz
Voltage (Int’l)

220v/50Hz 220v/50Hz 220v/50Hz 220v/50Hz

cBU cartridge 

The UVS-110 and the UV-110 are supplied with a carbon block filter 
cartridge which reduces sediment, bad taste and odor.

GENErAl PrEcAUTioNs

 Always disconnect the UV from the power 

source. follow the procedures provided in 

this manual. improper handling can result in 

death or serious injury.

 do not look directly at the UV lamp. This can 

cause retina/eye damage.

 do not touch the UV bulb. Any fingerprints or 

dirt will reduce the efficiency of the bulb and 

may cause it to explode.

 observe caution when inserting quartz sleeve 

to prevent breakage and cracking, which may 

result in injury and damage to unit.

NoTE: When handling the UV bulb hold only the plastic-

covered ends of the bulb. if the bulb has been touched, 

remove bulb and clean with alcohol before reinserting.

  if water pressure exceeds 65 psi, a pressure 

regulator, set at less than 65 psi, must be installed 

before the Ultraviolet system.

  install on cold water lines only.
  do not install where system is exposed to  

direct sunlight.

  do not use wicking or sealing agents for fitting 

connections. Plumbers tape is recommended.

  This system must be protected from 

freezing which can cause cracking of the 

filter housing and water leakage.

  Because of the product’s limited service life, 

and to prevent costly repairs or possible water 

damage, we strongly recommend that the bottom 

of all opaque housings be replaced every ten 

years. if the bottom of your housing has been 

in use for more than this period, it should be 

replaced immediately. date the bottom of any 

new or replacement housing to  indicate the next 

recommended replacement date.

NoTE: filter cartridge life varies depending on filter type, 

usage and water conditions

.

for the UVs-110 and UV-110

Allow a minimum of 12 inches clearance under the filter for 

changing the cartridge, and above the system to allow the UV 

bulb to be changed.

for the UV-120 and UVBB-120

Allow a minimum of 20 inches clearance under the filter for 

changing the cartridge, and above the system to allow the UV 

bulb to be changed.

cArTridGE rEPlAcEMENT 
(for UVs-110 and UV-110 only)

Your cartridge should be replaced when there is a noticeable 

drop in water flow at the faucet or tap, and/or when unpleasant 

odors return (approximately every 6-9 months).
1.  Turn off water supply to the system.
2.  Open faucet to relieve water pressure to the housing. 
3.  Unscrew housing from cap. If housing sticks or is difficult to 

open use an Pentek spanner wrench.

4.  Remove used cartridge from housing, remove plastic

 

sleeve 

and discard cartridge.

5.  Remove O-ring from groove below the threads of the 

housing and wipe groove and O-ring clean. Lubricate O-ring 

with silicone grease. Place O-ring back into the groove. 

With two fingers wipe or press O-ring down into the groove. 

Note: This step is important to ensure a proper filter seal. 

Make sure that the o-ring is seated level in the groove.

6.  Insert a new cartridge into the sump making sure that it 

slips down over the sump standpipe.

7.  Remove gasket from cartridge end and slide plastic

  

sleeve into center of cartridge then replace gasket on top  

of cartridge.

8.  Screw the sump onto the cap and hand-tighten. Do not over-

tighten. Make sure that the cap slips over the cap standpipe.

9.  Turn on the water supply to allow the unit to slowly fill  

with water.

10. Check for leaks before leaving installation.
11. Each time that you use water from your unit for drinking or 

cooking purposes, it is recommended that you run (flush) 

the tap for at least 10 seconds prior to using water. This is 

particularly important if the water tap is not used daily.

UV lAMP rEPlAcEMENT

1.  Turn off all electrical power to the system by unplugging or 

throwing the circuit.

2.  Unscrew the UV control module from the mounting bracket (4 

screws) for Models UV-110, UV-120 and UVBB-120. For Model UVS-

100, slide mounting bracket retainer to allow access to the UV bulb.

3.  Slide the old bulb out and unplug from the control module.

Note: Hold the UV lamp only by the plastic covered ends of  

the bulb. 

4.  Carefully discard the old UV lamp.
5.  Holding the new UV lamp only by the plastic covered ends of the 

bulb, plug the new UV lamp into the control module or power cord. 

Slide the new bulb into the cartridge housing and reattach UV 

control module or secure mounting bracket retainer (depending  

on model).

6.  Restore electrical power to unit.
7.  Check for leaks.

2 • 

PENTEK

®

 UV Water Systems Instruction Manual

Отзывы: