3 Cleaning Cycle Interval: Press “Cleaning Cycle Interval” to display the current cleaning
cycle interval setting. The value in cubic meters (metric units) to treat between cleaning
cycles will be displayed for five seconds. While the value is being displayed, press the button
to increase the value. Press and hold the button to rapidly advance the value. Press and
hold the button to rapidly advance the value. Release the button when the desired value is
displayed. The value will be stored in memory after five seconds.
Range: 0.4 - 9.5 cubic meters
Default: 1.0 cubic meters
4 Backflush:
• Press and release “Backflush” to program a delayed cleaning cycle. The system will
backwash at the next scheduled cleaning cycle. Repeat procedure to disable the scheduled
cleaning cycle. The display indicator dot blinks when a delayed cleaning cycle is scheduled.
• Press and hold for three seconds to initiate an immediate cleaning cycle. The control cycles
to the backwash cycle step. The control will proceed through a complete cleaning cycle. A
cascading symbol (- -) will be displayed until the cycle is complete.
NOTE: If a button is not pushed for five seconds, the controller returns to normal operation
mode.
Pushing the Backflush button immediately returns the controller to normal operation.
Quick Cycling
Press and hold for three seconds “Backflush” to initiate an immediate cleaning cycle. The
control will cycle to the backwash cycle step.
1. Press and release “Backflush” to display “C1” (backwash).
2. Simultaneously press then release “Backflush” and “Time of day” to move the control to
the next cycle step, “C2” (rinse).
NOTE: The time may be displayed for 5 seconds.
3. Repeat steps 2 and 3 to cycle through each position.
Quick Cycle to Service Position
Simultaneously press “Backflush” and “Time of day” and hold for three seconds during any
cleaning cycle step. The control will skip the remaining cycle steps and return to the service
position. The time of day will be displayed when the control reaches the service position.
Calendar Override: To set time duration between cleaning cycles to ensure proper
functioning of the filter in the event of a flow sensor malfunction, press and hold “Backflush”
and “Cleaning Cycle Interval” for three seconds. The value in days between cleaning cycles
will be displayed for five seconds. While the value is being displayed, press the button to
increase the value. Press and hold the button to rapidly advance the value. Release the
button when the desired value is displayed. The value will be stored in memory after five
seconds.
Range: 8 hours (0.3 days) - 30 days; 0 to disable
Default: 0 (disabled)