101
Appendix
SECTION 14: Appendix
Ventilated
Well Cap
Submersible
Cable
Pitless
Adapter
Check
Valve
Tape Cable
To Pipe
Add Torque Arrestor
(especially needed with
plastic pipe)
Pump
Motor
Control Box
(3-wire Models)
Electrical Disconnect
Pre-charged Tank
Pressure Switch
Pressure Gauge
To House Service
Relief
Valve
Union
Gate Valves
“Good” System
Features
• Pressure Switch
• Wire, (10-2 w/ground)
• 1.5 HP, 20-22 gpm pump
• 1.5 HP, 2-wire motor
• 85 gal. Tank
• Optional Motor Protection (SPP-233P)
Benefits
• Cost
• Simple to use
• PENTEK PSC motor offers lower
operating cost
“Better” System
Features
• Control Box
• Pressure Switch
• Wire, (10-3 w/ground)
• 1.5 HP, 20-22 gpm pump
• 1.5 HP, 3-wire motor
• 85 gal. Tank
• Optional Motor Protection (SPP-233P)
Benefits
• Capacitors and switches can be
replaced without removing pump
• CSCR control offers higher efficiency
• Higher starting torque than 2-wire
“Best” System
Features
• VFD
• Pressure Transducer
• Wire, (12-3 w/ground)
• 1.5 HP, 20-22 gpm pump
• 1.5 HP, 3-Phase motor
• 6 gal. Tank
Benefits
• “City-like” pressure
• Lower operating costs
• Soft start/stop
• Motor protection built into VFD
14.2 Choosing A Pump System
A typical well application can be set up using one of three
electrical configurations for single-phase power. The
samples below are based upon a system using a 1.5 HP,
20-22 gpm pump, with 400 feet of wire from electrical
disconnect to the motor. All configurations shown are
suitable methods for residential applications.