I=Indoor, E=Outdoor. Quantity is 1, unless otherwise noted.

Key

Size

Size

Size

Size

Size

Size

Size

No.

Description

2000 I

2450 I

3050 I

3500 I

4050 I

4500 I

5000 I

2200 E

2800 E

3200 E

3600 E

4000 E

4500 E

22.

Lock Washer - 

3

/

8

"

F0010800

F0010800

F0010800

F0010800

F0010800

F0010800

F0010800

(2)

(2)

(2)

(2)

(2)

(2)

(2)

23.

Washer -  

3

/

8

"

F0011100

F0011100

F0011100

F0011100

F0011100

F0011100

F0011100

(2)

(2)

(2)

(2)

(2)

(2)

(2)

24.

Cap Screw

F0015900

F0015900

F0015900

F0015900

F0015900

F0015900

F0015900

3

/

8

" - 16UNC x ¾ "

(2)

(2)

(2)

(2)

(2)

(2)

(2)

25.

Heat Exchanger Baffle Assembly 20010900

20010900

20010900

20010900

20010900

20010900

20010900

(68)

(68)

(68)

(102)

(102)

(102)

(102)

26.

Heat Exchanger Baffle F & R

10534310

10534311

10534312

10534313

10534314

10534315

10534316

(2)

(2)

(2)

(2)

(2)

(2)

(2)

27.

Front & Rear Closure

20006401

20006402

20006403

20006404

20006405

20006406

20006407

(2)

(2)

(2)

(2)

(2)

(2)

(2)

28.

Inside Baffle Assembly   Indoor

20012501

20012502

20012503

20012504

20012505

20012506

20012507

                                       Outdoor

N/A

20012509

20012510

20012511

20012512

20012513

20012514

29.

Flue Panel Assembly, F&R

20011501

20011502

20011503

20011504

20011505

20011506

20011507

(2)

(2)

(2)

(2)

(2)

(2)

(2)

30.

Upper Panel

20011701

20011702

20011703

20011704

20011705

20011706

20011707

F & R (indoor only)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

31.

Flue Diverter Assembly

20012201

20012202

20012203

20012204

20012205

20012206

20012207

(indoor only)

32.

Upper Wing

20006301

20006301

20006301

20006301

20006301

20006301

20006301

F & R, Left (indoor only)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

33.

Upper Wing

20006302

20006302

20006302

20006302

20006302

20006302

20006302

F & R, Right (indoor only)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

34.

Top Panel Assembly

20012301

20012302

20012303

20012304

20012305

20012306

20012307

(indoor only)

35.

Flue End Assembly

20012000

20012000

20012000

20012000

20012000

20012000

20012000

(2)

(2)

(2)

(2)

(2)

(2)

(2)

36.

Upper End Assembly

20011900

20011900

20011900

20011900

20011900

20011900

20011900

(2)

(2)

(2)

(2)

(2)

(2)

(2)

37.

Lower End Panel Assembly

20011800

20011800

20011800

20011800

20011800

20011800

20011800

(2)

(2)

(2)

(2)

(2)

(2)

(2)

38.

Control Mounting Panel

20013700

20013700

20013700

20013700

20013700

20013700

20013700

39.

Control Cover - Front

20018700

20018700

20018700

20018700

20018700

20018700

20018700

40.

Control Box Cover Top

20011200

20011200

20011200

20011200

20011200

20011200

20011200

41.

Pilot Lead Assembly (Johnson)

20035403

20035403

20035403

20035403

20035403

20035403

20035403

Standing Pilot, Nat/Propane

(2)

(2)

(2)

(2)

(2)

Pilot Lead Assembly (Honeywell) 20035404

20035404

20035404

20035404

20035404

20035404

20035404

Standing Pilot, Nat/Propane

(2)

(2)

(2)

(2)

(2)

Pilot Lead Assembly (Johnson)

20035401

20035401

20035401

20035401

20035401

20035401

20035401

IID Pilot, Nat

(2)

(2)

(2)

(2)

(2)

Pilot Lead Assembly (Honeywell) 20035402

20035402

20035402

20035402

20035402

20035402

20035402

IID Pilot, Nat

(2)

(2)

(2)

(2)

(2)

42.

Pilot Shield

20016400

20016400

20016400

20016400

20016400

20016400

20016400

(2)

(2)

(2)

(2)

(2)

43.

Draft Hood Relief

20013801

20013801

20013801

20013801

20013802

20013803

20013804

Baffle - Right (indoor only)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

44.

Draft Hood Relief

20013805

20013805

20013805

20013805

20013806

20013807

20013808

Baffle - Right (indoor only)

(2)

(2)

(2)

(2)

(2)

(2)

(2)

45.

Manual Valve

V0001800

V0001800

V2013800

V2013800

V2013800

V2013900

V2013900

46.

Safety Valve (U.S.)

V0046800

V0046800

V0046900

V0046900

V0046900

V2000500

V2000500

Lubricated Plug Valve (Canada) V0020500

V0020500

V0020600

V0020500

V0020500

V0020500

V0020500

(2)

(2)

(2)

(2)

47.

Operating Valve

V0047800

V0047800

V0047900

V0047700

V0047800

V0047800

V0047800

(2)

(2)

(2)

(2)

Содержание MegaTherm MT 2000

Страница 1: ...sult causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL G...

Страница 2: ...it Checkout 10 3B To Start Up System See Section 3A for Initial Start Up 10 3C To Turn Off Boiler 10 3D Spring and Fall Operation 10 3E WinterOperation 10 3E 1 DrainingBoilerBeforeFreezing 10 3E 2 Imp...

Страница 3: ...the Pentair Water Commercial Pool and Spa technical support see page 2 or your local representative with any problems or questions regarding this equipment Experience has shown that most operating pr...

Страница 4: ...unicating directly through the wall to outside air one within 12 inches of the ceiling the other within 12 inches of the floor Each opening should have a minimum free area of one square inch per 4 000...

Страница 5: ...al draft action of the venting system This can create a health hazard by spilling flue products into the boiler room 6 Avoid oversize vent piping or extremely long runs of the pipe which may cause exc...

Страница 6: ...essure could be an indication of an undersized gas meter and or obstructed gas supply line 6 The correct burner manifold gas pressure is stamped on the rating plate The regulator is preset at the fact...

Страница 7: ...Piping of System to Boiler 1 Be sure to provide gate valves at the inlet and outlet to the boiler so it can be readily isolated for service 2 The pressure relief valve must be installed in the tapped...

Страница 8: ...ic flow control valve will maintain proper flow through the boiler regardless of the reduced water flow due to a dirty or clogged filter 2J Automatic Chlorinators A concentration of chlorine in the bo...

Страница 9: ...tch on the boiler is in the ON position After placing the manual pilot valves in the open position and resetting all safety devices high limit pressure switch Low Water Cutoff etc pilots can be lit fo...

Страница 10: ...pool water temperature automatically 3C To Turn Off Boiler 1 Turn off main electrical switch 2 Close all manual gas valves 3D Spring and Fall Operation When the pool is not going to be used for a lon...

Страница 11: ...eriodic Service Inspect the heat exchanger tubes of the Model MT pool boiler on a regular basis In most areas and under most operating conditions the MT pool boiler will operate for years without accu...

Страница 12: ...Reassemble in reverse order Be sure to replace the heat exchanger baffles 6 The gas and electric controls installed on the boilers are designed for both dependable operation and long life But the safe...

Страница 13: ...is indicated replace coil or operator Boiler is Pounding Knocking or Emitting Steam from Relief Valves Possible Cause What To Do Lower or no water flow This condition is usually caused by lack of adeq...

Страница 14: ...and remaining screws from flue collector extension 12 12 Install middle rear panel 13 13 Install front panel making sure opening for removable panel is square 19 14 Install front stiffener 184 2450 an...

Страница 15: ...MegaTherm Commercial Pool Heating Boiler Page 15 Figure 12 Outdoor Parts Referenced on page 14...

Страница 16: ...sembly 20011301 20011302 20011303 20011304 20011305 20011306 20011307 12 Rear Closure Assembly 20012401 20012402 20012403 20012404 20012405 20012406 20012407 13 Heat Shield Support Bracket 20003201 20...

Страница 17: ...MegaTherm Commercial Pool Heating Boiler Page 17 Figure 13 Parts Identification Indoor parts only For tiles see Figure 15...

Страница 18: ...20012303 20012304 20012305 20012306 20012307 indoor only 35 Flue End Assembly 20012000 20012000 20012000 20012000 20012000 20012000 20012000 2 2 2 2 2 2 2 36 Upper End Assembly 20011900 20011900 2001...

Страница 19: ...shown 2 2 2 2 2 49 b Pilot Relay Standing Pilot W003000 W003000 W003000 W003000 W003000 W003000 W003000 not shown 2 2 2 2 2 50 Pilot Burner Johnson W0034700 W0034700 W0034700 W0034700 W0034700 W00347...

Страница 20: ...1 805 553 5000 Trademarks and disclaimers MegaTherm and the Pentair Commercial Pool and Spa logo are trademarks of Pentair Water Pool and Spa Inc Other trade marks and trade names may be used in this...