10
MAKOSHARK
®
Inground Suction Pool Cleaner
Owner’s Manual
TROUBLESHOOTING
Problem: Cleaner is sluggish or has stopped operating.
Solution: •
Check cleaner for blockage inside the Oscillator chamber. Refer to Maintenance on
page 8.
•
Clean your filter system, empty pump basket and empty skimmer basket.
Refer (Step 1).
•
Inspect the Regulator Valve and flush away any debris buildup.
•
Check hose sections for blockages.
•
Check hose sections for leeks by lifting each section above water.
•
Using your Flow gauge, verify proper water flow to your cleaner. Refer (Step 7).
Problem: Cleaner gets stuck on the steps:
Solution: •
Adjust the Eyeball Diverter of the return flow towards the problem area to guide the
cleaner away from the steps.
•
Verify proper hose length (Step 5) and correct position of the Hose Weight(s) (Step 8).
•
Remove or add one hose section.
•
Using your Flow gauge, verify proper water flow to your cleaner. (Step 7)
•
Using your Flow gauge, Increase or decrease the flow to your cleaner within the
maximum/minimum range (Step 7).
Problem: Cleaner travels in repetitive pattern.
Solution: •
Adjust Eyeball diverters as described in diagrams. (Step 9).
•
Verify proper hose length (Step 5) and correct position of the Hose Weight(s) (Step 8).
•
Remove or add one hose section.
•
Check that the hose sections are straight. Straighten up any bent or coiled hose
sections by laying them in the warm sun for a day or two.
Problem: Cleaner does not transit onto the wall.
Solution: •
Using your Flow gauge, verify proper water flow to your cleaner. Refer (Step 7).
•
Increase the water flow slightly by turning the knob on the adjustable regulator valve.
•
Verify proper hose length (Step 5) and correct position of the Hose Weights (Step 9).
Problem: Cleaner stays in one side of the pool.
Solution: •
Adjust Eyeball diverters as described in diagrams. (Step 9).
•
Adjust Eyeball diverters as necessary to guide the cleaner to the other side of the
pool.
•
Verify proper hose length (Step 5) and correct position of the Hose Weight(s) (Step 8).
•