Optional Vacuum Line Installation

Vacuum Line Installation With Automatic Regulator Valve

in Skimmer.

We recommend the use of the automatic regulator valve to balance water flow between Kreepy Krauly and

the skimmer. When attaching Kreepy Krauly to a dedicated vacuum line, the automatic regulator valve

should be installed in the skimmer.

1. Turn the pool pump off.

2. Close the main drain and all suction lines, except the

skimmer and the vacuum line to which the Kreepy

Krauly will be connected.

3. Thread the snap-lock wall fitting into the end of the

dedicated suction line. Then insert the male end of the 45°

hose connector into the snap-lock fitting. See Figure 10.

NOTE: Use two wraps of Teflon tape around the

threads to ensure easy removal.

4. Place Kreepy Krauly (with the hose and hose weights

assembled and attached) into the pool and allow it to sink

to the floor.

NOTE: You will have to remove the

female/female hose section in this installation.

Continue

to feed the hose vertically down into the pool until it is

completely filled with water and purged of air.

5. Insert the male hose end of the last hose section into the 45° hose connector or directly into the snap-lock

wall fitting.

Reminder: Do not use the female/ female hose section in this installation.

See Figure 10.

6. Screw the threaded compression adapter into the vacuum

connection in the bottom of the skimmer.

NOTE: Use two

wraps of Teflon tape around the threads to ensure easy

removal.

If the opening in the bottom of the skimmer is

not

threaded, use a 2'' hose cone, the 2'' hose cone is not provided

but can be purchased from your Pentair Pool Products dealer.

7. To prevent water from flowing through the top of the

automatic regulator valve, fasten the valve cap onto the top

of the regulator valve. This activates the regulator valve and

assures that an accurate amount of water (25 gpm) will flow

through the vacuum line and the Kreepy Krauly. Without the

valve cap, the automatic regulator valve and the cleaner will

not

function properly. See Figure 12.

8. Press the automatic regulator valve into the threaded compression adapter. See Figure 12.

7

Accessories NOT PROVIDED:

Snap-Lock Wall Fitting NSF

(Part #GW9530)

45º Hose Connector

(Part #K12078)

Snap-Lock Wall Fitting

45° Hose
Connector

Male/Female
Hose Section

Thread Snap-Lock
into Dedicated
Suction Line
in Pool Wall

Figure 10

Top of Skimmer

Automatic
Regulator
Valve

Threaded
Compression
Adapter
(or 2'' Hose Cone)

Valve
Cap

Automatic
Regulator Valve

Threaded
Adapter

Screw (or press) into
bottom of Skimmer

2'' Hose Cone
(not included)

Attach Hose This End

Figure 11

Figure 12

10

V. Troubleshooting

Because of the individual characteristics of your pool, some additional adjustments may be required to
get the best performance from your Kreepy Krauly.

If there seems to be a problem, check these common causes of cleaner problems. If you still need help,
call your pool professional or call our toll-free

Customer Helpline at 1-800-443-5711.

— Is bottom main drain closed?

Close drain

— Is filter clean?

Clean filter

— Is pump strainer basket clean?

Clean basket

— Is debris blocking the bottom

of Kreepy Krauly?

Remove debris

— Are there any leaks in the hose?

Replace leaky section

— Is automatic regulator valve

free of debris?

Clean valve

If Kreepy Krauly is not moving or not pulsating.

• Check to ensure that the main drain and

all

suction lines are closed,

except

for the suction

line to which Kreepy Krauly is attached.

• Check for debris in the filter or pump basket.
• Check for debris in Kreepy Krauly’s flapper. Debris may prevent flapper movement or

restrict flow. See page 13 for instructions.

• Pool pump and filter system may be too small (incapable of providing 25 gallons per minute

water flow). Consult your pool professional.

If Kreepy Krauly stays in one end of the pool.

• Check the return line water flow and redirect as necessary with an eyeball diverter.

Refer to page 9.

• Check that hose is long enough to reach to end of pool. Refer to page 8.
• Check that Kreepy Krauly has proper hose balance. Refer to page 8.

If Kreepy Krauly stays on the main drain.

• Check to ensure that main drain is closed. A pool professional may need to assist you.
• Check to ensure that a main drain grate is installed.
• If main drain is not flush with the pool floor, consult your pool professional.

If Kreepy Krauly slows or stops and air bubbles enter the pool at the return line.

Find and correct the air leak that is causing the pump to lose its prime:

• Check the hose to ensure there are no leaks.
• Check the vacuum connection. It should be submerged so no air enters the system.
• Check the pump basket lid for looseness, cracks, and worn or missing O-rings. If you need

assistance, contact your pool professional.

Содержание Kreepy krauly

Страница 1: ......

Страница 2: ...l have a question call our Customer Helpline at 1 800 443 5711 Please have your Kreepy Krauly serial number ready when you call Warranty Note Cleaners purchased in the United States of America from en...

Страница 3: ...ht locations Kreepy Krauly s hose is specially designed to ensure optimum performance from Kreepy Krauly Should replacement be required insist on genuine Kreepy Krauly hose VIII Customer Service Your...

Страница 4: ...rap into the locking clip attached to the swivel head See Figure 4 Step 4 Attach The Dive Float Restrictor Snap the dive float restrictor into the lower U shaped brace between the dive floats Make sur...

Страница 5: ...line water flow and re direct as necessary with an eyeball diverter Refer to page 9 Check Kreepy Krauly s hose to ensure it has not become bent or kinked It only takes one bent or kinked hose section...

Страница 6: ...or Valve Threaded Compression Adapter or 2 Hose Cone Attach Hose This End Top of Skimmer Figure 9 11 If Kreepy Krauly is moving too fast In most pools the automatic regulator valve supplies Kreepy Kra...

Страница 7: ...Connector Male Female Hose Section Thread Snap Lock into Dedicated Suction Line in Pool Wall Figure 10 Top of Skimmer Automatic Regulator Valve Threaded Compression Adapter or 2 Hose Cone Valve Cap Au...

Страница 8: ...ce 3 Hose Too Heavy Figure 13 Return Line Water Flow IMPORTANT The water flow from your return line can push Kreepy Krauly s hose and affect its performance It may cause Kreepy Krauly to steer away fr...

Отзывы: