STANDARD LIMITED WARRANTY

Pentair Hydromatic

®

 warrants its products against defects in material and workmanship for a period of 12 months 

from the date of shipment from Pentair Hydromatic or 18 months from the manufacturing date, whichever  

occurs first – provided that such products are used in compliance with the requirements of the Pentair Hydromatic  

catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive-free,  

noncorrosive liquids. 

during the warranty period and subject to the conditions set forth, Pentair Hydromatic, at its discretion, will repair 

or replace to the original user, the parts that prove defective in materials and workmanship. Pentair Hydromatic 

reserves the right to change or improve its products or any portions thereof without being obligated to provide such 

a change or improvement for prior sold and/or shipped units.

Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of start up 

through the Pentair Hydromatic website: http://forms.pentairliterature.com/startupform/startupform.asp?type=h.  

Warranty is effective only if Pentair Hydromatic authorized control panels are used. All seal fail and heat sensing 

devices must be hooked up, functional and monitored or this warranty will be void. Pentair Hydromatic will cover 

only the lower seal and labor thereof for all dual seal pumps. under no circumstance will Pentair Hydromatic be 

responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight 

expenses to and from the factory or an authorized Pentair Hydromatic service facility.
This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or 

maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident 

or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that 

are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is 

moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and 

manufactured; (g) to any unit that has been repaired or altered by anyone other than Pentair Hydromatic or an 

authorized Pentair Hydromatic service provider; (h) to any unit that has been repaired using non factory specified/

oEM parts.

Warranty Exclusions: PEnTAiR HYdRoMATiC MAKES no EXPRESS oR iMPLiEd WARRAnTiES THAT EXTEnd 

bEYond THE dESCRiPTion on THE FACE HEREoF. PEnTAiR  HYdRoMATiC SPECiFiCALLY diSCLAiMS THE 

iMPLiEd WARRAnTiES oF MERCHAnTAbiLiTY And FiTnESS FoR AnY PARTiCuLAR PuRPoSE.

Liability Limitation: in no EVEnT SHALL PEnTAiR  HYdRoMATiC bE LiAbLE oR RESPonSibLE FoR 

 

ConSEQuEnTiAL, inCidEnTAL oR SPECiAL dAMAGES RESuLTinG FRoM oR RELATEd in AnY MAnnER To  

AnY  PEnTAiR  HYdRoMATiC PRoduCT oR PARTS THEREoF. PERSonAL inJuRY And/oR PRoPERTY dAMAGE  

MAY RESuLT FRoM iMPRoPER inSTALLATion. PEnTAiR  HYdRoMATiC diSCLAiMS ALL LiAbiLiTY, inCLudinG 

LiAbiLiTY undER THiS WARRAnTY, FoR iMPRoPER inSTALLATion. PEnTAiR  HYdRoMATiC RECoMMEndS 

inSTALLATion bY PRoFESSionALS.

Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or 

consequential damages and therefore such limitations may not apply to you. no warranties or representations at any 

time made by any representatives of Pentair Hydromatic shall vary or expand the provision hereof.

Содержание HYDROMATIC H3H

Страница 1: ...to the owner of the equip ment or to the responsible party who maintains the system MODELS H3H H4H S4M S4P S4HRC and S4MRC SUBMERSIBLE SOLIDS HANDLING PUMPS INSTALLATION AND SERVICE MANUAL For use with product built with GE motor Item E 03 467 Part 5625 467 1 2013 Pentair Pump Group Inc 11 06 13 ...

Страница 2: ... seal should be checked immedi ate ly after failure is indicated The sensing unit is recommended on all installations as good insurance against motor failure Pump The submersible pumps in this manual are supplied for 1 and 3 phase and for 200 230 460 or 575 volts Power cable is supplied with the green wire for ground Be sure green wire is connected to a good ground such as water pipe or ground sta...

Страница 3: ...lled on each pump A gate or plug valve in each pump discharge line is also recommended This valve should be installed on the discharge side of the check valve so the line pressure can be cut off if necessary to service the check valve Single pump systems are sometimes installed without a check valve where it is desirable to self drain the dis charge line to prevent freezing This can be done only w...

Страница 4: ...th H O Aswitches to Auto position and allow water to rise in sump until one pump starts Allow pump to op er ate until the level drops to turn off point 5 Allow sump level to rise to start other pump Notice run lights on panel Pumps should alternate on each successive cycle of op er a tion 6 Turn both H O A switches to Off position and allow sump to fill to the override control level 7 Turn both sw...

Страница 5: ...e damage to stator and bear ings 8 Check top bearing If clean and does not turn rough bearings can be reused and it is not necessary to com plete ly dismantle pump to change bearings If bearings are damagedwithdirtorheat they must be replaced Remember to reinstall the upper bearing load spring 9 Replace stator housing onto seal chamber and bolt in place BE SURE SEAL FAILURE WIRE IS CONNECTED BEFOR...

Страница 6: ... from taper shaft Remove impeller IMPORTANT The impeller is designed to be self tightening when running so impeller may be difficult to break loose If this is the case use plastic or rubber hammer on im pel ler tip to free Remove impeller 6 Remove lower seal spring and pry out seal with screwdriver 7 To remove seal housing take out socket head bolts and using bolts in back of holes pry plates loos...

Страница 7: ...n 4 Discharge head may be too high Check total head with gauge when pump is operating Total head is dis charge gauge pressure converted to feet plus vertical height from water level in sump to center line of pres sure gauge in discharge line Gaugeshouldbeinstalled on pump side of all valves Multiply gauge pressure in pounds by 2 31 to get head in feet 5 If pump has been in service for some time an...

Страница 8: ...0 1750 RPM R 1 146742031 Stator 15 hp 200 3 60 1750 RPM R 1 146746031 Stator 15 hp 575 3 60 1750 RPM R 1 146720031 Stator 7 5 hp 230 1 60 1750 RPM R 1 14 070690002 Motor Housing 1 15 070740003 Retaining Plate 1 16 060000215 Wire w terminal 1 17 002380031 Hex Hd Bolt 8 18 009200011 Upper Seal SC 1 19 081000005 Lower Seal Ceramic Std S 1 081000025 Lower Seal Carbide Opt C 1 20 009750031 Snap Ring 1 ...

Страница 9: ...0002 Motor Housing 1 14 060000215 Wire w terminal 1 15 070740003 Retaining Plate 1 16 00065031l Lower Bearing 1 17 001500071 O Ring SC 1 18 009200011 Upper Seal SC 1 19 081000005 Lower Seal Ceramic Std S 1 081000025 Lower Seal Carbide Opt C 1 20 009750031 Snap Ring 1 21 080230001 Washer 1 22 070770023 Wear Ring 1 23 005680021 Bolt 1 24 001500291 O Ring SC 1 25 070720002 Seal Housing 1 26 151460002...

Страница 10: ...0 hp 230 460V 3f 1 RTF Stator 10 hp 200V 3f 1 RTF Stator 10 hp 575V 3f 1 RTF Stator 15 hp 200 3 60 1750 RPM 1 RTF Stator 15 hp 230 460 3 60 1750 RPM 1 10 070690002 Motor Housing 1 11 001500071 O Ring SC 1 12 007360061 Spacer Ring 3 5 hp 1150 RPM 1 007360061 Spacer Ring 5 7 1 2 hp 1750 RPM 1 None Spacer Ring 7 5 hp 1f 10 15 hp 1750 RPM 1 13 060000211 Wire w Terminal 1 14 08565A027 Lower Bearing 1 1...

Страница 11: ...or 15 hp 575 3 60 1750 RPM 1 146720031 Stator 7 5 hp 230 1 60 1750 RPM 1 14 070690002 Motor Housing 1 15 070740003 Retaining Plate 1 16 060000215 Wire w terminal 1 17 001500471 O Ring SC 1 18 009200011 Upper Seal SC 1 19 081000005 Lower Seal Ceramic Std S 1 081000025 Lower Seal Carbide Opt C 1 20 009750031 Snap Ring 1 21 080230001 Washer 1 22 070770023 Wear Ring 1 23 005680021 Bolt 1 24 001500291 ...

Страница 12: ... Hd Cap Screw 4 15 010060011 Wire Connector 230 460V 9 010060011 Wire Connector 200 575V 3 16 002820011 Wire Connector 3 17 060000211 Wire w Terminal 1 18 081000005 Seal Lower Ceramic Std S 1 081000025 Seal Lower Carbide Opt C 1 19 009200011 Seal Upper SC 1 20 009750031 Snap Ring 1 21 080230011 Washer 1 22 029210041 Screw Flat Head Machine 1 23 083460011 Key 1 24 082130002 Impeller 6 Dia 1 0821300...

Страница 13: ... 1150 RPM 1 RTF Stator 5 hp 575 3 60 1150 RPM 1 RTF Stator 5 hp 230 1 60 1750 RPM 1 RTF Stator 7 5 hp 200 3 60 1750 RPM 1 RTF Stator 7 5 hp 230 460 3 60 1750 RPM 1 RTF Stator 7 5 hp 575 3 60 1750 RPM 1 RTF Stator 10 hp 230 400 1750 RPM 1 RTF Stator 15 hp 200 3 60 1750 RPM 1 RTF Stator 15 hp 230 460 3 60 1750 RPM 1 23 005680021 Bolt 1 24 001500291 O Ring SC 1 25 070720002 Seal Housing 1 26 07081000...

Страница 14: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 15: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 16: ...o and from the factory or an authorized Pentair Hydromatic service facility This limited warranty will not apply a to defects or malfunctions resulting from failure to properly install operate or maintain the unit in accordance with the printed instructions provided b to failures resulting from abuse accident or negligence c to normal maintenance services and parts used in connection with such ser...