Pentair GREEN LEAF Скачать руководство пользователя страница 2

2

Contents

1. DesCRIPtIon ..................................................3
2. MoUntInG AnD InstALLAtIon ......................4

Mounting the thermostat ...............................4

3.UsInG tHe tHeRMostAt .................................9

the Display.....................................................9

Display in manual on/off programme ...................9
Display in timer programme .............................. 10

the manual on/off programme ....................11
the timer programme ..................................12

4. settInG tHe CLoCK .....................................14
5. PRoGRAMMInG tHe tIMeR PRoGRAMMe ....15
6. InstALLeR MenU .........................................17
7. tRoUBLesHootInG ......................................21
8. teCHnICAL sPeCIFICAtIon ..........................22

Содержание GREEN LEAF

Страница 1: ...THERMAL MANAGEMENT SOLUTIONS EN RaychemGreenLeaf IM EU0209 R1 GREEN LEAF PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING Installation Instructions...

Страница 2: ...SING THE THERMOSTAT 9 The Display 9 Display in manual on off programme 9 Display in timer programme 10 The manual on off programme 11 The timer programme 12 4 SETTING THE CLOCK 14 5 PROGRAMMING THE TI...

Страница 3: ...t possible comfort and the lowest possible energy usage The Thermostat can work in 3 different temperature sensing modes Floor Sensing mode Room Sensing mode Room Sensing mode with floor temperature l...

Страница 4: ...s above the floor protected from direct sunlight and draughts All electrical conduits passing into the wall box that contain cables must also be sealed to protect the thermostat against draughts e g w...

Страница 5: ...all the way to the end covering the end of the sensor for easy replacement and to avoid possible signal disturbance on the sensor For best control performance position the floor sensor between two hea...

Страница 6: ...to the electrical diagram If you connect heating cables exceeding 13A for constant wattage or 10A for self regulating cables you must use a contactor with an integrated suppression device For the eart...

Страница 7: ...onnection via contactor e Do not use contactor without 10K L N Power supply 230 VAC Power supply 230 VAC e heating circuit 0A for self regulating cables L N NTC Floor Sensor Power supply heating cable...

Страница 8: ...the Green Leaf thermostat working in floor sensor mode Be aware that the floor sensor must be installed and activated for any installation with T2QuickNet T2Red Self regulating heating cables have an...

Страница 9: ...al on off programme The following icons are visible in the Manual ON OFF Active sensor display Floor sensing mode Room Sensing mode Room Sensing mode with Floor temperature limiter Heating display The...

Страница 10: ...e on the display Room sensing with floor temperature limiter mode Room temperature on the display Remark When pushing on the or button the set point temperature appears on the display blinking for 5 s...

Страница 11: ...display The 4 events are displayed with the symbols Event 1 Event 2 Event 3 Event 4 The manual on off programme When switching on the thermostat for the first time pressing on the Green Leaf button fo...

Страница 12: ...h 4 events per day Different temperatures can be maintained for each event of the day The days can be programmed independently or per cluster of days The default Timer Programme is shown on the graph...

Страница 13: ...s on the button to set the clock and day of the week Press on the button for 3 seconds to program the timer programme see page 14 for more details Press on the button for 5 seconds to enter the Instal...

Страница 14: ...e the hours Press on the button to validate Press the or the to change the minutes Press on the button to validate Press the or the to change the day of the week Press on the button to validate Remark...

Страница 15: ...for 3 seconds to program the Timer Programme Press the or the to choose the day or the sequence of days you want to program Press on the button to validate Day Sequences are MON TUE WED THU FRI SAT SU...

Страница 16: ...ss the or the to change the set point temperature for Event 1 Press on the clock button to validate For Event 2 3 and 4 Repeat the actions for event 1 for the Events 2 3 and 4 Press on the button at a...

Страница 17: ...on Floor sensing mode Room sensing mode Room sensing mode with floor temperature limiter Floor Sensing mode 2 12 vs 24 hours display 12 24 24 3 Motion sensor When getting close to the thermostat 5cm r...

Страница 18: ...with floor temperature limiter OF 5 C OF OF 7 Maximum temperature set point for the Floor Sensor Floor sensing mode Minimum temperature set point floor sensor installer menu 6 5 C 35 C Room sensing mo...

Страница 19: ...nsor Floor sensing mode OF Room sensing mode Minimum temperature set point room sensor installer menu 8 5 C 40 C Room sensing mode with floor temperature limiter Minimum temperature set point room sen...

Страница 20: ...e on the surface Tsurface Read the floor sensor temperature Tsensor on the thermostat and adjust the OFFSET accordingly to the formula Tsensor Tsurface OFFSET Tsensor Tsurface Room sensor calibration...

Страница 21: ...mode The floor sensor can be replaced by a new one In the event of malfunction of the room sensor the entire thermostat must be replaced The floor sensor has got the following temperature resistance...

Страница 22: ...mperature range floor sensor 5 35 C Temperature range room sensor 5 40 C Switching hysteresis 1 C Factory settings adjustable between 0 5 2 0 C Control modes Floor sensing Room sensing Room sensing wi...

Страница 23: ...23...

Страница 24: ...trademarks and logos are owned by Pentair or its global affiliates Pentair reserves the right to change specifications without prior notice 2013 Pentair European headquarters Tel 32 16 21 35 02 Fax 32...