PAGE 1 of 24
©COPYRIGHT Goyen Controls Co. Pty. Ltd.
DESCRIPTION
The Integrato Sequencer (IS & ISP) features integrated controls
intended for use with larger reverse pulse jet filter cleaning
systems. The IS & ISP have been designed to operate across a
wide range of environmental conditions. It is suitable for use with
all types of filters, including bags, cartridges, sintered metal or
ceramic filters.
The IS sequencer operates in continuous mode, whereas the ISP
has a built-in differential pressure sensor, allowing this sequencer
to be demand driven.
IS & ISP may be ordered as the sequencer only or in an enclosure
(polycarbonate).
FEATURES
•
Low temperature operation −40°C (−40°F)
•
Automatic valve detection.
•
Voltage-free coil error output and a visual indication on the
display showing which pilot valve output has an error, enabling
quick fault finding and debugging.
•
Controls up to 40 pilot valves. Each AC output can have 10 pilot
valves connected in parallel, enabling up to 400 pilot valves to be
supported. Each DC output can have 3 pilot valves connected in
parallel between −20°C to 60°C (−4°F to 140°F), enabling up to
120 pilot valves to be supported and 2 pilot valves connected in
parallel between −40°C to 60°C (−40°F to 140°F), enabling up to
80 pilot valves to be supported.
•
Conforms to the requirements of UL, CE, FCC and RCM.
TECHNICAL CHARACTERISTICS & PERFORMANCE
dP Support
0 to 4.5 kPa
Input Voltage
AC: 100/240 V @ 50/60 Hz
Output Voltage
AC: 100/240 V @ 50/60 Hz (same as input)
DC: 24 V
Maximum Input Power
AC IN, AC OUT Model: 225 W
AC IN, DC OUT Model: 65 W
Discrete Solenoid Outputs
12, 20 or 40 outputs
Enclosure
Polycarbonate or no enclosure
Protection Rating (Large
Enclosure)
Polycarbonate: IP 66/67 & NEMA 1, 3, 3S,
4, 4X, 6, 6P & 12
Protection Rating (Small
Enclosure)
Polycarbonate: IP65 & NEMA 1, 4, 4X, 12
& 13
Operating Temperature
−
40
°
C to 60
°
C (
−
40
°
F to 140
°
F)
ON & OFF Time
ON: 30 ms to 1000 ms, OFF: 1 s to 1000 s
Inputs
Voltage Free: Fan Stop, Low Header Alarm
Outputs
Voltage Free: Coil Error.
Analogue Output: 4–20 mA dP signal on
the ISP
PRODUCT INSTALLATION INSTRUCTIONS
GOYEN IS/ISP SERIES CONTROLLER
DEINE-012
ISSUE: 4
DATE: 04.05.2016
CIRCUIT BOARD LAYOUT
ISP12
ISP40
1
AC Input Voltage: Electrical connection to the board. Active, Earth
and Neutral connections. Max. cable size 14–26 AWG.
2
ON:OFF Power Switch: Switch power the board ON and OFF.
3
Fuse (Over Current Protection): Replacement fuse T2.5 A 250 V
(slow blow).
4
Outputs Common Terminal: This is the common terminal for all
the 12 solenoid outputs. Max. cable size 12–22 AWG.
5
Discrete Solenoid Output Terminals: Connect each solenoid wire
to a separate output terminal. Max. cable size 12–22 AWG.
6
Coil Alarm Output (Voltage Free): This output triggers when the
coil fails to pulse correctly. It may indicate a fault with the coil or
wiring to that coil. Max cable size 14–26 AWG.
7
4–20 mA dP Output: This output mirrors the output of the built in
dP sensor in the form of a 4–20 mA signal. (ISP only)
8
Low Header Alarm Input (Voltage Free): This input allows for the
connection of a sensor to monitor the header tank pressure. In
the event the pressure drops below the preset level, the pulsing
cycle is paused. Max. cable size 14–26 AWG.
IS/ISP SERIES
INTEGRATO SEQUENCER
1
2
3
4
5
7
6
8
9
10
11
12 13
14
15
5
4
16
3
1
2
4
5
6
7
8
9
10
11
12
13
14
15
16
ENGLISH