![Pentair GLOBRITE Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/pentair/globrite/globrite_installation-and-user-manual_1524660011.webp)
GLOBRITE™ White LED Light Installation and User’s Guide
GLOBRITE™ White LED Light Installation and User’s Guide
7
Installing GloBrite
™
Light Niche in a Fiberglass Pool
To install the GloBrite
™
white light niche in a fiberglass pool:
1. Drill or punch a 5 cm (2 in) hole in the desired location for the GloBrite light
niche.
2. Place the sealing gasket on the niche as shown below.
3. Insert the niche through the 5 cm (2 in) hole in the pool wall.
4. Install the PVC washer to the back of the niche.
5. Install the plastic nut onto the back of the niche. Hand tighten the nut to
secure the niche in place.
6. Glue the 2.5 cm (1 in) conduit into back of niche.
GloBrite White Light Niche (Fiberglass pool) Installation Diagram
2.54 cm (1 in) Conduit
Nut
Niche
Pool wall
Sealing gasket
PVC washer
Figure 2, Gunite Light Installation Diagram
(20.3 cm (8 in)
1.22 m (48 in) minimum
USA: 10.2 cm
(4 in) to top of
lens
Color Ring and Gunite Cover
To
12 VAC
Transformer
Niche Sleeve
(cut flush to wall
before plastering)
Plaster Finish
10.2 cm (4 in)
Ridgid
2.54 cm (1 in)
Conduit
Niche Sleeve: 5.08 cm (2 in) PVC Pipe
For Gunite Niche Only
35.1 cm (15 in)
Canada: 600 mm max.
to centerline of the Lens