Installer Manual Fleck 5812 - XTR - Description
Ref. MKT-IM-019 / E - 14.10.2019
15 / 132
Electrical
Transformer input voltage ............................................... 100 to 240 VAC
Input supply frequency ..................................................... 50 to 60 Hz
Transformer output voltage ............................................. 12 VDC
Motor input voltage........................................................... 12 VDC
Controller input voltage.................................................... 12 VDC
Controller max. power consumption ............................... 6 W
Protection rating............................................................... IP 22
Power supply .................................................................... 100 to 240 VAC, 50/60 Hz, 0.8 A, Class II
Transient overvoltages ..................................................... Within the limits of category II
Pollution Degree............................................................... 3
Temporary overvoltages must be limited in duration and in frequency.
Environmental conditions
•
Indoor use only;
•
temperature from 0°C to 52°C;
•
maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative
humidity at 40°C;
•
mains supply voltage fluctuations up to ±10% of the nominal voltage.
3.1.1. Performance flow rate characteristics
The graph shows the pressure drop created by the valve itself at different flow rates. It allows to
predetermine the maximum flow rate going through the valve depending on the system settings (inlet
pressure etc). It also allows to determine the valve pressure drop at a given flow rate, and therefore
to evaluate the system pressure drop vs flow rate.
Содержание FLECK 5812 XTR
Страница 1: ...INSTALLER MANUAL WATER PURIFICATION FLECK 5812 XTR...
Страница 18: ...Installer Manual Fleck 5812 XTR Description 18 132 Ref MKT IM 019 E 14 10 2019 3 2 2 Base 4...
Страница 108: ...Installer Manual Fleck 5812 XTR Maintenance 108 132 Ref MKT IM 019 E 14 10 2019...
Страница 110: ...Installer Manual Fleck 5812 XTR Maintenance 110 132 Ref MKT IM 019 E 14 10 2019...
Страница 124: ...Installer Manual Fleck 5812 XTR Spare parts 124 132 Ref MKT IM 019 E 14 10 2019 11 3 Valve parts list...
Страница 132: ...www pentairaquaeurope com...