8.
Operation
8.1.
Display during operation
8.2.
Display during regeneration
During regeneration, the regeneration cycle wheel shows the regeneration step the valve is advancing
to, or has reached (green), and the time remaining in that step (
1
). Once all regeneration steps are
complete the valve returns to treatment position and resumes normal operation. The time remaining
in each regeneration step will be displayed on the home screen in hours and minutes.
Pressing the
button during a regeneration cycle immediately advances the valve to the next cycle
step position and resumes normal step timing. The
button is only available when the valve is in
position and the motor has stopped.
Pressing
will cancel regeneration and the valve will return to treatment position.
8.3.
Controller operation during programming
The controller can only be programmed with the valve in treatment. While being programmed the
controller continues to operate normally, monitoring water usage and keeping all displays up to date.
Controller programming is stored in memory permanently until reset.
Water treatment
wed
12:01 am
4.5
m
3
treatment
tank refill
rapid rinse
backwash
draw
Regeneration
48 m
34 s
treatment
tank refill
rapid rinse
backwash
draw
Содержание FLECK 5812 XTR
Страница 1: ...INSTALLER MANUAL WATER PURIFICATION FLECK 5812 XTR...
Страница 18: ...Installer Manual Fleck 5812 XTR Description 18 132 Ref MKT IM 019 E 14 10 2019 3 2 2 Base 4...
Страница 108: ...Installer Manual Fleck 5812 XTR Maintenance 108 132 Ref MKT IM 019 E 14 10 2019...
Страница 110: ...Installer Manual Fleck 5812 XTR Maintenance 110 132 Ref MKT IM 019 E 14 10 2019...
Страница 124: ...Installer Manual Fleck 5812 XTR Spare parts 124 132 Ref MKT IM 019 E 14 10 2019 11 3 Valve parts list...
Страница 132: ...www pentairaquaeurope com...