![Pentair FLECK 5812 XTR Скачать руководство пользователя страница 113](http://html1.mh-extra.com/html/pentair/fleck-5812-xtr/fleck-5812-xtr_installer-manual_1525053113.webp)
Installer Manual Fleck 5812 - XTR - Maintenance
Ref. MKT-IM-019 / E - 14.10.2019
113 / 132
9.4.7. Optical sensor replacement
No.
Operation
A
Remove the controller, see 9.4.2. Controller replacement, page 106.
B
Release the optical sensor support (
1
) by pushing it back and up as shown.
C
Release the optical sensor (
3
) from its support (
1
) by pressing the clips (
2
).
D
Disconnect the wire from the motor to the optical sensor (
4
).
E
Change the optical sensor (
3
).
F
Reverse above procedure steps to rebuild.