MASTER SETTINGS PROGRAMMING
continued
Meter Screen
From the main Master Settings screen (Figure 17) press the
meter
button to display the Meter screen.
Figure 24 Meter Screen
• meter type
: Contains settings for the type of meter
installed with the system. The 5810/5812 valve uses an
internal 1.25" turbine meter.
• generic
: A generic option is available if the installed
meter does not match any other selection. Requires
setting the number of pulses per volume to ensure proper
metering.
• plumbing leak detect
: When active, triggers an alarm
when continuous flow of .5 GPM or 1 LPM is detected by
the flow meter over a 24 hour period.
Settings Review
From the main Master Settings screen (Figure 17) press the
settings review button to display the Settings Review screens,
which display a read-only summary of all programmed settings
in the control.
Figure 25 Format Settings Review Screen
Use the navigation arrows at the top of the screen to scroll
through the parameters currently set in the control. The
Settings Review screens are formatted similarly to the
corresponding screen where each parameter was set. Press
to return to Master Settings.
Remote Regen Screen
From the secondary Master Settings screen (Figure 18) press
the
remote regen
button to display the Remote Regen screen.
Figure 26 Remote Regen Screen
• remote regen duration:
Contains settings for triggering a
regeneration via a remote input. Select a value in seconds
that the remote switch must be closed in order to trigger
the regeneration.
Connect a remote switch (such as a differential pressure
switch) to the remote start input terminals on the back of the
XTR2 control board. See "WIRING DIAGRAM" on page 27.
When the remote switch remains closed for the number of
seconds specified in the Remote Regen screen, a regeneration
will be triggered regardless of volume, capacity, or time
remaining until the next scheduled regeneration.
FLECK
5810 & 5812 XTR2 Service Manual • 13