From the main Master Settings screen (Figure 13) press the
meter
button to display the Meter screen.
Figure 17 Meter Screen
• meter type
: Contains settings for the type of meter
installed with the system. The 5810/5812 valve uses an
internal 1.25" turbine meter.
• generic
: A generic option is available if the installed
meter does not match any other selection. Requires
setting the number of pulses per volume to ensure proper
metering.
• emergency regen
: When on, the emergency regen feature
causes a regen to occur immediately when 105% or
greater of the capacity (e.g., volume plus reserve)
is used.
Continuous Flow Detect Screen
From the Meter screen (Figure 19) press to display the
Continuous Flow Detect screen.
Figure 18 Continuous Flow Detect Screen
• continuous flow detect:
When active, triggers an alarm
when continuous flow of 0.5 GPM or 1 LPM is detected by
the flow meter over an 8-hour period.
• Press the
button when finished to return to the Home
screen.
Meter Screen
Settings Review
From the main Master Settings screen (Figure 13) press the
settings review button to display the Settings Review screens,
which display a read-only summary of all programmed settings
in the control. Use the navigation arrows at the top of the
screen to scroll through the parameters currently set in the
control. The Settings Review screens are formatted similarly
to the corresponding screen where each parameter was set.
Press to return to Master Settings.
Non-Factory Settings
After all parameters in Master Programming have been set,
these settings can be saved to a custom profile by pressing
on the main Master Settings screen (Figure 13). After pressing
, the Non-Factory Settings screen appears.
Figure 19 Non-Factory Settings Screen
Press to save all programmed Master Settings parameters
to non-factory settings. At any point, the control can be reset
to these saved custom settings. By performing a custom reset,
any setting that is subsequently programmed without saving to
non-factory settings will be reset to the previously saved non-
factory settings in the control.
MASTER SETTINGS PROGRAMMING
(continued)
12 •
FLECK
5800/5810/5812 XTRI Service Manual
Содержание FLECK 5800
Страница 1: ...FLECK 5800 5810 5812 XTRI CONNECTED XTR2 SERVICE MANUAL pentair com...
Страница 36: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Upflow 36 FLECK 5800 5810 5812 XTRI Service Manual...
Страница 37: ...WATER CONDITIONER FLOW DIAGRAMS 5810 Downflow FLECK 5800 5810 5812 XTRI Service Manual 37...
Страница 44: ...INJECTOR FLOW DATA TR18755 REV B 44 FLECK 5800 5810 5812 XTRI Service Manual...