SERVICE INSTRUCTIONS

A.  TO REMOVE TIME BRINE VALVE, INJECTORS, AND 

SCREEN

1.  Unplug electrical cord from outlet.

2.  Turn off water supply to conditioner:

a.  If the conditioner installation has a “three valve” 

bypass system, first open the valve in the bypass 

line, then close the valves at the conditioner inlet 
and outlet.

b.  If the conditioner has an integral bypass valve, put 

it in the bypass position.

c.  If there is only a shut-off valve near the conditioner 

inlet, close it.

3.  Relieve water pressure in the conditioner by putting the 

control in the backwash position momentarily. Return 
the control to the service position.

4.  Disconnect brine tube and drain line connections at the 

injector body.

5.  Remove the two injector body mounting screws. The 

injector and brine module can now be removed from 
the control valve. Remove and discard valve body 
O-rings.

6.  To replace brine valve:

a.  Pull brine valve from injector body, also remove and 

discard O-ring at bottom of brine valve hole.

b.  Apply silicone lubricant to new O-ring and reinstall 

at bottom of brine valve hole.

c.  Apply silicone lubricant to O-ring on new valve 

assembly and press into brine valve hole, shoulder 

on bushing should be flush with injector body.

7.  To replace injectors and screen:

a.  Remove injector cap and screen, discard O-ring. 

Unscrew injector nozzle and throat from injector 
body.

b.  Screw in new injector throat and nozzle. Be sure 

they are seated tightly. Install a new screen.

c.  Apply silicone lubricant to new O-ring and install 

around oval extension on injector cap.

8.  Apply silicone lubricant to three new O-rings and install 

over three bosses on injector body.

9.  Insert screws with washers through injector cap and 

injector. Place this assembly through hole in timer 
housing and into mating holes in the valve body. 
Tighten screws. Be sure to reinstall brass spacers with 
injector on Model 4600 valve.

10.  Reconnect brine tube and drain line.

11.  Return bypass or inlet valving to normal service 

position. Water pressure should now be applied to the 
conditioner, and any bypass line shut off.

12.  Check for leaks at all seal areas. Check drain seal with 

the control in the backwash position.

13.  Plug electrical cord into outlet.

14.  Set time of day and cycle the control valve manually to 

ensure proper function. Make sure the control valve is 
returned to the service position.

15.  Make sure there is enough brine in the brine tank.

16.  Rotate program wheel counterclockwise until it stops at 

regeneration position.

17.  Start regeneration cycle manually if water is hard.

B.  TO REPLACE TIMER

1.  Unplug electrical cord from outlet.

2.  Turn off water supply to conditioner:

a.  If the conditioner installation has a “three valve” 

bypass system, first open the valve in the bypass 

line, then close the valves at the conditioner inlet 
and outlet.

b.  If the conditioner has an integral bypass valve, put 

it in the bypass position.

c.  If there is only a shut-off valve near the conditioner 

inlet, close it.

3.  Relieve water pressure in the conditioner by putting the 

control in the backwash position momentarily. Return 
the control to the service position.

4.  Remove the control valve back cover.

5.  Remove screw and washer at drive yoke. Remove 

timer mounting screws. The entire timer assembly will 
now lift off easily.

6.  Put new timer on top of valve. Be sure drive pin on 

main gear engages slot in drive yoke (rotate control 
knob if necessary).

7.  Replace timer mounting screws. Replace screw and 

washer at drive yoke.

8.  Return bypass or inlet valving to normal service 

position. Water pressure should now be applied to the 
conditioner, and any bypass line shut off.

9.  Plug electrical cord into outlet.

10.  Set time of day, program wheel, and salt usage. Cycle 

the control valve manually to ensure proper function. 
Make sure the control valve is returned to the service 
position.

11.  Replace the control valve back cover. Be sure 

grommet at cable hole is in place.

12.  Make sure there is enough brine in the brine tank.

13.  Rotate program wheel counterclockwise until it stops at 

regeneration position.

14.  Start regeneration cycle manually if water is hard.

 Fleck 4650 AP10 • 7

Содержание Fleck 4650

Страница 1: ...of Day Arrow BR61501 4650 Rev A Figure 1 1 Manually index the softener control into the service position and let water flow into the resin tank When the water flow stops open a softened water tap unt...

Страница 2: ...24 Hour Gear Assembly Silver 13 1 13011 Cycle Actuator Gear 14 1 14177 Knob Manual Regeneration 15 4 13300 Ball 1 4 Dia 16 2 13311 Spring Detent Skipper Wheel 17 1 14207 Knob Label Silver 18 1 14176 V...

Страница 3: ...021 560CD HW 22 1 13163 Injector Body 23 1 10225 xx Injector Nozzle Hot Water 1 10913 xx Injector Nozzle Cold Water 24 1 10226 xx Injector Throat Specify Size Hot Water 1 10914 xx Injector Throat Spec...

Страница 4: ...Plug Bypass 4 1 11978 Side Cover 5 1 13604 03 Label 6 8 15727 Screw 7 1 11986 Side Cover 8 1 11979 Lever Bypass 9 1 11989 Screw Hex Head 1 4 14 10 1 60040SS Bypass Valve 5600 3 4 NPT Blk Grip Lever SS...

Страница 5: ...hole in the piston over the top edge of the piston and out the drain line 3 Backwash Position 10 Minutes Hard water enters the unit at the valve inlet flows around the lower piston groove and lower p...

Страница 6: ...k passage around the upper piston groove and out the drain line 7 Settling Rinse Position 5 Minutes Hard water enters the unit at the valve inlet flows around the lower piston groove down thru the top...

Страница 7: ...normal service position Water pressure should now be applied to the conditioner and any bypass line shut off 12 Check for leaks at all seal areas Check drain seal with the control in the backwash posi...

Страница 8: ...lace timer mounting screws Replace screw and washer at drive yoke 11 Return bypass or inlet valving to normal service position Water pressure should now be applied to the conditioner and any bypass li...

Страница 9: ...nt work done on plumbing system Remove piston and clean control Loss of resin through drain line Air in water system Ensure that well system has proper air eliminator control Check for dry well condit...

Страница 10: ...Cold Water 60032 001 Brine Valve Hot Water 60514 Brine Cam 3 18 60514 01 Brine Cam 6 36 60514 02 Brine Cam Minutes 60510 Coupling with Clip and Screws 60040 Bypass Brass 3 4 NPT Cold Water 60041 Bypas...