Item No. 

QTY 

Part No. 

Description  

 

1 ................1 ....... 40614 ................Bypass Body, 3/4"

 

 

 ........ 40634 ................Bypass Body, 1", SS

 

2 ................1 ....... 14105 ................Seal, Bypass, 560CD

 

3 ................1 ....... 11972 ................Plug, Bypass

 

4 ................1 ....... 11978 ................Side Cover

 

5 ................1 ....... 13604-03 ...........Label

 

6 ................8 ....... 15727 ................Screw

 

7 ................1 ....... 11986 ................Side Cover

 

8 ................1 ....... 11979 ................Lever, Bypass

 

9 ................1 ....... 11989 ................Screw, Hex Head, 1/4-14

 

10 ..............1 ....... 60040SS ...........Bypass Valve, 5600, 3/4" NPT 

Blk Grip Lever, SS 

 

 

 ........ 60041SS ...........Bypass Valve, 5600, 1" NPT Blk 

Grip Lever, SS

60040SS Rev T

60041SS Rev U

BYPASS VALVE ASSEMBLY

4 • AP10 Fleck 4650

Содержание Fleck 4650

Страница 1: ...of Day Arrow BR61501 4650 Rev A Figure 1 1 Manually index the softener control into the service position and let water flow into the resin tank When the water flow stops open a softened water tap unt...

Страница 2: ...24 Hour Gear Assembly Silver 13 1 13011 Cycle Actuator Gear 14 1 14177 Knob Manual Regeneration 15 4 13300 Ball 1 4 Dia 16 2 13311 Spring Detent Skipper Wheel 17 1 14207 Knob Label Silver 18 1 14176 V...

Страница 3: ...021 560CD HW 22 1 13163 Injector Body 23 1 10225 xx Injector Nozzle Hot Water 1 10913 xx Injector Nozzle Cold Water 24 1 10226 xx Injector Throat Specify Size Hot Water 1 10914 xx Injector Throat Spec...

Страница 4: ...Plug Bypass 4 1 11978 Side Cover 5 1 13604 03 Label 6 8 15727 Screw 7 1 11986 Side Cover 8 1 11979 Lever Bypass 9 1 11989 Screw Hex Head 1 4 14 10 1 60040SS Bypass Valve 5600 3 4 NPT Blk Grip Lever SS...

Страница 5: ...hole in the piston over the top edge of the piston and out the drain line 3 Backwash Position 10 Minutes Hard water enters the unit at the valve inlet flows around the lower piston groove and lower p...

Страница 6: ...k passage around the upper piston groove and out the drain line 7 Settling Rinse Position 5 Minutes Hard water enters the unit at the valve inlet flows around the lower piston groove down thru the top...

Страница 7: ...normal service position Water pressure should now be applied to the conditioner and any bypass line shut off 12 Check for leaks at all seal areas Check drain seal with the control in the backwash posi...

Страница 8: ...lace timer mounting screws Replace screw and washer at drive yoke 11 Return bypass or inlet valving to normal service position Water pressure should now be applied to the conditioner and any bypass li...

Страница 9: ...nt work done on plumbing system Remove piston and clean control Loss of resin through drain line Air in water system Ensure that well system has proper air eliminator control Check for dry well condit...

Страница 10: ...Cold Water 60032 001 Brine Valve Hot Water 60514 Brine Cam 3 18 60514 01 Brine Cam 6 36 60514 02 Brine Cam Minutes 60510 Coupling with Clip and Screws 60040 Bypass Brass 3 4 NPT Cold Water 60041 Bypas...

Страница 11: ...Fleck 4650 AP10 11...

Страница 12: ...2010 Pentair Residential Filtration LLC 40261 Rev C AP10...