Page 5
WARNING
The unit should be located on a solid, level, horizontal surface and securely
fixed. Ensure free air-flow to all sides of the unit.
WARNING
Never use an extension cable to connect the unit to the electric power supply
If there is no suitable earthed supply available, have one installed by a quali-
fied electrician.
WARNING
Do not move/repair the unit yourself - Before carrying out any maintenance,
service or repair work, the product must be isolated from the mains electri-
cal supply. To prevent possible injury, only qualified engineers should carry
out these works.
WARNING
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or
instruction concerning the use of the appliance by a person responsible
for their safety. Please ensure that young children are supervised to
ensure that they do not play with the appliance.
WARNING
Do not install the unit in a place where there is a chance of flamma-
ble gas leaks. If there is a gas leak and gas accumulates in the area
surrounding the unit, it could cause an explosion.
WARNING
Water Connections - All plumbing connections should be carried out
as per the instructions in this manual. Failure to do so could result in
water damage to property.
WARNING
Cleaning the Unit - To prevent injury always shut the power ‘OFF’
when cleaning or servicing the unit. Avoid contact with the fan when
running as this will cause serious injury.
WARNING
Error Codes - If an error code occurs or you can smell burning, isolate
the unit immediately and call your local installer.
General Installation Information
1. All wiring work must be performed by a licensed electrician, and must conform to all national, state,
and local codes.
2. Installer to provide drainage of compartment for electrical components.
3. Power to all circuits must be supplied via a suitably sized Residual Current Device (RCD) in the fixed
wiring.
4. An Earth terminal is located inside the supply terminal box. To reduce the risk of electric shock, this
terminal must be connected to the grounding means provided in the electric supply service panel with
a continuous copper wire equivalent in size to the circuit conductors supplying this equipment and as
per the wiring rules.
5. The electrical supply for this product must include a suitably rated switch or circuit breaker to open
all ungrounded supply conductors to comply with the Wiring Rules. The disconnecting means must be
readily accessible to the occupant.
6. Supply conductor must be sized to support all loads.
Notices and Warnings (Continued)
Notices and Warnings