36
PLACING CONDITIONER INTO OPERATION (turning on the water)
Rev E
hose connections. C2 should be displayed.
8. If the water level is receding from the regenerant tank you can then
advance the controller back to the treated water (C0) position by pressing
SET and the UP buttons simultaneously to advance the controller to the
C0 position.
9. Finally, turn on a faucet plumbed after the water conditioner. Run the
faucet until the water runs clear. Add regenerant to the regenerant tank.
Things You Might Need to Know
•
When the controller is first plugged in, it may display a flashing hourglass
and the message Err 3, this means that the controller is rotating to the
home position. If the Err 2 is displayed, check that the incoming power
frequency matches the controller. The North American controller will not
run with 50 Hz input.
•
The preset default time of regeneration is 2:00 AM.
•
English or Metric? The World controller senses the electrical input and
decides which is needed. The North American controller only runs on 60
Hz and defaults to English units.
•
The 700 Series controller can be programmed to regenerate on specific
days of the week.
•
If electrical power is not available, the camshaft can be rotated
counterclockwise by hand if the motor is removed.
•
The 700 Series controllers send commands to the motor for camshaft
movement. However, water pressure/flow are required during the
regeneration cycle for backwash, purge and refill, and brine draw to
actually take place.
•
Make sure control power source is plugged in. The transformer should be
connected to a non-switched power source.
•
You can start programming at the beginning by resetting the amount of
media. When viewing H0 (History Value) push and hold SET for five
seconds. The display reverts back to
---
and any programmed
information is lost. Return to
700 Series Initial Power Up
.