Performa Valve
Service Position
Brine Tank
Mineral Tank
Drain
Inlet
Outlet
Hard Water
Soft Water
5
4
1
3
2
6
7
Valve No.
1-Closed
2-Closed
3-Open
4-Open
5-Closed
6-Closed
7-Closed
Brining/Slow Rinse Position
Brine Tank
Mineral Tank
Drain
Inlet
Outlet
Hard Water
Soft Water
5
4
1
3
2
6
7
Valve No.
1-Open
2-Open
3-Closed
4-Closed
5-Closed
6-Open
7-Closed
Backwash Position
Brine Tank
Mineral Tank
Drain
Inlet
Outlet
Hard Water
Soft Water
5
4
1
3
2
6
7
Backwash
Flow
Control
Valve No.
1-Closed
2-Open
3-Closed
4-Open
5-Closed
6-Closed
7-Open
Repressurize Position
Brine Tank
Mineral Tank
Drain
Inlet
Outlet
Hard Water
Soft Water
5
4
3
2
7
1
6
Valve No.
1-Closed
2-Open
3-Closed
4-Closed
5-Closed
6-Closed
7-Closed
FLOW DIAGRAMS
CONTINUED
42
•
AUTOTROL
®
740/760 Control 255 & Performa Series Valves (268, 268FA) Service Manual
Содержание AUTOTROL 740
Страница 1: ...AUTOTROL 740 760 CONTROL 255 PERFORMA SERIES VALVES 268 268 FA SERVICE MANUAL www pentairaqua com...
Страница 45: ...AUTOTROL 740 760 Control 255 Performa Series Valves 268 268FA Service Manual 45...
Страница 46: ...46 AUTOTROL 740 760 Control 255 Performa Series Valves 268 268FA Service Manual...
Страница 47: ...AUTOTROL 740 760 Control 255 Performa Series Valves 268 268FA Service Manual 47...