TROUBLESHOOTING - GENERAL
Possible Cause
Remedy
Heater will not come on
Automatic ignition system fails
Check if electrical connections are
correct and securely fastened –
If YES, call serviceman.
Pump not running
Place pump in operation
Pump air locked
Check for leaks
Filter dirty
Clean filter
Pump strainer clogged
Clean strainer
Defective wiring or connection
Repair or replace wires
Defective pressure switch
Replace Switch
Defective gas controls
Call serviceman
On-Off switch in "OFF" position
Turn switch to "ON"
Heater Short Cycling
(Rapid On and Off Operation)
Insufficient water flow
Clean filter and pump strainer
Defective wiring
Repair or replace wiring
Defective or stuck by-pass valve
Call serviceman
Defective hi-limit and/or thermostat
Call serviceman
Heater Makes Knocking Noises,
Make sure all valves on systems are open
Heater operating after pump has shut off
Shut off gas supply and call serviceman
Heater exchanger scaled
Shut off gas supply and call serviceman