SYSTEM START UP
Initial Power-Up
Initial Power Up – (Camshaft proceeds to HOME position)
Time & Day
Regen Time & Day
Salt
Capacity
Hardness
SU MO TU WE TH FR SA DAYS
• At initial power-up, the camshaft may need to rotate to
the HOME (in service position).
• Camshaft may take 1 to 2 minutes to return to
HOME position.
• Err 3 will be displayed until the camshaft returns to
HOME position.
• If more than 2 minutes elapses, verify that the motor is
turning the camshaft. If it is not turning, contact Dealer.
NOTE:
The 700 Series controller features a self-test
sequence. At first power-up of the control, you
may see a number such as 1.00, 1.02, 1.04, or 2.00
displayed. This is an indication that the self-test is not
completed. To complete the test, verify that the turbine
cable is connected. Blow air into the turbine port (valve
outlet) to spin the turbine. The controller will verify
that the turbine works and the self-test will finish.
Proceed with the initial start-up procedure.
Initial Start-up Step-By-Step Instructions
For FA filter applications, please program as normal below. See
section Programming the 700 for FA Filter Applications.
Step 1: Select Valve Type
This step may have been performed by your system’s OEM
manufacturer. In this case, proceed to step 2.
• Identify your valve body type by looking at the silver ID
sticker on the back or side of the valve body.
• Select your valve body type using the UP or DOWN
buttons.
• Display Valve Body
255
255, conditioner
263
Performa filter 263, filter
268
Performa conditioner 268, conditioner
273
Performa Cv 273, filter
278
Performa Cv 278, conditioner
293
Magnum Cv filter, filter
298
Magnum Cv conditioner, conditioner
NOTE:
Different 742/762 control hardware is necessary to
operate the 150S valve body.
Step 2: Program System Size
Time & Day
Regen Time & Day
Salt
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
This step may have been performed by your system’s OEM
manufacturer. In this case, proceed to step 3.
NOTE:
Capacity is the result of the amount of media in the
tank and the salt setting. The default capacity will be
changed by selecting a different regenerant setting.
• Input system size – media volume (For FA filters, choose
your closest media volume) – in cubic feet or liters.
• Use UP and DOWN buttons to scroll through resin
volume choices.
• Choose the nearest volume to your actual system size.
• Press SET to accept the system size you’ve selected.
• If incorrect setting is programmed, see “Resetting the
Control” section below.
NOTE:
If the controller was incorrectly set to the wrong valve
body, press the DOWN button and SET button for
five seconds to display resin volume in "HO". Press
and hold the SET button for five seconds to reset the
controller. Use the UP or DOWN buttons to increment
the display to the correct valve body. Press SET.
Step 3: Program Time of Day
Time & Day
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
• While “12:00” is blinking, set the correct time of day.
• Use the UP and DOWN buttons to scroll to the correct
time of day.
• “PM” is indicated, “AM” is not indicated.
• Press SET to accept the correct time of day and advance
to the next parameter.
Step 4: Set Day of Week
Time & Day
Regen Time & Day
Salt
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
• Press SET to make the arrow under “SU” flash.
• Use the UP and DOWN buttons to advance the arrow until
it is under the correct day of week.
• Press SET to accept and advance to the next parameter.
After steps 1-4, the controller will operate most systems.
Proceed to step 5 if further adjustments to your system’s
programming is needed.
Step 5: Set Regen Time
Time & Day
Regen Time & Day
Salt
SU MO TU WE TH FR SA DAYS
Capacity
Hardness
• 2:00 (AM) is the default time of regeneration. To accept
this time, press the DOWN button to move to step 6.
• To change the regen time, press SET – causing “2:00”
to flash.
• Use the UP and DOWN buttons to advance to the desired
regen time.
• Press SET to accept the time and advance to the
next parameter.
16
•
AUTOTROL
742/762 Control 255 & Performa Series Valves (263, 268, 268FA) Service Manual
Содержание 255-742-075-844
Страница 45: ...AUTOTROL 742 762 Control 255 Performa Series Valves 263 268 268FA Service Manual 45...
Страница 46: ...46 AUTOTROL 742 762 Control 255 Performa Series Valves 263 268 268FA Service Manual...
Страница 47: ...AUTOTROL 742 762 Control 255 Performa Series Valves 263 268 268FA Service Manual 47...