EQUIPMENT INSTALLATION
CONTINUED
Front
Time & Day
Regen Time & Day
Salt
SU MO TU WE TH FR SA DAYS
LBS
PM
MIN
KG
x100
x2
P
H
C
Capacity
Hardness
LCD Display
Manual Regen
Button
Down
Button
Set
Button
Up
Button
Back
Main Motor &
Optical Sensor
Connection
No Salt Detector
Connection
AC Adapter
(low voltage)
Input
742/762 Turbine Input or
Dry Contact Signal Input
Figure 4 700 Series Controller Identification
Location Selection
Location of a water treatment system is important. The
following conditions are required:
• Level platform or floor
• Room to access equipment for maintenance and adding
regenerant (salt) to tank.
• Ambient temperatures over 34°F (1°C) and below
120°F (49°C).
• Water pressure below 125 psi (8.61 bar) and above
20 psi (1.4 bar).
• In Canada the water pressure must be below
100 psi (6.89 bar).
• Constant electrical supply to operate the controller.
• Total minimum pipe run to water heater of ten feet (three
meters) to prevent backup of hot water into system.
• Local drain for discharge as close as possible.
• Water line connections with shutoff or bypass valves.
• Must meet any local and state codes for site of installation.
• Valve is designed for minor plumbing misalignments. Do
not support weight of system on the plumbing.
• Be sure all soldered pipes are fully cooled before
attaching plastic valve to the plumbing.
Outdoor Locations
When the water conditioning system is installed outdoors,
several items must be considered.
• Moisture — The valve and 700 controller are rated
for NEMA 3 locations. Falling water should not affect
performance. The system is not designed to withstand
extreme humidity or water spray from below. Examples
are: constant heavy mist, near corrosive environment,
upwards spray from sprinkler.
12
•
AUTOTROL
742/762 Control 255 & Performa Series Valves (263, 268, 268FA) Service Manual