Pentair 188623 Скачать руководство пользователя страница 2

IMPORTANT WARNING AND SAFETY INSTRUCTIONS

This guide provides installation and operation instructions for 

this product. Consult Pentair with any questions regarding this 

equipment.
Attention Installer:

 

This guide contains important information about the 

installation, operation and safe use of this product. This information should 
be given to the owner and/or operator of this equipment after installation 
or left on or near the filter.

Attention User: 

This manual contains important information that will 

help you in operating and maintaining this filter. Please retain it for future 
reference.

Important Notice:

 

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

This is the safety alert symbol. When you see this symbol 

on your system or in this manual, look for one of the 

following signal words and be alert to the potential for 

personal injury.
Warns about hazards that can cause death, serious 

personal injury, or major property damage if ignored.
Warns about hazards that may cause death, serious 

personal injury, or major property damage if ignored.
Warns about hazards that may or can cause minor 

personal injury or property damage if ignored.

       

NOTE

       Indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this manual and on 

equipment. Keep safety labels in good condition; replace if missing or 

damaged.

Never exceed the maximum operating pressure of 
the system components. Exceeding these limits 
could result in a component failing under pressure. 
This instantaneous release of energy can cause 
the closure to separate and could cause severe 
personal injury or death if they were to strike a 
person.

Due to the potential risk that can be involved it is 
recommended that the pressure test be kept to 
the minimum time required by the local code. Do 
not allow people to work around the system when 
the circulation system is under pressure test. Post 

appropriate warning signs and establish a barrier around the pressurized 
equipment. If the equipment is located in an equipment room, lock the 
door and post a warning sign. 
Never attempt to adjust any closures or lids or attempt to remove or 
tighten bolts when the system is pressurized. These actions can result in 
a separation or failure of system components. This instantaneous release 
of energy can cause components to be accelerated to high velocities and 
to travel far distances. These components could cause severe personal 
injury or death if they were to strike a person.

RISK OF ELECTRICAL SHOCK OR 
ELECTROCUTION.

This filter must be installed by a qualified service 
professional in accordance with the National Electrical 
Code and all applicable local codes and ordinances. 
Always disconnect power to the equipment at the 

circuit breaker before servicing any of the equipment. Ensure that the 
disconnected circuit is locked out or properly tagged so that it cannot be 
switched on while you are working on the pool equipment. Failure to do 
so could result in serious injury or death to serviceman, pool users or 
others due to electric shock. 
Position the filter and the air relief valve to safely direct water drainage and 
purged air or water. Water discharged from an improperly positioned filter 
or valve can create an electrical hazard that can cause severe personal 
injury as well as damage property. 

Consumer Information and Safety 

This filter is designed and manufactured to provide many years of safe 
and reliable service when installed, operated and maintained according 
to the information in this manual and the installation codes referred to in 
later sections. Throughout the manual, safety warnings and cautions are 
identified by the “      ” symbol. Be sure to read and comply with all of the 
warnings and cautions.

Before installing this product, read and follow all 
warning notices and instructions which are included. 

Failure to follow safety warnings and instructions can result in severe 
injury, death, or property damage.  Call (800) 831-7133 for additional free 
copies of these instructions. 

Do not operate the filter until you have read and 
understand clearly all the operating instructions and 

warning messages for all equipment that is a part of the pool circulating 
system. The following instructions are intended as a guide for initially 
operating the filter in a general pool installation, however each installation 
may have unique conditions where the starting procedure could be 
different. Failure to follow all operating instructions and warning messages 
can result in severe injury, death, or property damage.

To avoid this potential hazard, follow these instructions:
1.  Before repositioning valve(s) and before beginning the assembly, 

disassembly, or adjustment of the clamp or any other service of the 
circulating system: (A) Turn the pump 

OFF

 and 

shut OFF 

any automatic 

controls to ensure the system is NOT inadvertently started during the 
servicing; (B) open the

 

manual air relief valve; (C) stand clear of the 

filter; (D) wait until all pressure is relieved.

2.   Whenever installing the filter clamp 

FOLLOW THE

 

FILTER CLAMP 

INSTALLATION INSTRUCTIONS EXACTLY

.

3.   Once service on the circulating system is complete 

FOLLOW SYSTEM 

RESTART INSTRUCTIONS EXACTLY

.

4.   Maintain circulation system properly. Replace worn or damaged parts 

immediately, (e.g., clamp, pressure gauge, valve(s), o-rings, etc).

5.   Be sure that the filter is properly mounted and positioned according 

to instructions provided.

FILTER OPERATES UNDER HIGH PRESSURE.

When any part of the circulating system, (e.g., clamp, 

pump, filter, valve(s), etc.), is serviced, air can enter 

the system and become pressurized. Pressurized 

air can cause the lid to separate which can result in 

severe injury, death, or property damage.

Do not permit children to use or operate this filter. 

Use only a PTFE or silicone based lubricant when 
lubricating the O-rings on the union and bulkhead 

couplings. Use of petroleum based products will damage the equipment.

FULLFLO

XF

® 4000-SERIES Grid Style D.E. Filter Installation and User’s Guide

 

i

Содержание 188623

Страница 1: ...reat force To reduce the risk of severe injury or death relieve pressure by opening air relief valve before opening filter Before starting the pump after servicing ensure that clamp band is correctly...

Страница 2: ...cannot be switched on while you are working on the pool equipment Failure to do so could result in serious injury or death to serviceman pool users or others due to electric shock Positionthefilteran...

Страница 3: ...and pump during system start up shut down or servicing of the system filter General Installation Information The following information should be read carefully since it outlines the proper manner of...

Страница 4: ...ation System Start Up and Operation Opening the Filter Preparing Diatomite Coating Filter Elements with D E Valve Operation Installing the Filter Lid and Clamp Ring Start Up Instructions TABLE OF CONT...

Страница 5: ...ximum pressure stated on each component of the system 4 The pressure gauge is the primary indicator of how the filter is operating Maintain your pressure gauge in good working order refer to Maintaini...

Страница 6: ...emove the filter lid for cleaning and servicing This distance will vary with the model of filter you are using See Table 1 for the required vertical clearance 6 Position the filter to safely direct wa...

Страница 7: ...ressure gauge connection threads with thread seal tape two full wraps of tape will be enough 6 Thread the pressure gauge into the top of the manual air relief valve Hand tighten only 7 Follow Start up...

Страница 8: ...priate size concrete anchor to mount the clamp to the equipment pad Be sure to follow local codes 3 Fit the hook of each clamp into the anchor slots on the base panel of the filter See Figure 3 4 Mark...

Страница 9: ...y to prevent the lid from separating during system start up operation or servicing REQUIRED TOOLS Ratchet Wrench 7 8 Socket Socket Extender if needed PROCEDURE 1 Shut off pump and relieve pressure a T...

Страница 10: ...with sufficient water in a bucket to make a thin milky mixture 3 Refer to Coating the Filter Elements with D E for instruction on introducing the diatomite slurry into the filter Follow all manufactur...

Страница 11: ...clamp to fit the clamp properly c Continue to tighten until the spring coils touch d Tap around the entire clamp again and verify the spring coils remain touching If not continue to tighten the nut N...

Страница 12: ...vice at 800 831 7133 for assistance 5 After a steady stream of water appears close the manual air relief valve by turning the valve cover assembly a quarter turn clockwise 6 The first time the system...

Страница 13: ...cannot assume any responsibility for torn or damaged bags if left in the sun to dry 10 If your filtration system contains a Separation Tank follow the instructions in Cleaning the Separation Tank on p...

Страница 14: ...are present a Soak the filter element for at least one hour overnight is most effective in one of the following A commercial filter cleaner One cup trisodium phosphate TSP to five gallons of water On...

Страница 15: ...O ring is properly seated around the entire tank to prevent pinching 9 Install the clean bag in tank with the rim of the bag immediately below the tank inlet opening then push down on the rim opposit...

Страница 16: ...ution Allow the elements to soak in the solution for 10 minutes or until bubbling stops 5 Turn the elements over placing the top halves into the solution Allow the top halves of the elements to soak f...

Страница 17: ...manual air relief valve by turning the valve cover assembly a quarter turn counter clockwise until it snaps into the full open position c Stand clear of the filter and wait until all pressure is relie...

Страница 18: ...on filter elements Clean the filter elements according to Manually Cleaning the Filter Elements page 10 and or Acid Soaking the Filter Elements page 12 Cloud of Dirt Entering Pool A brief cloud of di...

Страница 19: ...rawings FullFloXF 4000 Series Grid Style D E Filter Model P N Filter Area sq ft Vertical Clearance Required Flow Rate GPM Res Turnover Capacity Gallons 8 hrs 10 hrs 12 hrs XF4048 188623 48 65 96 45 12...

Страница 20: ...nd approved by Pentair and original Pentair parts you simultaneously acquire the assurance that they have been thoroughly tested by Pentair to ensure optimum performance when installed on your filter...

Страница 21: ...FULLFLOXF 4000 SERIES Grid Style D E Filter Installation and User s Guide 17 NOTES...

Страница 22: ...FULLFLOXF 4000 SERIES Grid Style D E Filter Installation and User s Guide 18 NOTES...

Страница 23: ...FULLFLOXF 4000 SERIES Grid Style D E Filter Installation and User s Guide 19 NOTES...

Страница 24: ...r trademarks and logos are property of Pentair Third party registered and unregistered trademarks and logos are the property of their respective owners Because we are continuously improving our produc...

Отзывы: