IMPORTANT WARNING AND SAFETY INSTRUCTIONS

HAZARDOUS PRESSURE: STAND CLEAR OF 
PUMP AND FILTER DURING START UP

Circulation systems operate under high pressure. 
When any part of the circulating system (i.e. 
locking ring, pump, filter, valves, etc.) is serviced, 
air can enter the system and become pressurized. 

Pressurized air can cause the pump housing cover filter lid and valves to 
violently separate which can result in severe personal injury or death. Filter 
tank lid and strainer cover must be properly secured to prevent violent 
separation. Stand clear of all circulation system equipment when turning 
on or starting up pump. 
Before servicing equipment, make note of the filter pressure. Be sure 
that all controls are set to ensure the system cannot inadvertently start 
during service. Turn off all power to the pump.

 

IMPORTANT: Place filter 

manual air relief valve in the open position and wait for all pressure 
in the system to be relieved. 

Before starting the system, fully open the manual air relief valve and place 
all system valves in the “open” position to allow water to flow freely from the 
tank and back to the tank. Stand clear of all equipment and start the pump.  

IMPORTANT: Do not close filter manual air relief valve until all 
pressure has been discharged from the valve and a steady stream 
of water appears. 

Observe filter pressure gauge and be sure it is not 

higher than the pre-service condition.

The following information should be read carefully 
since it outlines the proper manner of care and 

operation for your filter system. As a result of following these instructions 
and taking the necessary preventative care, you can expect maximum 
efficiency and life from your filtration system.

For Installation of Electrical Controls at Equipment Pad (ON/OFF 
Switches, Timers and Automation Load Center)

Install all electrical controls at equipment pad, such 
as on/off switches, timers, and control systems, 
etc. to allow the operation (startup, shut-down, or 
servicing) of any pump or filter so the user does not 
place any portion of his/her body over or near the 
pump strainer lid, filter lid or valve closures. 

This installation should allow the user enough space to stand clear of 
the filter and pump during system start-up, shut down or servicing of the 
system filter.

FULLFLO

XF

®

 Q-SERIES Cartridge Style D.E. Filter Installation and User’s Guide

General Installation Information

The following information should be read carefully since it outlines the 
proper manner of care and operation for your filter system. 
You can expect maximum efficiency and life from your filtration system by 
following these instructions and taking the necessary preventative care.
•  Have a trained pool professional perform all pressure tests.
•  Do not connect the system to a high pressure or city water system.
•  Trapped air in the system can create a hazardous condition. BE SURE 

to purge all air from the system before operating or testing equipment.

•  DO NOT pressure test with compressed air!
•  Piping must conform to local/state plumbing and sanitary codes.
•  Support piping independently to prevent strains on filter or valve.
•  Fittings restrict flow; for best efficiency, use the fewest possible fittings.
•  A check valve installed ahead of the filter inlet will prevent contaminants 

from draining back into the pool.

•  A check valve installed between the filter and heater will prevent 

hot water from backing up into the filter and deforming the internal 
components.

•  All wiring, grounding and bonding of associated equipment must meet 

local and/or National Electrical Code standards.

SERIOUS BODILY INJURY OR DEATH CAN RE-
SULT IF THIS FILTER IS NOT INSTALLED AND 

USED CORRECTLY.

INSTALLERS, POOL OPERATORS AND POOL 
OWNERS MUST READ THESE WARNINGS AND 

ALL INSTRUCTIONS BEFORE USING THIS FILTER.

This filter is intended for use in swimming pool 
applications. Most states and local codes regulate 

the construction, installation, and operation of public pools and spas, 
and the construction of residential pools and spas. It is important to 
comply with these codes, many of which directly regulate the installation 
and use of this product. Consult your local building and health codes for 
more information.

SAVE THESE INSTRUCTIONS

IMPORTANT: 

Keep all warning labels in good condition. If any warnings 

labels are damaged, missing, or become illegible call Pentair Customer 
Service at 1-800-831-7133 and request replacement labeling.

ii

Содержание 188613

Страница 1: ...vicing ensure that clamp band is correctly fastened See Important Warnings and Safety Instructions page i and follow all instructions exactly including the Opening the Filter page 5 Installing the Filter Lid and Clamp Ring page 7 and Start Up Instructions page 8 IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE FULLFLOXF Q SERIES C...

Страница 2: ...re that the disconnected circuit is locked out or properly tagged so that it cannot be switched on while you are working on the pool equipment Failure to do so could result in serious injury or death to serviceman pool users or others due to electric shock Positionthefilterandtheairreliefvalvetosafelydirectwaterdrainageand purged air or water Water discharged from an improperly positioned filter o...

Страница 3: ...filter lid or valve closures This installation should allow the user enough space to stand clear of the filter and pump during system start up shut down or servicing of the system filter FULLFLOXF Q SERIES Cartridge Style D E Filter Installation and User s Guide General Installation Information The following information should be read carefully since it outlines the proper manner of care and opera...

Страница 4: ...the Manual Air Relief Valve Anchor Clamp Installation System Start Up and Operation Opening the Filter Preparing Diatomaceous Earth D E Coating the Filter Cartridges with D E Installing the Filter Lid and Clamp Ring Start Up Instructions TABLE OF CONTENTS ii 1 1 1 1 1 2 2 2 3 4 5 5 6 6 7 8 9 9 9 10 11 12 12 13 14 14 14 14 15 If you have questions about ordering Pentair replacement parts and pool p...

Страница 5: ...e water the filter cloth merely supports the diatomaceous earth Operating without diatomaceous earth will damage filter cartridges and shorten filtering cycles Maintaining the Pressure Gauge The pressure gauge is the primary indicator of how the system operates It is critical to keep the pressure gauge in good condition Replace pressure gauge P N 190058 if any of the requirements below are not met...

Страница 6: ...r or water Water discharged from an improperly positioned filter or valve can create an electrical hazard as well as damage property 7 Install the manual air relief valve and pressure gauge before use See Installing the Manual Air Relief Valve on the next page Table 1 Vertical Clearance Model P N Size Required Q80 188627 80 sq ft 65 in Q100 188613 100 sq ft 80 in Q120 188616 120 sq ft 80 in INSTAL...

Страница 7: ...anything that might be damaged 4 Remove the plug from the top of the manual air relief valve with a 9 16 wrench 5 Wrap the pressure gauge connection threads with thread seal tape two full wraps of tape will be enough 6 Thread the pressure gauge into the top of the manual air relief valve Hand tighten only 7 Follow Start up Instructions exactly page 8 VALVE PLUG PRESSURE GAUGE FILTER TANK Figure 2 ...

Страница 8: ...and the appropriate size concrete anchor to mount the clamp to the equipment pad Be sure to check local codes 3 Fit the hook of each clamp into the anchor slots on the base panel of the filter See Figure 3 4 Mark the position of the hole in each clamp on the equipment pad 5 Use a masonry drill bit and drill a hole in the cement with a diameter as determined by the concrete anchor at each of the ma...

Страница 9: ...he filter tank 3 Loosen the clamp s barrel nut with a 7 8 wrench allowing the spring coils to decompress See Figure 6 Remove the barrel nut spring and two washers from the T bolt and place them in a safe place where they will not be lost 4 Once the spring has fully decompressed the clamp assembly will rest in the open position Carefully lift the filter lid straight up from the lower body of the fi...

Страница 10: ... 2 Filter Area Weight of No of 1 lb sq ft D E Coffee Cans 80 8 lbs 16 100 10 lbs 20 120 12 lbs 24 Coating the Filter Cartridges with D E The following information should be read carefully since it outlines the proper manner of care and operation for your filter system You can expect maximum efficiency and life from your filtration system by following these instructions and taking the necessary pre...

Страница 11: ...p ring to fit the clamp ring properly c Continue to tighten until the spring coils touch d Tap around the entire clamp ring again and verify the spring coils remain touching If not continue to tighten the nut Note The clamp ring is installed correctly only when the spring coils remain touching after tapping the clamp ring See Figure 7 7 Close the waste drain plug at the bottom of the filter 8 Foll...

Страница 12: ...ll Pentair Technical Service at 800 831 7133 for assistance 5 After a steady stream of water appears close the manual air relief valve by turning the valve cover assembly a quarter turn clockwise 6 The first time the system is started up fill out Table 3 a Record the Original Starting Pressure b Fill in the pressure at which to clean the filter 8 10 psi higher than the Original Starting Pressure c...

Страница 13: ... the servicing B open the manual air relief valve C stand clear of the filter D wait until all pressure is relieved 2 Whenever installing the filter clamp FOLLOW THE FILTER CLAMP INSTALLATION INSTRUCTIONS EXACTLY 3 Once service on the circulating system is complete FOLLOW SYSTEM RESTART INSTRUCTIONS EXACTLY 4 Maintain circulation system properly Replace worn or damaged parts immediately e g clamp ...

Страница 14: ...s where high levels of perspiration suntan lotions and other oils are present a Soak the cartridge for at least one hour overnight is most effective in one of the following A commercial filter cleaner 1 cup trisodium phosphate TSP to 5 gallons of water 1 cup dishwasher detergent to 5 gallons of water b Rinse the cartridge to remove oils and cleaning solution 10 Direct the water spray to wash out t...

Страница 15: ...he cartridges to soak in the solution for 10 minutes or until bubbling stops 5 Turn the cartridges over placing the top halves into the solution Allow the top halves of the cartridges to soak for 10 minutes or until bubbling stops 6 Remove the cartridges from the acid solution 7 Using a garden hose with a straight flow nozzle thoroughly wash down the entire filter cartridge Wash from the top down ...

Страница 16: ...nk s air passage is open by inserting a 5 16 drill bit through the valve body c Verify that the valve stem O rings are in good condition properly positioned and lubricated with a silicone base lubricant 5 Reinstall the valve stem and cover assembly with a downward and clockwise motion until it snaps into position Figure 13 Replacing Filter Cartridges Filter cartridge life will vary with pool condi...

Страница 17: ...ol is diatomaceous earth Internal parts not assembled correctly Check assembly of internal parts making sure they are correctly installed Damaged manifold Replace manifold Damaged filter cartridge Replace cartridge Diatomaceous earth back up at main drain Check for air leaks and repair as needed Air leaks can cause system to drain down allowing D E back to the pool Missing air bleed screen cap Rep...

Страница 18: ...00 129 600 188616 Q120 120 80 180 86 400 108 000 129 600 Recommended Flow Rates Note Actual system flow will depend on plumbing size and other system components Required clearance to remove filter cartridges Maximum flow rate Head Loss Comparison Curves DIM A 23 58 4 cm 15 5 39 4 cm 21 5 54 6 cm 23 5 56 7 cm 22 5 57 2 cm MODEL DIM A Q80 42 6 108 2 cm Q100 55 6 141 2 cm Q120 55 6 141 2 cm Dimension...

Страница 19: ...k Bottom 175401 1 175402 1 175403 1 2 Filter Cartridge 178655 4 178656 4 178750 4 3 Clamp Ring Assembly 190033 1 1 1 4 O Ring Tank 39010200 1 1 1 5 Bulkhead Kit 178829 2 2 2 6 Tank Lid Short 178832 1 Tank Lid Tall 178833 1 1 7 Pressure Relief Valve 98209803 1 1 1 8 Drain Plug 178816 2 2 2 9 Support Pipe Small 178697 4 4 Support Pipe Large 178696 4 10 Top Manifold Kit 178838 1 1 1 11 Diamond Seal K...

Страница 20: ...ir trademarks and logos are property of Pentair Third party registered and unregistered trademarks and logos are the property of their respective owners Because we are continuously improving our products and services Pentair reserves the right to change specifications without prior notice 2021 Pentair All rights reserved This document is subject to change without notice ...

Отзывы: