14
FULLFLO
XF
®
Q-SERIES Cartridge Style D.E. Filter Installation and User’s Guide
TECHNICAL DATA
Product #
Model #
Filter Area
Sq. Ft.
Vertical*
Clearance
Flow Rate
GPM
Res. Turnover Capacity (Gallons)
8 hours
10 hours
12 hours
188627
Q80
80
65”
160
76,800
96,000
115,200
188613
Q100
100
80”
180
86,400
108,000
129,600
188616
Q120
120
80”
180
86,400
108,000
129,600
Recommended Flow Rates
Note:
Actual system flow will depend on plumbing size and other system components.
*
Required clearance to remove filter cartridges.
**
Maximum flow rate.
Head Loss Comparison Curves
DIM “A”
23”
58.4 cm
15.5”
39.4 cm
21.5”
54.6 cm
23.5”
56.7 cm
22.5”
57.2 cm
MODEL
DIM "A"
Q80
42.6" (108.2 cm)
Q100
55.6" (141.2 cm)
Q120
55.6" (141.2 cm)
Dimensional Drawings
0
1
2
3
4
5
6
7
8
9
10
0
20
40
60
80
100
120
140
160
180
200
Pressure (psi
)
Flow (GPM)