POSI-CLEAR™ RP Cartridge Filter Installation and User’s Guide

5

Cleaning the Filter

1.  Turn the pump off, shut off any automatic controls to ensure that the system is not inadvertently started during 

servicing. 

2.  Open the filter High Flow™ manual air relief valve (and the waste drain valve, or cap, if your system has one).
3.  Remove hair and lint strainer pot lid and clean basket. Replace basket and secure lid.
4.  Disconnect air relief drain hose if installed.
5.  Remove lock ring by depressing safety latches on both sides of ring and rotate counterclockwise, then remove 

tank lid.

6.  Remove the element assembly by placing hands in lifting handles and pulling straight up on the element 

assembly.

7.  Remove the cartridge element from the center support tube. 
8.  Using a garden hose with a nozzle, direct water spray at the cartridge element to dislodge and wash away 

accumulated foreign matter. Water may be sprayed at the outside as well as the inside of the cartridge 

element for thorough cleaning.

7.  For cartridges used in pools or spas where high levels of perspiration, suntan lotions and other oils are 

present:

a.  Soak the cartridge for at least one hour (overnight is most effective) in one of the following:

•  A commercial filter cleaner

•  One cup trisodium phosphate (TSP) to five gallons of water
•  One cup dishwasher detergent to five gallons of water

b.  Rinse the cartridge to remove oils and cleaning solution.

8.  Direct the water spray to wash out the inside of the tank body and bottom manifold. Water and debris will drain 

out through the open drain plug.

9.   Check gasket around outer lip of bottom plate. Gasket must be firmly and evenly set around the entirety of the 

outer lip. 

9.  Turn the cartridge element over several times during the washing operation to clean the media thoroughly.
10.  Clean and remove debris from inside the filter tank and from the O-ring and O-ring groove on the tank body.
11.  Replace clean cartridge element on support tube and install assembly into the filter tank body, aligning the 

arrow on the support tube with the inlet port of the filter, making sure it is fully seated. Make sure the internal 

air relief screen is attached to the top of the element support tube.

12.  Replace the tank lid onto the tank body making sure it is fully and firmly seated on the tank body.
13.  Place lock ring over tank lid, and centering the lock ring on the threads of the tank body, turn the lock ring 

clockwise until the safety latches click and the lock ring hits the stops on the body. DO NOT ATTEMPT TO 

OVER-TIGHTEN THE LOCK RING AFTER LOCK RING HAS HIT THE STOPS ON THE BODY.

Note

: Any time the filter tank is opened, and/or element assembly is removed, be sure to generously 

coat the O-ring with silicone lubricant before reassembling the unit. DO NOT USE PETROLEUM BASED 

LUBRICANTS BECAUSE THEY HAVE A DETERIORATING EFFECT ON RUBBER.

14. Replace drain cap and reinstall manual air relief valve drain hose if used.

Replacing the Cartridge Element

Cartridge element life will vary with pool conditions such as bather load, wind, dust, etc. You can expect an 

average media life of three (3) years under normal conditions.

 

To replace cartridge element follow steps in 

Cleaning the Filter 

above.

The following information should be read carefully since it outlines the proper manner of care and operation for 
your filter system. As a result of following these instructions and taking the necessary preventative care, you can 

expect maximum efficiency and life from your filter system.

Heed all manufacturers' instructions and warnings when using polyhexamethylene biguanide sanitizers or other 
cartridge filter cleaner solutions.

Failure to remove all oils and cleaning solutions before acid soaking will result in permanent restriction of water 
flow through the filter and will cause premature cartridge failure.

Содержание 160350

Страница 1: ...POSI CLEAR RP CARTRIDGE FILTER IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE...

Страница 2: ...Instructions Maintenance Maintaining the Pressure Gauge Cleaning the Manual Air Relief Valve Cleaning the Filter Replacing Cartridge Element i 1 1 1 2 2 2 3 3 3 4 4 4 5 5 Troubleshooting Technical Da...

Страница 3: ...e filter to separate and could cause severe personal injury or death if they were to strike a person This filter must be installed by a qualified pool serviceman in accordance with all applicable loca...

Страница 4: ...pressure tests Pressures above 50 psi can damage your filter Be sure the maximum pressure of the filter system does not exceed the maximum pressure of any components within the system typically state...

Страница 5: ...his filter will operate in a safe manner 2 The maximum working pressure of this filter is 50 psi Never subject this filter to pressure in excess of this amount even when conducting hydrostatic pressur...

Страница 6: ...roperly positioned filter or valve can create an electrical hazard that can cause severe personal injury as well as damage property This filter must be installed by a qualified pool technician in acco...

Страница 7: ...equires a quarter turn counterclockwise Opening this valve rapidly releases air trapped in the filter 2 Stand clear of the filter tank then start the pump 3 Close the manual air relief valve after a s...

Страница 8: ...manual air relief valve by turning the valve cover assembly a quarter turn counter clockwise until it snaps into the full open position c Stand clear of the filter and wait until all pressure is relie...

Страница 9: ...ris from inside the filter tank and from the O ring and O ring groove on the tank body 11 Replace clean cartridge element on support tube and install assembly into the filter tank body aligning the ar...

Страница 10: ...owners are dismayed by the undesirable color and appearance of water in a newly filled pool Plaster dust can be responsible for short filter cycles requiring frequent cleaning 3 If pressure drops on...

Страница 11: ...n plumbing size and other system components Flow Rates Residential Maximum Cartridge Flow Rates Commercial Maximum Cartridge Flow Rates Model Product sq ft GPM GPH 6 hour 8 hour GPM GPH 6 hour 8 hour...

Страница 12: ...8 59053700 Center Core 100 sq ft Filter 9 59053800 Center Core 150 200 sq ft Filter 10 R173215 Cartridge Element 100 sq ft Filter 11 R173216 Cartridge Element 150 sq ft Filter 12 R173217 Cartridge El...

Страница 13: ...NOTES...

Страница 14: ...NOTES...

Страница 15: ...NOTES...

Страница 16: ...tries Unless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and...

Отзывы: