POSI-CLEAR™ RP Cartridge Filter Installation and User’s Guide

 

THIS SYSTEM OPERATES UNDER HIGH PRESSURE

 

When any part of the circulating system, (e.g., closure, pump, filter, valve(s), etc.), is serviced, air can enter the 
system and become pressurized. Pressurized air can cause the top closure to separate which can result in severe 
injury, death, or property damage. To avoid this potential hazard, follow these instructions:

1.  Let air and pressure out of system before and after servicing.

a.  

Shut off pump and RELIEVE PRESSURE by opening the manual air/pressure relief valve before 
servicing.

b. Follow 

Startup Instructions

 exactly after completing service (page 3). 

The air/pressure relief valve 

must remain open until water comes out

, allowing all air out of the system.

2.  Install lock ring properly. 

a.  Follow 

Lock Ring Installation Instructions

 exactly (page 3).

3.  Maintain circulation system properly to help prevent air entering the system.

a.   Replace worn or damaged parts immediately, (e.g., closure, pressure gauge, valve(s), O-rings, 

etc.).

b.   Maintain proper water level in the pool or spa.

4.   Verify that the return line to the pool is unobstructed. Ensure return valves are open and any winterizing 

plugs are removed.

AVOID DAMAGING SYSTEM

Never Exceed Maximum Pressure of Components. 

The maximum working pressure of this filter is 50 psi. Never 

subject this filter to higher pressure, even when conducting hydrostatic pressure tests. Pressures above 50 psi can damage your filter.
Be sure the maximum pressure of the filter system does not exceed the maximum pressure of any components within the system 
(typically stated on each component), including during hydrostatic or external leak tests. Exceeding the maximum pressure of a 
component can result in that component failing. If you do not know the pool or spa system operating pressure, install an ASME 
approved automatic Pressure Relief or Pressure Regulator in the circulation system set to the lowest working pressure of any of the 
components in the system. 

Certain codes may require pressure testing the system. Performing pressure tests increases the risk of 
component failure.  Due to the potential risk that can be involved, keep the pressure test to the minimum time 
required by the local code and take precautions. If pressure testing is necessary, follow these precautions:

1.  Keep people away.

a.   Do not allow people to work around the system when the circulation system is under pressure test. 

Post appropriate warning signs and establish a barrier around the pressurized equipment. If the 
equipment is located in an equipment room, lock the door and post a warning sign. 

2.  Never exceed maximum operating pressure.

a.   When performing hydrostatic pressure tests or when testing for external leaks of the completed filtration 

and plumbing system, ensure that the Maximum Pressure that the filtration system will be subjected 
to does not exceed the maximum working pressure of any of the components contained within the 
system.  

IMPORTANT WARNINGS AND SAFETY INSTRUCTIONS

iii

Содержание 160350

Страница 1: ...POSI CLEAR RP CARTRIDGE FILTER IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE...

Страница 2: ...Instructions Maintenance Maintaining the Pressure Gauge Cleaning the Manual Air Relief Valve Cleaning the Filter Replacing Cartridge Element i 1 1 1 2 2 2 3 3 3 4 4 4 5 5 Troubleshooting Technical Da...

Страница 3: ...e filter to separate and could cause severe personal injury or death if they were to strike a person This filter must be installed by a qualified pool serviceman in accordance with all applicable loca...

Страница 4: ...pressure tests Pressures above 50 psi can damage your filter Be sure the maximum pressure of the filter system does not exceed the maximum pressure of any components within the system typically state...

Страница 5: ...his filter will operate in a safe manner 2 The maximum working pressure of this filter is 50 psi Never subject this filter to pressure in excess of this amount even when conducting hydrostatic pressur...

Страница 6: ...roperly positioned filter or valve can create an electrical hazard that can cause severe personal injury as well as damage property This filter must be installed by a qualified pool technician in acco...

Страница 7: ...equires a quarter turn counterclockwise Opening this valve rapidly releases air trapped in the filter 2 Stand clear of the filter tank then start the pump 3 Close the manual air relief valve after a s...

Страница 8: ...manual air relief valve by turning the valve cover assembly a quarter turn counter clockwise until it snaps into the full open position c Stand clear of the filter and wait until all pressure is relie...

Страница 9: ...ris from inside the filter tank and from the O ring and O ring groove on the tank body 11 Replace clean cartridge element on support tube and install assembly into the filter tank body aligning the ar...

Страница 10: ...owners are dismayed by the undesirable color and appearance of water in a newly filled pool Plaster dust can be responsible for short filter cycles requiring frequent cleaning 3 If pressure drops on...

Страница 11: ...n plumbing size and other system components Flow Rates Residential Maximum Cartridge Flow Rates Commercial Maximum Cartridge Flow Rates Model Product sq ft GPM GPH 6 hour 8 hour GPM GPH 6 hour 8 hour...

Страница 12: ...8 59053700 Center Core 100 sq ft Filter 9 59053800 Center Core 150 200 sq ft Filter 10 R173215 Cartridge Element 100 sq ft Filter 11 R173216 Cartridge Element 150 sq ft Filter 12 R173217 Cartridge El...

Страница 13: ...NOTES...

Страница 14: ...NOTES...

Страница 15: ...NOTES...

Страница 16: ...tries Unless expressly noted names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and...

Отзывы: