Safety  

2

For parts or assistance, call Master Plumber Customer Service at 

1-800-628-9439

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol. When you see this 

symbol on your pump or in this manual, look for one of 

the following signal words and be alert to the potential for 
personal injury.

warns about hazards that 

will cause serious 

personal injury, death or major property 

damage if ignored.

warns about hazards that 

can cause serious 

personal injury, death or major property 

damage if ignored.

warns about hazards that 

will or can cause 

minor personal injury or property damage if 

ignored.
The label 

NOTICE indicates special instructions which are 

important but not related to hazards.
Carefully read and follow all safety instructions in this 

manual and on pump.
Keep safety labels in good condition.  

Replace missing or damaged safety labels.

GENERAL SAFETY

1.  To avoid risk of serious bodily injury and property 

damage, read the safety instructions carefully before 

installing this pump.

2.  Follow local and/or national plumbing  and electrical 

codes when installing the pump.

3. 

Hazardous Pressure. The pump body may 

explode if used as a booster pump unless 

a relief valve capable of passing the full pump flow at 

100 PSI (689 kPa) is installed. Never run the pump dry. 

To do so can damage internal parts, overheat pump 

(which can cause burns to people handling or servicing 

pump), and will void warranty!

4. 

Risk of fire or explosion. To avoid risk of 

fire and explosion, 

Pump Water Only with 

this pump. Do not use this pump in an atmosphere that 

might contain flammable fumes or vapors.

5. 

Burn Hazard. If water is trapped in the 

pump during operation it may turn to 

steam. Trapped steam can lead to explosion and burns. 

Never run the pump with the outlet closed or obstructed. 

6.  If used with a well for potable water, always dis in fect  

the well and test the water for purity before using.  

Check with your local health de part ment for testing  

pro ce dures.

7.  Complete pump and piping must be protected against 

freezing. Freezing will cause damage and void the 

warranty.

8.  This pump is not designed, nor intended, for the 

pumping of chemicals or corrosive liquids. Pump water 

only with this pump.

9.  Do not run pump dry. If the pump is dry, damage will 

result and void the warranty.

ELECTRICAL SAFETY

The pump is supplied with a 3-conductor grounding 

type cord. Connect only to a properly grounded, GFCI 

protected outlet. Do not lift the pump by the electrical cord.

Match the motor voltage and the power supply 

voltage. The supply voltage must be /- 10% of 

the motor nameplate voltage.  Incorrect voltage can cause 

fire or seriously damage the motor and will void the 

warranty. If in doubt, consult a licensed electrician.

The pump is non-submersible. Keep the motor dry at 

all times.  Do not wash the motor.  Do not immerse.  

Protect the motor from wet weather.

If using an extension cord, use only a UL approved 

indoor/outdoor, 3-wire, grounding type cord.  Do not 

allow any part of the cord or the receptacle ends to sit in 

water or in damp locations.

Unplug the pump before servicing. To avoid fatal 

shocks, proceed as follows if the pump needs  

servicing.

A. 

Disconnect the power  

  to the pump outlet box  

  before pulling the  

  pump plug. Modern  

 

motors are designed  

 

to operate at high  

 

temperatures. To avoid  

 

burns when servicing  

 

pump, allow it to cool  

 

for 20 minutes after  

 

shut-down before  

 handling.
B. 

Take extreme care  

  when changing fuses.  

To reduce the chance of fatal electrical shocks, DO NOT 

stand in water or put your finger in the fuse socket.

C. 

Ground the pressure switch or motor before before 

running this pump.

D. 

Plug pump into a Ground Fault Circuit Interrupter (GFCI) 

protected grounded outlet only.

WARNING

Hazardous voltage. Can shock, 

burn, or cause death.

Ground pump before connecting 

to power supply. Disconnect 

power before working on pump, 

motor or tank.

WARNING

Hazardous pressure!  

Install pressure relief  

valve in discharge pipe.

Release all pressure on  

system before working on  

any component.

Содержание 123343

Страница 1: ...eration Parts For further operating installation or maintenance assistance Call 1 800 628 9439 ESPAÑOL PÁGINAS 8 13 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 1 800 628 9439 Model 123343 2018 TRU590 09 17 18 Chicago IL 60631 Phone 1 800 628 9439 www masterplumberpump com ...

Страница 2: ...sing Check with your local health de part ment for testing pro ce dures 7 Complete pump and piping must be protected against freezing Freezing will cause damage and void the warranty 8 This pump is not designed nor intended for the pumping of chemicals or corrosive liquids Pump water only with this pump 9 Do not run pump dry If the pump is dry damage will result and void the warranty ELECTRICAL SA...

Страница 3: ...ump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Twenty Four 24 Month Limited Warranty Product Warranty Period Drill Pump 90 Days MiniVac Pump 12 Volt MiniVac Pump Engine Drive Self Priming Pump Jet Pumps Jet Pump and Tank System Sprinkler Pumps 1 Year Portable Transfer Pump 4 Submersible Well Pumps 3 Y...

Страница 4: ...persons handling the pump Running pump without water can damage the impeller and may damage the seal causing leaking or flooding and will void the warranty Fill the pump with water before starting it Follow the steps below 1 Remove the priming plug 2 Make sure the suction and the discharge valves and any hoses on the discharge side of the pump are open 3 Fill the pump and suction pipe with water 4...

Страница 5: ...harge The pump can supply up to 3 4 sprinklers depending on GPM output of the sprinklers Electrical Hazardous voltage Risk of dangerous or fatal electric shock Plug the pump into a 115 Volt 60 Cycle Ground Fault Circuit Interrupter GFCI protected grounded outlet only The pump is equipped with a 3 wire grounded cord and plug Do not modify or remove the plug Make sure the pump circuit meets the Nati...

Страница 6: ...tions on suction line and shaft seal with soapy water 2 Water level below suction pipe inlet 2 Lower suction line into water and re prime If receding water level in well exceeds 25 7 6M a deep well pump is needed Impeller is plugged Clean impeller Foot valve is stuck shut Replace the foot valve Pipes are frozen Thaw pipes Foot valve and or strainer are Raise the foot valve and or strainer above bo...

Страница 7: ...P0170 11 Handle 1 101P1450 12 Washer Handle 1 121P1500 13 Screw Handle 1 121P1600 14 Lock Nut Handle 1 121P0950 15 Water Singer 1 102P0540 16 Handle Grip Handle 1 102P1650 17 Fan Cooling 1 102P0570 18 Fan Cover 1 721S1090 19 Power Cord 1 191P0560 20 Screws Capacitor Holder 11 121P2060 21 Grounding Lug 1 171P4070 22 Capacitor Box W Cover 1 102P2830 23 Capacitor 1 171P5430 24 O Ring Capacitor Box 1 ...

Страница 8: ...ocal 7 Tanto la bomba como los tubos deben estar protegidos contra heladas Las heladas provocarán daños y anularán la garantía 8 Esta bomba no ha sido diseñada ni concebida para bombear sustancias químicas o líquidos corrosivos Bombee sólo agua con esta bomba 9 No deje marchar la bomba en seco Si la bomba está seca ocurrirán daños y la garantía quedará anulada SEGURIDAD ELÉCTRICA La bomba viene pr...

Страница 9: ...os fines de la garantía devuelva la etiqueta del cordón de la bomba y el recibo de compra original a la tienda minorista Descarte la bomba cumpliendo con todas las normas locales que correspondan para su eliminación Excepciones para la Garantía Limitada de veinticuatro 24 Meses Producto Período de garantía Bomba a taladro 90 días Bomba MiniVac Bomba MiniVac de 12 voltios Bomba autocebadora a motor...

Страница 10: ...undaciones y la garantía quedará anulada Llene la bomba con agua antes de activarla Siga los pasos siguientes 1 Saque el tapón de cebadura 2 Asegúrese de que las válvulas de aspiración y de descarga y toda manguera del lado de la descarga de la bomba estén abiertas 3 Llene la bomba y la tubería de aspiración con agua 4 Vuelva a colocar el tapón de cebadura usando cinta de teflón en la rosca apriet...

Страница 11: ...res Información eléctrica Tensión peligrosa Riesgo de choque eléctrico peligroso o fatal Enchufe la bomba solamente en un tomacorriente de 115 60 de ciclo conectado a tierra y protegido por un disyuntor de escape a tierra GFCI La bomba viene equipada con un cordón y enchufe trifilar con conexión a tierra No modifique ni saque el enchufe Asegúrese de que el circuito de la bomba cumpla con las norma...

Страница 12: ...debajo de la 2 Baje la línea de aspiración dentro del agua y vuelva a cebar Si el nivel admisión de la tubería de aspiración del agua que se retira supera los 25 7 6 m se necesitará una bomba para pozos profundos El impulsor está obstruido Limpie el impulsor La válvula de pie está atascada en Reemplace la válvula de pie la posición cerrada Las tuberías están congeladas Descongele las tuberías La v...

Страница 13: ...21P1500 13 Tornillo Manija 1 121P1600 14 Contratuerca Manija 1 121P0950 15 Deflector del agua 1 102P0540 16 Agarradera de la manija Manija 1 102P1650 17 Ventilador refrigerante 1 102P0570 18 Cubierta del ventilador 1 721S1090 19 Cordón eléctrico 1 191P0560 20 Tornillos Soporte del capacitor 11 121P2060 21 Saliente de puesta a tierra 1 171P4070 22 Caja del capacitor con cubierta 1 102P2830 23 Capac...

Страница 14: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 15: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 16: ......

Отзывы: