UltraTemp
®
Heat Pump Installation and User’s Guide
13
Connecting the Heat Pump to the IntelliTouch
®
or EasyTouch
®
Load Center via the
Heat Pump Spade Terminals
To connect the heat pump cable to the Personality Board in the IntelliTouch
®
or EasyTouch
®
Load Center:
1. Turn off the main system power before making any connections.
2. Unlatch the front door spring latches, and open the front door of the IntelliTouch
®
or EasyTouch
®
Load Center.
3. Loosen the two retaining screws from the top of the control panel and lower the control panel down
to access the Personality Board.
4. Run a UL approved conductor cable from the UltraTemp
®
to the Load Center.
5. Route the cable up through the low voltage raceway located on the left of the Load Center to the
Personality Board, see
Figure 12
.
6. Insert
the
UltraTemp
®
cable plug onto the gas heater terminal connector, located on the left side of
the Personality Board.
7. If the heat pump is used in conjunction with a gas heater, use a 520403 Dual Heater Relay Kit.
Plug the heat pump relay connector onto the SOLAR Terminal on the top center of the Personality
Board. Follow the Dual Heater Relay Kit instructions for further set-up details. Be sure to install
solar temperature sensor as per instructions.
8. Lift the control panel up into position and secure with the two screws.
9. Connect the cable from the IntelliTouch
®
or EasyTouch
®
Load Center to the heat pump remote control
terminals using ¼ in. “Spade” connectors, see
Figure 11
on the previous page. Follow instructions
for wiring on
page 12
.
NOTE:
Solar temperature sensor could be left loose in load center. The automation system does not use
the temperature reading but just looks for resistance.
Figure 12.
COMMUNICATION PORT
Pin Configuration for connecting IntelliFlo to IntelliTouch:
Strip back the cable conductors 1/4”. Insert the two wires into either of the
COM PORTS
(
J7
and
J8
) screw terminals. Secure the wires with the screws.
Note:
Multiple wires may be inserted into a single screw terminal.
A communication expansion module with 3 extra COM ports and 4 IntelliFlo
pump ports is available (P/N 520818).
• IntelliFlo: Connect pin 6 (green) to IntelliTouch screw terminal pin 2 (green)
• IntelliFlo: Connect pin 7 (yellow) to IntelliTouch screw terminal pin 3 (yellow)
IntelliFlo
®
Cable Pin Configuration
IntelliTouch
Screw Terminal
COM PORT (J7 / J8)
Pin 7
(Yellow)
Pin 6
(Green)
1
2
3
4
BLK
GRN
YEL
RED
A disconnecting
means must be
located within
sight from the
equipment and
at least 5 feet
(1.52 m) from
the inside walls
of the pool, spa
or hot tub.
TEMP. SENSORS HAVE NO POLARITY.
RED/BLK WIRES ARE INTERCHANGEABLE.
INDOOR CONTROL
(AND/OR)
RF TRANSCEIVER
(AND/OR)
iS10
SPA-SIDE REMOTE.