Pentair Pool Products UltraTemp Скачать руководство пользователя страница 1

UltraTemp

®

Heat Pump

AHRI Performance Certifi ed

Installation

and

User's Guide

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

Содержание UltraTemp

Страница 1: ...UltraTemp Heat Pump AHRI Performance Certified Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS...

Страница 2: ...rsement between the proprietors of these names and brands and Pentair Water Pool and Spa Inc Those names and brands may be the trademarks or registered trademarks of those parties or others P N 474099...

Страница 3: ...ow Control Valve 8 Multiple Unit Installation 9 Heat Pump Heater and or Solar Combination 9 Multiple Heat Pump Connections 10 Electrical Connections 11 General Information 11 Main Power 11 Bonding 11...

Страница 4: ...rol Panel Alarm Messages 31 Heat Pump Wiring Diagram Single Phase 50 60 Hz 32 Heat Pump Wiring Diagram Three Phase 60 Hz 33 Heat Pump Wiring Diagram Three Phase 50 Hz 34 AutoSet Contactor to Mechanica...

Страница 5: ...pecific instructions inside this guide WARNING To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times WARNING For units intended for us...

Страница 6: ...ater temperature with an accurate thermometer Spa or hot tub thermostats may err in regulating water temperatures 5 Persons with a medical history of heart disease circulatory problems diabetes or blo...

Страница 7: ...commendsamaximumwatertemperatureof78 F 25 C Useanaccuratepoolthermometer Adifference of 4 F 2 C between 78 F and 82 F 26 C and 28 C will significantly increase energy consumption 2 Carefully monitor t...

Страница 8: ...for Pallet and Packaging COP Coefficient of Performance 90 110 120 120 H C 120C 100I 90I Voltage Phase Hz 208 230 1 60 208 230 1 60 208 230 1 60 208 230 1 60 208 230 3 60 230 1 50 380 400 3 50 Min Cir...

Страница 9: ...t heating It is not reasonable to expect a heat pump to perform like a gas heater which has a much higher BTU output and faster response Additionally gas heaters are not dependent on environmental con...

Страница 10: ...pool temperatures Automatic defrost feature senses refrigerant temperature and prevents the heat pump from freezing allowing the heat pump to operate at even lower temperatures Compatible with all au...

Страница 11: ...heat pump installations 1 Plumbing connections 2 inch 2 Level surface for proper drainage 3 Suitable electrical supply line See rating plate on unit for electrical specifications Ajunction box is not...

Страница 12: ...tely before continuing the installation Location CAUTION When pool equipment is located below the pool surface a leak from any component can cause large scale water loss or flooding Pentair Water Pool...

Страница 13: ...gh solid fence or other permanent barrier Canadian installations require a minimum of three 3 meters from pool water Roof Run off Make sure the heat pump is not located where large amounts of water ma...

Страница 14: ...the evaporator coils and electronics causing corrosion and hamper the efficiency If you are located within 15 miles of the coast salt may also be in the well water Anchor Clamp s Installation In Flori...

Страница 15: ...of water Be sure to provide an optional manual bypass valve between the pool and the heat pump outlet to protect from back siphoning Arrangement of pool system components other than Figure 6 and foll...

Страница 16: ...lastic piping PVC Schedule 40 should be connected to the heat pump The unions provided with the unit accept 2 in PVC pipe Automatic Flow Control Valve The inlet outlet header of the heat pump comes eq...

Страница 17: ...at pump may be used in conjunction with a gas or electric heater or any combination of heat sources including solar All heat sources must be plumbed in series to work correctly and efficiently A recom...

Страница 18: ...VC Pipe 2 PVC Pipe Flow Meter To Pool 3 Ball Valve Bypass Check Valves are optional on heater inlets but will help for system balancing 24 610 mm 2 PVC Pipe 2 PVC Pipe 2 PVC Pipe 3 PVC Pipe 3 PVC Pipe...

Страница 19: ...the electrical source Be sure the power to the circuit for the heat pump is turned off 1 Remove the front left panel of the heat pump cabinet you do not need to remove the torque head screw at the to...

Страница 20: ...el to the heat pump Remove the 4 bezel retaining screws from above the electrical compartment and rotate the bezel downward This will allow you to access the Remote terminals on the back of the heat p...

Страница 21: ...as per instructions 8 Lift the control panel up into position and secure with the two screws 9 ConnectthecablefromtheIntelliTouch orEasyTouch LoadCentertotheheatpumpremotecontrol terminals using in S...

Страница 22: ...rom heat pump board to the IntelliTouch or EasyTouch system is via the optional four wire cable P N 520199 To connect the heat pump board cable to the IntelliTouch or EasyTouch load center CAUTION Swi...

Страница 23: ...rdCOMPORTtotheRS 485IntelliTouch connection J8 on the Heat Pump control Board Connect the Green wire to J8 pin 2 and yellow wire to J8 pin 3 Do NOT use pin 1 red or pin 4 black wires The connections a...

Страница 24: ...o operate when the filter pump is off then the water pressure switch needs to be adjusted 5 Remove the heat pump s left front panel and remove remaining right front panel The water pressure switch is...

Страница 25: ...ining delay time in minutes and seconds Be sure that there is water in the pool and that the surface level is above the skimmer or other inlets of the pool s filter system The pool pump must be on and...

Страница 26: ...presses the use of the pool or spa set points will be toggled The operator can also toggle between the pool and spa set point by using the UP and DOWN arrows 4 UPand DOWNArrow buttons The UPand DOWN a...

Страница 27: ...after the letters SET in the lower left corner of the display The number after ACT on the bottom row is the actual measured water temperature b The set point need not be active to be adjusted Press th...

Страница 28: ...hen time expires Countdown time is in hours and minutes a To activate the heat pump timer press the MENU SELECT button repeatedly until the heat pump timer screen is displayed With that screen display...

Страница 29: ...without regard to the local set point However the high and low temperature faults are still active so the heat pump will not heat above 104 F or cool below 45 F To use the Serial Remote mode the Inte...

Страница 30: ...whichcanbeconnected to the pump to move water though the heat pump This allows the heat pump to sense the temperature of the body of water whose temperature is being maintained After a temperature sta...

Страница 31: ...and seconds See Defrost section on page 29 for more details 4 Pump Start Delay One to Four Hour timer used in conjunction with the AutoSet feature Counts down the time until the control board will ene...

Страница 32: ...d at the factory Menu appears only if a delay is active Menu appears only if defrost is enabled in the operator menu MENU SELECT MENU TREE POOL IDLE HEAT COOL SET __ ACT __ SPA IDLE HEAT COOL SET __ A...

Страница 33: ...red water temperature The Spa set point can be raised or lowered using the UP and DOWN arrows while this screen is displayed The display will automatically return to this screen after 15 seconds of pu...

Страница 34: ...e control board has the ability to store a 30Alarm history of previous alarms that have occurred At the alarm status screen press the DOWN arrow The first alarm will be the most recent alarm that has...

Страница 35: ...NHEIT CELSIUS PRESS POOL SPA TO EXIT SETUP WP HP LP PL SP 1 1 1 0 0 FAN COMP PMP REV 1 1 1 0 DEFROST ENABLE DISABLE WATER TEMP OFFSET OFFSET 2 TO 2 THE NUMBER ONE 1 IS DISPLAYED WHEN THE ASSOCIATED IN...

Страница 36: ...N arrows 4 Intell Address IntelliTouch RS 485 Communications Address which must match the address usedintheIntelliTouch orEasyTouch automationcontrollerbeingcommunicatedwith Adjustable from 1 to 16 us...

Страница 37: ...nel can be locked Once locked if any button is pressed the display will read To activate the control panel lockout press the MENU SELECT and POOL SPA buttons simultaneously To unlock the control panel...

Страница 38: ...minutes 3 Once the 4 hours has expired at 1 00 am the control board will energize the internal contactor in the heat pump to turn on your water circulation pump 4 The heat pump will sense water tempe...

Страница 39: ...rcuit shorted WATER THERM OPEN Water temperature thermistor circuit open SUCTION TH SHORT Defrost thermistor circuit shorted SUCTION TH OPEN Defrost thermistor circuit open BROWNOUT The 24 VAC supply...

Страница 40: ...E GREEN P U M P COM SPA POOL INPUT SWITCHES J9 WTR TEMP J4 DEF TEMP J5 3 WIRE REMOTE TERM PWR J7 RS 485 J8 INTELLITOUCH CONNECTION BLACK OUTPUTS J3 BLACK WHITE PURPLE BLACK BLACK Capacitor COMPR FAN F...

Страница 41: ...L INPUT SWITCHES J9 WTR TEMP J4 DEF TEMP J5 3 WIRE REMOTE TERM PWR J7 RS 485 J8 INTELLITOUCH CONNECTION BLACK OUTPUTS J3 BLACK PURPLE BLACK BLACK Capacitor Transformer 208V 240V 24 VAC COM Filter Pump...

Страница 42: ...RE REMOTE TERM PWR J7 J8 CONNECTION BLACK OUTPUTS J3 BLACK PURPLE BLACK BLACK Transformer 415V 24 VAC COM Compressor Contactor Fan Relay BLACK WHITE BLACK BLUE BLUE WHITE PURPLE ORANGE BLACK YELLOW BL...

Страница 43: ...matic T104 Timer CLOCK MOTOR 240V SUPPLY GROUND LINE 1 LINE 2 FILTER PUMP GROUND AutoSet Contactor A 1 2 3 4 NOTES 1 Mechanical timer is not provided with the heat pump 2 Example only other timers wil...

Страница 44: ...protect your pump filter and heat pump from the elements Perform the following steps to completely drain the heat pump see Figure 22 1 Turn off the electrical power to the heat pump at the main break...

Страница 45: ...vent corrosion and damage Use a deflector if needed 5 If the unit is installed under a very sharp roof pitch or under a roof without a gutter a gutter or diverter should be fitted to prevent excessive...

Страница 46: ...this heat exchange process the refrigerant is cooled and returned to the air coil and the cycle repeats NOTE The maximum heat output and efficiency of a heat pump is dependent upon the quality and pe...

Страница 47: ...Alarm The pressure switch sensing water flow is open 1 Water circulation pump not on Verify water circulation pump is on 2 Insufficient water flow Dirty or worn filters or clogged lint traps Verify fi...

Страница 48: ...ossibilities Low or restricted water flow through heater Dirty or worn filters or clogged lint traps Clogged filter pump impeller Improper plumbing valve settings Suction leak allowing air into the wa...

Страница 49: ...Board for LOW REFRIG Alarm The outside air temperature too low and Defrost feature is NOT enable Malfunctioning Defrost Thermistor Make sure heater is installed with the required placement clearances...

Страница 50: ...HMS F OHMS 0 85 387 51 19 377 66 13 136 81 9 076 96 6 382 10 62 479 52 18 870 67 12 809 82 8 861 97 6 238 20 46 225 53 18 377 68 12 491 83 8 651 98 6 097 30 34 561 54 17 899 69 12 182 84 8 447 99 5 96...

Страница 51: ...00 341 123 11 HP900 348 132 8 HP1200 360 131 6 HP1200R 360 131 6 UltraTemp 90 330 138 18 UltraTemp 110 337 153 9 UltraTemp 120 344 146 7 UltraTemp 120 H C 368 146 8 UltraTemp 120C 346 146 10 UltraTemp...

Страница 52: ...6 Replacement Parts UltraTemp Illustrated Parts 40 32 13 3 26 6 29 30 12 31 33 34 28 5 15 14 43 11 44 7 10 35 36 9 8 38 39 24 25 25 25 2 41 42 4 27 37 1 B DETAIL B Single Phase DETAIL B Three Phase 1...

Страница 53: ...t Right Model 100I only 473412 Panel Front Right Model 90I 90 474265 Panel Front Right Model 90 Black 21 22 23 24 5 6 11 17 18 ITEM PART NO DESCRIPTION 470159 Screw 10 x 75 Pan Head Phillips Almond 47...

Страница 54: ...46 UltraTemp Heat Pump Installation and User s Guide NOTES...

Страница 55: ...NOTES SAVE THESE INSTRUCTIONS...

Страница 56: ...P N 474099 Rev E 9 27 11...

Отзывы: