To avoid unneeded service calls, prevent possible injuries,
and get the most out of your pump, READ THIS MANUAL
CAREFULLY!
The Sta-Rite ‘CF6’ Series Self-Priming Centrifugal Pump:
• Is designed for use with swimming pools or as a 

centrifugal pump.

• Is an excellent performer; durable, reliable.

Table of Contents

Safety Instructions  ........................................................2
Installation.................................................................3-4
Electrical ...................................................................4-5
Operation.....................................................................6
Storage/Winterizing ...................................................6-7
Pump Service ............................................................7-8
Troubleshooting Guide .................................................9
Repair Parts List ..........................................................10
Warranty ....................................................................12

Technical Support

Sanford, North Carolina
(8 A.M. to 5 P.M. EST)

Moorpark, California
(8 A.M. to 5 P.M. PST)

Phone: (800) 831-7133

Fax: (800) 284-4151

www.pentairpool.com www.staritepool.com

READ AND FOLLOW SAFETY 
INSTRUCTIONS!

This is the safety alert symbol. When you see this
symbol on your system or in this manual, look for one

of the following signal words and be alert to the potential
for personal injury.

warns about hazards that 

will

cause death, 

serious personal injury, or major property damage if ignored.

warns about hazards that 

can

cause death, 

serious personal injury, or major property damage if ignored.

warns about hazards that 

will

or 

can

cause

minor personal injury or property damage if ignored.

NOTICE

indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this 
manual and on equipment. 

Keep safety labels in good 

condition; replace if missing or damaged.

Incorrectly installed or tested equipment 
may fail, causing severe injury or property
damage. 

Read and follow instructions in owner's manual when 
installing and operating equipment. Have a trained pool
professional perform all pressure tests.
1. Do not connect system to a high pressure or city water

system.

2. Use equipment only in a pool or spa installation.
3. Trapped air in system can cause explosion. BE SURE 

all air is out of system before operating or testing 
equipment.

Before pressure testing, make the following safety checks:

Check all clamps, bolts, lids, and system accessories before
testing.
Release all air in system before testing.
Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-m) torque for
testing.
Water pressure for test must be less than 25 PSI (7.5 kg/cm

2

).

Water Temperature for test must be less than 100° F. (38° C).
Limit test to 24 hours. After test, visually check system to be
sure it is ready for operation. Remove trap lid and retighten
hand tight only.

NOTICE:

These parameters apply to Sta-Rite equipment

only. For non-Sta-Rite equipment, consult manufacturer.

IMPORTANT
SAFETY INSTRUCTIONS

Always follow basic safety precautions with this
equipment, including the following.

To reduce the risk of injury, do not per-

mit children to use this product unless they are closely
supervised at all times.

This pump is for use with permanently

installed pools and may also be used with hot tubs and
spas if so marked. Do not use with storable pools. A
permanently installed pool is constructed in or on the
ground or in a building such that it cannot be readily
disassembled for storage. A storable pool is con-
structed so that it may be readily disassembled for stor-
age and reassembled to its original integrity.

SAVE THESE INSTRUCTIONS

Содержание Sta-Rite CF6 Series

Страница 1: ...5 553 5000 Sta Rite and Pentair Water Pool and Spa are registered trademarks of Pentair Water Pool and Spa Inc and or its affiliated companies in the United States and or other countries Unless noted names and brands of others that may be used in this document are not used to indi cate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa In...

Страница 2: ...e injury or property damage Read and follow instructions in owner s manual when installing and operating equipment Have a trained pool professional perform all pressure tests 1 Do not connect system to a high pressure or city water system 2 Use equipment only in a pool or spa installation 3 Trapped air in system can cause explosion BE SURE all air is out of system before operating or testing equip...

Страница 3: ...s near the pump To avoid a strain left by a gap at the last connection start all piping at the pump and run pipe away from the pump Never use a suction pipe smaller than pump suction connection To avoid airlocking slope suction pipe slightly upward toward the pump NOTICE To prevent flooding when removing pump for service all flooded suction systems must have gate valves in suction and discharge pi...

Страница 4: ...latest ASME ANSI Specification for Suction Fittings For Use in Swimming Pools Spas Hot Tubs and Whirlpool Bathtub Applications ELECTRICAL Hazardous voltage Can shock burn or cause death Ground pump before connecting to power supply Ground motor before connecting to electrical power supply Failure to ground pump motor can cause serious or fatal electrical shock hazard Do not ground to a gas supply ...

Страница 5: ...and test procedures for GFCI see manufacturer s instruction In case of power outage check GFCI for tripping which will prevent normal pump operation Reset if necessary NOTICE If you do not use conduit when wiring motor be sure to seal wire opening on end of motor to prevent dirt bugs etc from entering NOTICE Three phase models require magnetic motor starters and extenal overload protection If in d...

Страница 6: ...ction piping If pump does not prime make sure that all valves are open suction pipe end is under water and that there are no leaks in suction pipe See Troubleshooting Guide Page 9 STORAGE WINTERIZING Allowing pump to freeze will damage pump and void warranty Do not use anti freeze solutions except propylene glycol in your pool spa system Propylene glycol is non toxic and will not damage plastic sy...

Страница 7: ...eded beyond reasonable care and periodic cleaning If shaft seal is worn or damaged repair as follows Pump Disassembly Disconnect power to pump motor Be sure gate valves on suction and return piping are closed before starting work Release all pressure by opening all vents before starting work 1 Drain pump by removing drain plugs on bottom of pump body and trap body 2 Be sure there is no pressure in...

Страница 8: ...on motor and tighten capscrews Key No 5 2 Make certain seal faces are clean Hold the motor shaft extension stationary and tighten impeller on to shaft NOTICE 3 Phase models use an impeller screw For these models install the impeller washer and lock screw left hand thread turn counterclockwise before proceeding to Step 3 3 Leaving volute gasket off place volute on adapter and tighten nuts Key No 11...

Страница 9: ...ORN IMPELLER 1 Make sure suction trap is not clogged if it is clean trap and strainer 2 Make sure impeller is not clogged follow instructions under Removing Old Seal Page 7 check impeller for clogging follow instructions under Installing New Seal Page 7 for reassembly 3 Impeller may be worn If so order replacement parts from Repair Parts List Page 10 4 Pump may be trying to push too high a column ...

Страница 10: ... C20 72 C20 72 C20 72 C20 72 9 Volute Trap Body 1 C1 201DB C1 201DB C1 201DB C1 201DB 10 Pipe Plug 1 4 NPT 2 U78 57DT U78 57DT U78 57DT U78 57DT 11 Stud 3 8 16 x 1 7 16 4 U30 36SS U30 36SS 11 Stud 3 8 x 1 1 4 4 U30 22SS U30 22SS 11A Nut 3 8 16 4 U36 38SS U36 38SS U36 38SS U36 38SS 12 Trap Cover 1 C3 78D C3 78D C3 78D C3 78D 13 Cord Ring 1 U9 46 U9 46 U9 46 U9 46 14 Trap Handle 2 C154 25 C154 25 C1...

Страница 11: ...11 ...

Страница 12: ...y Requests for warranty service must be made through the installing dealer This warranty shall not apply to any product that has been subject to negligence misapplication improper installation or maintenance or other circumstances which are not in Pentair Water Pool and Spa s direct control Failure to have product installed by a professional in compliance with local codes will void any and all man...

Отзывы: