TROUBLESHOOTING 

 

RUN LIGHT

 

CAL. LIGHT

 

PROBLEM or FUNCTION

 

CORRECTIVE ACTION

 

On Steady 

Off 

RUN: 

Pump is running—or ready to run—
no problems in operation 

None  

On Steady 

On Steady 

CAL:

  

The Submersible Pump Protector 
is in the calibration process. 

None 

Off On 

Steady 

CAL COMPLETE:

The Submersible Pump Protector 
is calibrated; the 

RESTART 

DELAY/ CALIBRATION

 knob was 

left in the 

CAL.

 position. Pump is 

off. 

Pump will restart as soon as 
the 

RESTART DELAY/ 

CALIBRATION

 knob is rotated 

out of the 

CAL.

 position. 

Off Off 

OFF / MANUAL RESTART:  

The pump is not running. Either the 
Submersible Pump Protector has 
tripped on dry-run, dead-head, or 
overcurrent while the 

RESTART 

DELAY/ CALIBRATION

 knob was 

in the 

RESET

 position or source 

power is not present. 

If knob is in the 

RESET

 

position, rotate out of 

RESET

If the 

CAL.

 light blinks, check 

for an overcurrent condition. If 
the 

RUN

 light blinks, look for a 

dry-run or dead-head condition. 
If no lights come on, check 
incoming power for adequate 
voltage. 

Blinking Off 

DRY RUN / DEAD HEAD:

 

The Submersible Pump Protector 
has shut the pump off due to a dry-
run or dead- head condition.  The 
unit is timing through the restart 
delay and will try to restart. 

Check for restricted flow or 
inadequate supply of liquid. 
 

Off Blinking 

OVERCURRENT:

 

The Submersible Pump Protector 
has shut the pump off due to an 
overcurrent condition. The unit is 
timing through the restart delay and 
will try to restart if line voltage is at 
an acceptable level. 

Check for low or high voltage 
or jammed pump impellers. If 
these conditions do not exist, 
recalibrate the unit while it is 
drawing higher current (amps 
should not exceed SFA). 

Blinking 

alternately 

with the 

CAL. LIGHT

 

Blinking  

alternately 

with the 

RUN LIGHT

 

VOLTAGE FAULT:

The Submersible Pump Protector 
is preventing the pump from 
starting due to voltage problems. 
The voltage is being interrogated 
and the unit will remain in this 
mode until the voltage is at an 
acceptable level. 

If the unit remains in this state 
for more than 5 seconds, check 
for high or low voltage. 

Blinking in 

unison with 

the 

CAL. 

LIGHT

 

Blinking in 

unison with 

the 

RUN 

LIGHT

 

RAPID CYCLE

The Submersible Pump Protector 
has shut down on rapid cycling. 
Power must be removed and 
reapplied to reset the unit.

 

Check for a broken bladder in 
the pressure tank (if used), or 
check for a defective pressure 
or float switch. 

 

Содержание Pentek SPP-235P

Страница 1: ...INSTALLATION INSTRUCTIONS Submersible Pump Protector MODEL SPP 235P II_SPP 235P_A1 293 Wright Street Delavan WI 53115 866 9 PENTEK...

Страница 2: ...ontrol box If the location is wet or dusty a NEMA 3R 4 or 12 enclosure should be used The Submersible Pump Protector must be protected by a fuse or circuit breaker 2 Connect a current transformer CT t...

Страница 3: ...Size Current CT 5 7 HP 27 5 42 1 50 5 10 HP 51 75 5 15 HP 75 100 5 TABLE 1 Current Transformer Selection FIGURE NO 1 Typical Wiring Diagram 3...

Страница 4: ...4...

Страница 5: ...he RESTART DELAY CALIBRATION knob to CAL while pumping Wait for the pump to turn off approximately 10 seconds then adjust the RESTART DELAY CALIBRATION knob to the desired setting SENSITIVITY The Subm...

Страница 6: ...60 second period The Submersible Pump Protector is capable of detecting a rapid cycle condition whether a control device such as a pressure switch is installed before or after it Upon detecting eithe...

Страница 7: ...Submersible Pump Protector remove and re apply power Note Protection against rapid cycling of a control device installed after the Submersible Pump Protector is always enabled Disabling line side det...

Страница 8: ...e to a dry run or dead head condition The unit is timing through the restart delay and will try to restart Check for restricted flow or inadequate supply of liquid Off Blinking OVERCURRENT The Submers...

Страница 9: ...PHYSICAL DIMENSIONS 4 05 102 87 5 26 133 60 4 50 114 30 375 9 53 2 93 74 42 FRONT VIEW 2 17 55 12 2 90 73 66 BOTTOM VIEW 9...

Страница 10: ...age 230VAC Load Range 5 to 15hp external current transformer required Frequency 50 60 Hz note 50Hz will increase all delay timers by 20 Output Characteristics Output Contact Rating SPST 720VA 240VAC G...

Страница 11: ...11 NOTES...

Страница 12: ...ure provided such goods have not been subjected to misapplication misuse negligence or repairs by unauthorized persons This Warranty does not apply to any faulty performance caused by improper voltage...

Отзывы: